Zihan Jin
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Zihan Jin has a total of 33 co-authors. Here are the top co-authors by number of shared publications:
- Dong Song
University of Southern California
4 shared publications - Zhouxiao Lu
University of Southern California
3 shared publications - Ellis Meng
University of Southern California
2 shared publications - Kee Scholten
University of Southern California
2 shared publications - Yingyi Gao
University of Southern California
2 shared publications - Alberto Esteban Linares
Department of Mechanical Engineering, Vanderbilt University, Nashville, Tennessee 37235, United States
1 shared publication
Latest Publications
- Open Access
- 25 September 2026
- Published by IOP Publishing in Journal of Neural Engineering
- Vol. 23 (5) , 056035
Chronic subthreshold rTMS transiently disrupts learning but enhances memory and flexibility in healthy rats
Objective. Repetitive transcranial magnetic stimulation (rTMS) is an emerging non-invasive neuromodulation technique with therapeutic potential for the treatment of cognitive disorders. However, its effects on fundamental learning and memory processes in the healthy brain remain poorly understood. We have previously shown that subthreshold rTMS delivered with a miniaturized coil modulates neuronal activities and evoked potentials, but whether these physiological effects translate into cognitive changes remains unknown. Here, we systematically characterize the effects of subthreshold rTMS on learning and memory in healthy rats. Approach. We examined both chronic and acute effects of high-frequency (10 Hz) subthreshold rTMS on spatial learning, memory, and cognitive flexibility in healthy rats performing the Barnes maze task. The stimulation was delivered to the prefrontal cortex using the miniaturized coil, whose focal design operates at subthreshold intensity. Main results. We found that chronic rTMS transiently disrupted early spatial learning during the acquisition phase but did not impair overall task performance. In contrast, rTMS was associated with enhanced cognitive flexibility during the first reversal-learning phase and strengthened spatial memory of prior target locations during acquisition and reversal probe trials. These effects were not detected in the exploratory second reversal phase, and no acute cognitive effects were detected under alternating rTMS and sham stimulation. Together, these findings suggest complex, phase-specific effects of subthreshold rTMS on rodent cognition: transiently hindering early learning while promoting memory retention and flexibility. Significance. This work highlights both the opportunities and challenges of rTMS for cognitive modulation and provides a translational framework for optimizing stimulation protocols in neuropsychiatric and neurodegenerative disorders.
- 25 September 2026
- Published by IOP Publishing in Journal of Neural Engineering
- Vol. 23 (5) , 056035
Open AccessChronic subthreshold rTMS transiently disrupts learning but enhances memory and flexibility in healthy rats
Objective. Repetitive transcranial magnetic stimulation (rTMS) is an emerging non-invasive neuromodulation technique with therapeutic potential for the treatment of cognitive disorders. However, its effects on fundamental learning and memory processes in the healthy brain remain poorly understood. We have previously shown that subthreshold rTMS delivered with a miniaturized coil modulates neuronal activities and evoked potentials, but whether these physiological effects translate into cognitive changes remains unknown. Here, we systematically characterize the effects of subthreshold rTMS on learning and memory in healthy rats. Approach. We examined both chronic and acute effects of high-frequency (10 Hz) subthreshold rTMS on spatial learning, memory, and cognitive flexibility in healthy rats performing the Barnes maze task. The stimulation was delivered to the prefrontal cortex using the miniaturized coil, whose focal design operates at subthreshold intensity. Main results. We found that chronic rTMS transiently disrupted early spatial learning during the acquisition phase but did not impair overall task performance. In contrast, rTMS was associated with enhanced cognitive flexibility during the first reversal-learning phase and strengthened spatial memory of prior target locations during acquisition and reversal probe trials. These effects were not detected in the exploratory second reversal phase, and no acute cognitive effects were detected under alternating rTMS and sham stimulation. Together, these findings suggest complex, phase-specific effects of subthreshold rTMS on rodent cognition: transiently hindering early learning while promoting memory retention and flexibility. Significance. This work highlights both the opportunities and challenges of rTMS for cognitive modulation and provides a translational framework for optimizing stimulation protocols in neuropsychiatric and neurodegenerative disorders.
- Open Access
- 12 August 2026
- Published by IOP Publishing in Progress in Biomedical Engineering
- Vol. 8 (3) , 032011
Design of conformal planar penetrating multi-electrode arrays for recording multiple brain regions
Simultaneous recording of neural activity across multiple interacting brain regions is a central objective in systems neuroscience and neural engineering. Penetrating multi-electrode arrays (MEAs) are essential for this purpose, yet their performance is fundamentally constrained by the complex three-dimensional anatomy of the brain and by substantial variability across species and brain regions. As a result, fixed or generic MEA designs, with periodic electrode distribution, often provide limited spatial coverage and suboptimal recording efficiency. In this work, we present a systematic design framework for conformal planar penetrating MEAs that explicitly links neuroanatomical constraints to key engineering decisions, including probe geometry, shank arrangement, electrode distribution, and implantation strategy. The framework integrates anatomical analysis, surgical considerations, device prototyping, electrophysiological validation, and histological verification within an iterative workflow, enabling progressive refinement from initial concept to final design. We illustrate this approach through representative case studies with an initial emphasis on hippocampal arrays, where highly curved and layered cytoarchitecture presents stringent design challenges, and subsequent extensions to other brain regions and animal models. These examples demonstrate how anatomy-aware, conformal designs can improve access to targeted neural structures and enable multi-region recordings. Overall, this work provides a practical, generalizable methodology for designing conformal planar penetrating MEAs. The proposed framework complements existing high-density and/or flexible probes, offering a unifying perspective for developing anatomically tailored neural recording technologies for basic neuroscience research and future translational applications.
- 12 August 2026
- Published by IOP Publishing in Progress in Biomedical Engineering
- Vol. 8 (3) , 032011
Open AccessDesign of conformal planar penetrating multi-electrode arrays for recording multiple brain regions
Simultaneous recording of neural activity across multiple interacting brain regions is a central objective in systems neuroscience and neural engineering. Penetrating multi-electrode arrays (MEAs) are essential for this purpose, yet their performance is fundamentally constrained by the complex three-dimensional anatomy of the brain and by substantial variability across species and brain regions. As a result, fixed or generic MEA designs, with periodic electrode distribution, often provide limited spatial coverage and suboptimal recording efficiency. In this work, we present a systematic design framework for conformal planar penetrating MEAs that explicitly links neuroanatomical constraints to key engineering decisions, including probe geometry, shank arrangement, electrode distribution, and implantation strategy. The framework integrates anatomical analysis, surgical considerations, device prototyping, electrophysiological validation, and histological verification within an iterative workflow, enabling progressive refinement from initial concept to final design. We illustrate this approach through representative case studies with an initial emphasis on hippocampal arrays, where highly curved and layered cytoarchitecture presents stringent design challenges, and subsequent extensions to other brain regions and animal models. These examples demonstrate how anatomy-aware, conformal designs can improve access to targeted neural structures and enable multi-region recordings. Overall, this work provides a practical, generalizable methodology for designing conformal planar penetrating MEAs. The proposed framework complements existing high-density and/or flexible probes, offering a unifying perspective for developing anatomically tailored neural recording technologies for basic neuroscience research and future translational applications.
- Top Cited PapersOpen Access
- 14 January 2026
- Published by IOP Publishing in Journal of Neural Engineering
- Vol. 23 (1)
Systematic evaluation of surgical insertion of flexible neural probe arrays into deeper brain targets using length modulation methods
Objective. Penetrating polymer-based microelectrode arrays (pMEAs) offer the potential for long term high-quality electrophysiological recordings of dynamic neural activity. Compared to rigid metal wire and silicon MEAs, improved device-tissue interface stability has been reported. However, accurate surgical placement of long, thin shanks in deeper brain regions is challenging as flexibility is achieved at the expense of axial stiffness. This study systematically evaluates then compares two pMEA placement strategies—dissolvable dip coating and molded brace, both with bare, exposed pMEA tips— to address the need for consistent, reliable, and accurate surgical targeting. These methods were selected based on the criteria of ease of fabrication, surgical feasibility, and mechanical performance. Approach. Sham (mechanical model with no electrodes) and fully functional pMEAs with shanks up to 5.5 mm long were fabricated and then modified using biodegradable polyethylene glycol (PEG) to support implantation. PEG was applied to shanks by motorized dip coating or a mechanical mold. Dissolution time and insertion in agarose gel brain models and rat cortex were evaluated followed by targeting of dip coated pMEAs to the rat hippocampus. Main results. Dip coating at high withdrawal speeds achieved uniform coating on shanks. Both strategies yielded similar critical buckling forces and insertion forces for single shank and arrayed pMEAs. Dip coated pMEAs were successfully placed in hippocampal regions without severe tissue damage as confirmed by histology and recordings obtained. Significance. Dip coating is a simpler method to prepare pMEAs for surgical targeting of deep brain regions compared to the bracing technique, as it does not require both a specialized mold and application process. This work provides a guide for researchers using single or multi-shank pMEAs to an accessible insertion strategy for implanting into deep brain regions in rodents and other small animal models.
- 14 January 2026
- Published by IOP Publishing in Journal of Neural Engineering
- Vol. 23 (1)
Top Cited PapersOpen AccessSystematic evaluation of surgical insertion of flexible neural probe arrays into deeper brain targets using length modulation methods
Objective. Penetrating polymer-based microelectrode arrays (pMEAs) offer the potential for long term high-quality electrophysiological recordings of dynamic neural activity. Compared to rigid metal wire and silicon MEAs, improved device-tissue interface stability has been reported. However, accurate surgical placement of long, thin shanks in deeper brain regions is challenging as flexibility is achieved at the expense of axial stiffness. This study systematically evaluates then compares two pMEA placement strategies—dissolvable dip coating and molded brace, both with bare, exposed pMEA tips— to address the need for consistent, reliable, and accurate surgical targeting. These methods were selected based on the criteria of ease of fabrication, surgical feasibility, and mechanical performance. Approach. Sham (mechanical model with no electrodes) and fully functional pMEAs with shanks up to 5.5 mm long were fabricated and then modified using biodegradable polyethylene glycol (PEG) to support implantation. PEG was applied to shanks by motorized dip coating or a mechanical mold. Dissolution time and insertion in agarose gel brain models and rat cortex were evaluated followed by targeting of dip coated pMEAs to the rat hippocampus. Main results. Dip coating at high withdrawal speeds achieved uniform coating on shanks. Both strategies yielded similar critical buckling forces and insertion forces for single shank and arrayed pMEAs. Dip coated pMEAs were successfully placed in hippocampal regions without severe tissue damage as confirmed by histology and recordings obtained. Significance. Dip coating is a simpler method to prepare pMEAs for surgical targeting of deep brain regions compared to the bracing technique, as it does not require both a specialized mold and application process. This work provides a guide for researchers using single or multi-shank pMEAs to an accessible insertion strategy for implanting into deep brain regions in rodents and other small animal models.