Sucheta Tamragouri
Research Subjects
Sucheta Tamragouri has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Zhenglun Alan Wei
Department of Biomedical Engineering, Worcester Polytechnic Institute 1 , Worcester, Massachusetts 01609
2 shared publications - Biao Si
Department of Biomedical Engineering, Worcester Polytechnic Institute 1 , Worcester, Massachusetts 01609
1 shared publication - Maduka Maduka
Department of Biomedical Engineering, Worcester Polytechnic Institute 1 , Worcester, Massachusetts 01609
1 shared publication - Pritom Saha
Department of Biomedical Engineering, Worcester Polytechnic Institute 1 , Worcester, Massachusetts 01609
1 shared publication - Zhongqiang Zhang
Department of Mathematical Sciences, Worcester Polytechnic Institute, Worcester, MA 01609 USA
1 shared publication
Latest Publications
- 1 June 2026
- Published by AIP Publishing in Physics of Fluids
- Vol. 38 (6)
Systematic investigation of flow stasis quantification in separated flows using a backward-facing step benchmark
Flow stasis is a major hemodynamics determinant of thrombosis associated with flow separation in the cardiovascular system. Residence time provides a quantitative measure of flow stasis and can serve as a surrogate transport metric associated with thrombogenic potential. However, the experimental parameters governing reliable dye-based residence time quantification, including injection location, injection rate, and imaging configuration, remain insufficiently defined, particularly in milli-scale models. This study establishes a standardized and reproducible framework for residence time quantification using a backward-facing step geometry, a canonical benchmark that reproduces physiologically relevant separated flow structures. An in-house image processing algorithm was developed to quantify residence time from dye washout. Injection location, injection rate, and imaging modality were systematically varied under steady and pulsatile inflow conditions spanning laminar, transitional and turbulent regimes (Reynolds number 100–3000). Both profile and en face imaging were evaluated to replicate clinically relevant viewing perspectives. Systematic testing identified an optimal injection window (IHL = 0.5, 0.25 ≤ ILL ≤ 0.5) and injection rate of 0.2 ml/min that minimized flow disturbance and produced <5% trial-to-trial variability. Positioning the injection within this window introduced dye into the persistent low-velocity core of the recirculation region, enabling consistent dye retention and saturation across all flow regimes. Optimal borescope placement (IHL = 1 and ILL = 0.75) produced the smallest relative differences between imaging configurations. This work defines critical experimental parameters for reproducible dye-based residence time quantification, enabling characterization of dye-washout behavior and flow stasis conditions associated with thrombogenic potential in millimeter-scale models.
- 1 June 2026
- Published by AIP Publishing in Physics of Fluids
- Vol. 38 (6)
Systematic investigation of flow stasis quantification in separated flows using a backward-facing step benchmark
Flow stasis is a major hemodynamics determinant of thrombosis associated with flow separation in the cardiovascular system. Residence time provides a quantitative measure of flow stasis and can serve as a surrogate transport metric associated with thrombogenic potential. However, the experimental parameters governing reliable dye-based residence time quantification, including injection location, injection rate, and imaging configuration, remain insufficiently defined, particularly in milli-scale models. This study establishes a standardized and reproducible framework for residence time quantification using a backward-facing step geometry, a canonical benchmark that reproduces physiologically relevant separated flow structures. An in-house image processing algorithm was developed to quantify residence time from dye washout. Injection location, injection rate, and imaging modality were systematically varied under steady and pulsatile inflow conditions spanning laminar, transitional and turbulent regimes (Reynolds number 100–3000). Both profile and en face imaging were evaluated to replicate clinically relevant viewing perspectives. Systematic testing identified an optimal injection window (IHL = 0.5, 0.25 ≤ ILL ≤ 0.5) and injection rate of 0.2 ml/min that minimized flow disturbance and produced <5% trial-to-trial variability. Positioning the injection within this window introduced dye into the persistent low-velocity core of the recirculation region, enabling consistent dye retention and saturation across all flow regimes. Optimal borescope placement (IHL = 1 and ILL = 0.75) produced the smallest relative differences between imaging configurations. This work defines critical experimental parameters for reproducible dye-based residence time quantification, enabling characterization of dye-washout behavior and flow stasis conditions associated with thrombogenic potential in millimeter-scale models.
- 1 January 2026
- Published by AIP Publishing in Physics of Fluids
- Vol. 38 (1)
Evaluation of reduced-order models for pulsatile flow over a two-dimensional backward-facing step
Reduced-order modeling (ROM) enables efficient analysis of unsteady separated flows, but most formulations are assessed under steady or purely periodic forcing and do not reflect physiologically realistic pulsatility. Here, two-dimensional backward-facing step simulations are performed under sinusoidal inflow and a physiologically inspired pulsatile waveform with intermittent bursts, including a sinusoidal control case matched to the pulsatile inflow in both frequency and amplitude. Proper orthogonal decomposition (POD) and dynamic mode decomposition (DMD) are applied to velocity and out-of-plane vorticity fields, and reconstruction accuracy and compactness are quantified, including DMD-I and DMD-E mode-ranking variants. In all cases, coherent vortices form downstream of the step due to separated shear-layer roll-up consistent with Kelvin–Helmholtz shear-layer dynamics. The forcing frequency and its harmonics are present in the modal spectra for all cases; however, cycle-to-cycle instantaneous fields are not identical, indicating organized dynamics without strict phase locking. Under pulsatile inflow, vortex interactions intensify through co-rotation, deformation, and merging, and an additional low-frequency component near 0.29 Hz appears across higher modes, consistent with slow modulation associated with waveform intermittency. POD provides the most robust balance of compression and accuracy, whereas DMD performs well for sinusoidal inflow but exhibits practical error plateaus around 10% under pulsatile forcing despite improved ranking strategies. Overall, waveform shape and intermittency increase effective flow dimensionality and challenge global linear ROMs, highlighting the need for localized or time-windowed reduction strategies to enable mechanistic insight in pulsatile biomedical flows and cardiovascular applications.
- 1 January 2026
- Published by AIP Publishing in Physics of Fluids
- Vol. 38 (1)
Evaluation of reduced-order models for pulsatile flow over a two-dimensional backward-facing step
Reduced-order modeling (ROM) enables efficient analysis of unsteady separated flows, but most formulations are assessed under steady or purely periodic forcing and do not reflect physiologically realistic pulsatility. Here, two-dimensional backward-facing step simulations are performed under sinusoidal inflow and a physiologically inspired pulsatile waveform with intermittent bursts, including a sinusoidal control case matched to the pulsatile inflow in both frequency and amplitude. Proper orthogonal decomposition (POD) and dynamic mode decomposition (DMD) are applied to velocity and out-of-plane vorticity fields, and reconstruction accuracy and compactness are quantified, including DMD-I and DMD-E mode-ranking variants. In all cases, coherent vortices form downstream of the step due to separated shear-layer roll-up consistent with Kelvin–Helmholtz shear-layer dynamics. The forcing frequency and its harmonics are present in the modal spectra for all cases; however, cycle-to-cycle instantaneous fields are not identical, indicating organized dynamics without strict phase locking. Under pulsatile inflow, vortex interactions intensify through co-rotation, deformation, and merging, and an additional low-frequency component near 0.29 Hz appears across higher modes, consistent with slow modulation associated with waveform intermittency. POD provides the most robust balance of compression and accuracy, whereas DMD performs well for sinusoidal inflow but exhibits practical error plateaus around 10% under pulsatile forcing despite improved ranking strategies. Overall, waveform shape and intermittency increase effective flow dimensionality and challenge global linear ROMs, highlighting the need for localized or time-windowed reduction strategies to enable mechanistic insight in pulsatile biomedical flows and cardiovascular applications.