Xiaoping Li
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Xiaoping Li has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Wei Quan
School of Instrumentation and Optoelectronic Engineering, Beihang University 1 , Beijing 100191
3 shared publications - Wenfeng Fan
School of Instrumentation and Optoelectronic Engineering, Beihang University 1 , Beijing 100191
3 shared publications - Hang Gao
Beihang University
1 shared publication - Hongyu Pei
Institute of Large-scale Scientific Facility and Center for Zero Magnetic Field Science and the School of Instrumentation and Optoelectronics Engineering, Beihang University, Beijing, China
1 shared publication - Kai Zhang
School of Instrumentation and Optoelectronic Engineering, Beihang University, Beijing, China
1 shared publication Qi Yuan
Unit 32005 of PLA 4 , Beijing
1 shared publication
Latest Publications
- 16 November 2026
- Published by AIP Publishing in Applied Physics Letters
- Vol. 129 (20)
Suppression of magnetic wall relaxation of 21Ne spins by high-temperature vacuum pretreatment
Wall-induced relaxation limits the lifetime of noble-gas nuclear polarization in atomic spin inertial sensors. We compare K–Rb–21Ne cells fabricated from GE180 glass using the established 240 °C vacuum bake and a 400 °C vacuum pretreatment, with two independently fabricated cells for each condition. Over −4000≤Bz≤+4000 nT, the 400 °C treatment reduces the field-averaged effective relaxation rate by 18.6% and the integrated field-history-dependent relaxation by 88.4%, with consistently low branch separation in the 400 °C cells. HF-treated GE180 cells also show reduced field-history dependence. Atomic force microscopy and x-ray photoelectron spectroscopy show pronounced roughening and a lower Ba 3d/O 1s intensity ratio after HF treatment, whereas the 400 °C specimen shows no comparable changes in these quantities. These results indicate that high-temperature vacuum pretreatment suppresses magnetic wall relaxation without the surface roughening and Ba/O reduction observed after HF etching, consistent with thermal passivation of magnetically active surface states.
- 16 November 2026
- Published by AIP Publishing in Applied Physics Letters
- Vol. 129 (20)
Suppression of magnetic wall relaxation of 21Ne spins by high-temperature vacuum pretreatment
Wall-induced relaxation limits the lifetime of noble-gas nuclear polarization in atomic spin inertial sensors. We compare K–Rb–21Ne cells fabricated from GE180 glass using the established 240 °C vacuum bake and a 400 °C vacuum pretreatment, with two independently fabricated cells for each condition. Over −4000≤Bz≤+4000 nT, the 400 °C treatment reduces the field-averaged effective relaxation rate by 18.6% and the integrated field-history-dependent relaxation by 88.4%, with consistently low branch separation in the 400 °C cells. HF-treated GE180 cells also show reduced field-history dependence. Atomic force microscopy and x-ray photoelectron spectroscopy show pronounced roughening and a lower Ba 3d/O 1s intensity ratio after HF treatment, whereas the 400 °C specimen shows no comparable changes in these quantities. These results indicate that high-temperature vacuum pretreatment suppresses magnetic wall relaxation without the surface roughening and Ba/O reduction observed after HF etching, consistent with thermal passivation of magnetically active surface states.
- 20 April 2026
- Published by AIP Publishing in Applied Physics Letters
- Vol. 128 (16)
Decoupling and suppression of opto-thermal drifts in SERF atomic co-magnetometers via precise null-point characterization
The long-term bias stability of spin-exchange relaxation-free atomic co-magnetometers is significantly constrained by coupled opto-thermal fluctuations. Traditionally, random systemic offsets at the magnetic compensation point lead to inconsistent opto-thermal coupling, compromising the reproducibility of sensor performance. In this work, we propose a method to simultaneously decouple and suppress these primary drifts by precisely characterizing the physical null-point of the atomic ensemble. A combined compensation scheme, joining residual rotation angle alignment and transverse magnetic field adjustment, is implemented to isolate the sensor output from fluctuations in probe laser intensity and vapor cell temperature. Experimental results demonstrate that the sensitivities to temperature drifts and probe power fluctuations are suppressed simultaneously at the identified null-point by factors of 72 and 880, respectively. This approach establishes a stable zero point, which is expected to significantly enhance sensor reproducibility and stability without sacrificing fundamental sensing performance.
- 20 April 2026
- Published by AIP Publishing in Applied Physics Letters
- Vol. 128 (16)
Decoupling and suppression of opto-thermal drifts in SERF atomic co-magnetometers via precise null-point characterization
The long-term bias stability of spin-exchange relaxation-free atomic co-magnetometers is significantly constrained by coupled opto-thermal fluctuations. Traditionally, random systemic offsets at the magnetic compensation point lead to inconsistent opto-thermal coupling, compromising the reproducibility of sensor performance. In this work, we propose a method to simultaneously decouple and suppress these primary drifts by precisely characterizing the physical null-point of the atomic ensemble. A combined compensation scheme, joining residual rotation angle alignment and transverse magnetic field adjustment, is implemented to isolate the sensor output from fluctuations in probe laser intensity and vapor cell temperature. Experimental results demonstrate that the sensitivities to temperature drifts and probe power fluctuations are suppressed simultaneously at the identified null-point by factors of 72 and 880, respectively. This approach establishes a stable zero point, which is expected to significantly enhance sensor reproducibility and stability without sacrificing fundamental sensing performance.
- 20 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 75 (00189456) , 1-10
Shipborne Experimental Demonstration of an Atomic Spin Comagnetometer for Dual-Axis Rotation Sensing
Rotation sensing is essential for both fundamental physics and inertial navigation. The atomic spin comagnetometer is a promising candidate for high-precision gyroscopes, owing to its exceptional sensitivity. A key challenge lies in the coupling between magnetic field and rotation inputs, which degrades rotation measurement precision and affects the bias stability of the gyroscope. This study reports the first shipborne demonstration of a dual-axis comagnetometer for rotation sensing, confirming its viability for marine environments. By applying a rotating magnetic field orthogonal to the pump beam, a four-channel system is constructed to simultaneously sense dual-axis magnetic field and rotation. A linearized input–output model supports real-time, decoupled estimation of both inputs. Sea trials confirm that the comagnetometer can reliably monitor the pitch and yaw angular velocities of the vessel over extended durations. The time-domain outputs show good agreement with those from fiber-optic gyroscopes, demonstrating high accuracy and dynamic tracking performance. This study represents a significant step toward transforming atomic spin comagnetometers into practical, high-precision inertial sensors for real-world marine navigation.
- 20 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 75 (00189456) , 1-10
Shipborne Experimental Demonstration of an Atomic Spin Comagnetometer for Dual-Axis Rotation Sensing
Rotation sensing is essential for both fundamental physics and inertial navigation. The atomic spin comagnetometer is a promising candidate for high-precision gyroscopes, owing to its exceptional sensitivity. A key challenge lies in the coupling between magnetic field and rotation inputs, which degrades rotation measurement precision and affects the bias stability of the gyroscope. This study reports the first shipborne demonstration of a dual-axis comagnetometer for rotation sensing, confirming its viability for marine environments. By applying a rotating magnetic field orthogonal to the pump beam, a four-channel system is constructed to simultaneously sense dual-axis magnetic field and rotation. A linearized input–output model supports real-time, decoupled estimation of both inputs. Sea trials confirm that the comagnetometer can reliably monitor the pitch and yaw angular velocities of the vessel over extended durations. The time-domain outputs show good agreement with those from fiber-optic gyroscopes, demonstrating high accuracy and dynamic tracking performance. This study represents a significant step toward transforming atomic spin comagnetometers into practical, high-precision inertial sensors for real-world marine navigation.