Young Jik Youn
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Young Jik Youn has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
Kyosung Choo
3 shared publications- Yong Hoon Im
Department of Mechanical System Engineering, Sookmyung Women’s University, 100 Cheongpa-ro 47-gil, Yongsan-gu, Seoul 04310, Republic of Korea
3 shared publications Jae Joong Ryu
2 shared publications- Ju Young Lee
Smart Farm Research Center, Korea Institute of Science and Technology (KIST), Gangneung 25451, Republic of Korea
2 shared publications Mukesh Kalel
2 shared publications- Siwon Yoon
Department of Smart Farm, College of Agriculture and Life Sciences, Jeonbuk National University, 567 Baekje-Daero, Deokjin-Gu, Jeonju 54896, Republic of Korea
2 shared publications
Latest Publications
- Open Access
- 5 November 2026
- Published by MDPI AG in Sustainability
- Vol. 18 (21) , 11275
Assessment of Seasonal Cold Storage and Intake Sizing for Seawater District Cooling
Integrating seasonal cold storage into seawater district cooling can extend the use of natural cold resources across seasons and change the annual cooling supply mix by compensating for temperature-dependent limitations of direct seawater cooling. In this study, an 8760 h simulation evaluates hybrid cooling scenarios using a measured annual cooling-load profile from an operating district cooling branch supplying chilled water, totaling approximately 171 GWh. The system prioritizes direct seawater cooling, followed by discharge from a prescribed initial cold-energy inventory and turbo-chiller backup. Under the same intake conditions, approximately 42 GWh of initial storage reduces the chiller’s annual cooling share from 22.9% to 2.2%. For CS_0.198, with approximately 33.8 GWh of initial storage, a +2 °C source-temperature shift advances the 10% storage discharge cutoff from about day 274 to day 196. Increasing the prescribed daily heat-loss coefficient from 0.03% to 0.15% advances it to about day 239. Hourly pumping profiles and annual electricity comparisons show why this reduction in refrigeration duty does not ensure a comparable electricity reduction. For an annual electricity ratio R ≤ 1.5 relative to the constant-temperature benchmark, the selected storage capacity falls from 42.1 to 16.5 GWh as the intake diameter increases from 1.25 to 1.40 m. These results support joint assessment of storage availability, intake pumping and storage capacity in the preliminary design of hybrid seawater district cooling systems.
- 5 November 2026
- Published by MDPI AG in Sustainability
- Vol. 18 (21) , 11275
Open AccessAssessment of Seasonal Cold Storage and Intake Sizing for Seawater District Cooling
Integrating seasonal cold storage into seawater district cooling can extend the use of natural cold resources across seasons and change the annual cooling supply mix by compensating for temperature-dependent limitations of direct seawater cooling. In this study, an 8760 h simulation evaluates hybrid cooling scenarios using a measured annual cooling-load profile from an operating district cooling branch supplying chilled water, totaling approximately 171 GWh. The system prioritizes direct seawater cooling, followed by discharge from a prescribed initial cold-energy inventory and turbo-chiller backup. Under the same intake conditions, approximately 42 GWh of initial storage reduces the chiller’s annual cooling share from 22.9% to 2.2%. For CS_0.198, with approximately 33.8 GWh of initial storage, a +2 °C source-temperature shift advances the 10% storage discharge cutoff from about day 274 to day 196. Increasing the prescribed daily heat-loss coefficient from 0.03% to 0.15% advances it to about day 239. Hourly pumping profiles and annual electricity comparisons show why this reduction in refrigeration duty does not ensure a comparable electricity reduction. For an annual electricity ratio R ≤ 1.5 relative to the constant-temperature benchmark, the selected storage capacity falls from 42.1 to 16.5 GWh as the intake diameter increases from 1.25 to 1.40 m. These results support joint assessment of storage availability, intake pumping and storage capacity in the preliminary design of hybrid seawater district cooling systems.
- Open Access
- 2 November 2026
- Published by MDPI AG in Agriculture
- Vol. 16 (21) , 2398
Local Heat-Flux Responses of a Greenhouse Envelope and CFD-Predicted Airflow Around a Vertical PV Windbreak
External wind can increase greenhouse heat loss by enhancing airflow over the covering surface. This study investigated the local thermal response of a greenhouse envelope and the airflow around an adjacent field-installed, rigid, non-porous vertical photovoltaic (PV) windbreak using winter heat-flux measurements and three-dimensional computational fluid dynamics (CFD). Field measurements showed a strongly position-dependent thermal response: during the selected nighttime intervals on 13 February, mean heat flux was −7.9 W/m2 at the reference location and ranged from −0.6 to −9.9 W/m2 at windbreak-influenced locations. CFD was used as an exploratory tool to identify airflow structures around the greenhouse–windbreak configuration under prescribed conditions. The simulations showed coexisting sheltered flow, recirculation, edge bypass, and upper-level acceleration. Under side inflow, the line-averaged velocity along the windbreak-facing sidewall decreased by 67.5%, while increasing wall height reduced upper-level velocity by approximately 95%. Additional simulations indicated that wall closure mainly limited bypass flow, whereas increased height displaced the upper high-velocity shear layer. These results show that wall continuity and height act as complementary design parameters. The findings identify wall continuity and height as factors to consider when assessing vertical PV structures for combined wind shielding and electricity generation beside greenhouses.
- 2 November 2026
- Published by MDPI AG in Agriculture
- Vol. 16 (21) , 2398
Open AccessLocal Heat-Flux Responses of a Greenhouse Envelope and CFD-Predicted Airflow Around a Vertical PV Windbreak
External wind can increase greenhouse heat loss by enhancing airflow over the covering surface. This study investigated the local thermal response of a greenhouse envelope and the airflow around an adjacent field-installed, rigid, non-porous vertical photovoltaic (PV) windbreak using winter heat-flux measurements and three-dimensional computational fluid dynamics (CFD). Field measurements showed a strongly position-dependent thermal response: during the selected nighttime intervals on 13 February, mean heat flux was −7.9 W/m2 at the reference location and ranged from −0.6 to −9.9 W/m2 at windbreak-influenced locations. CFD was used as an exploratory tool to identify airflow structures around the greenhouse–windbreak configuration under prescribed conditions. The simulations showed coexisting sheltered flow, recirculation, edge bypass, and upper-level acceleration. Under side inflow, the line-averaged velocity along the windbreak-facing sidewall decreased by 67.5%, while increasing wall height reduced upper-level velocity by approximately 95%. Additional simulations indicated that wall closure mainly limited bypass flow, whereas increased height displaced the upper high-velocity shear layer. These results show that wall continuity and height act as complementary design parameters. The findings identify wall continuity and height as factors to consider when assessing vertical PV structures for combined wind shielding and electricity generation beside greenhouses.
- Open Access
- 22 September 2026
- Published by MDPI AG in Sustainability
- Vol. 18 (19) , 9703
Balancing Resource Circularity and Farm Profitability: A Secondary Probabilistic Bioeconomic Assessment of Partial Nutrient Solution Recirculation in a Korean Indoor Strawberry System
Partial nutrient-solution recirculation can improve resource efficiency without establishing net environmental sustainability or private profitability. This secondary bioeconomic assessment used four fixed-layout operational records per setting for 0%, 30%, and 50% recirculation in a Korean two-tier indoor aeroponic strawberry system. Resource indicators were integrated with partial budgeting, 200,000-draw Monte Carlo simulations, downside-risk measures, complementary uncertainty cases, Sobol sensitivity analysis, and capital-recovery and avoided-discharge shadow-value frontiers. Thirty-percent recirculation reduced freshwater make-up by 30.0% and freshwater intensity by 28.3%, while retaining 97.7% of control yield. At the base price and tariff, its incremental margin was −8364 Korean won (KRW), approximately −6.09 United States dollars (USD), per (25/3) m2 block-cycle; parity required 98.54% yield retention. With the observed mean yield difference fixed, the scenario-conditional positive-margin probability was only 2.95%. It was 24.94% under four-record empirical resampling and 55.35% under an exploratory triangular yield envelope, falling to 16.56% when declared labor and energy/consumables burdens were added to that envelope. The triangular result interpolates across sparse, non-independent records and is not a more empirically supported probability estimate. All probabilities assume independent model inputs and retained, incompletely auditable fertilizer-cost allocations. Fifty-percent recirculation remained unfavorable because yield losses outweighed input savings. These findings identify a resource–profitability trade-off, not an environmentally sustainable or optimal recirculation rate; numerical conclusions require independent crop-, facility-, and market-specific evidence.
- 22 September 2026
- Published by MDPI AG in Sustainability
- Vol. 18 (19) , 9703
Open AccessBalancing Resource Circularity and Farm Profitability: A Secondary Probabilistic Bioeconomic Assessment of Partial Nutrient Solution Recirculation in a Korean Indoor Strawberry System
Partial nutrient-solution recirculation can improve resource efficiency without establishing net environmental sustainability or private profitability. This secondary bioeconomic assessment used four fixed-layout operational records per setting for 0%, 30%, and 50% recirculation in a Korean two-tier indoor aeroponic strawberry system. Resource indicators were integrated with partial budgeting, 200,000-draw Monte Carlo simulations, downside-risk measures, complementary uncertainty cases, Sobol sensitivity analysis, and capital-recovery and avoided-discharge shadow-value frontiers. Thirty-percent recirculation reduced freshwater make-up by 30.0% and freshwater intensity by 28.3%, while retaining 97.7% of control yield. At the base price and tariff, its incremental margin was −8364 Korean won (KRW), approximately −6.09 United States dollars (USD), per (25/3) m2 block-cycle; parity required 98.54% yield retention. With the observed mean yield difference fixed, the scenario-conditional positive-margin probability was only 2.95%. It was 24.94% under four-record empirical resampling and 55.35% under an exploratory triangular yield envelope, falling to 16.56% when declared labor and energy/consumables burdens were added to that envelope. The triangular result interpolates across sparse, non-independent records and is not a more empirically supported probability estimate. All probabilities assume independent model inputs and retained, incompletely auditable fertilizer-cost allocations. Fifty-percent recirculation remained unfavorable because yield losses outweighed input savings. These findings identify a resource–profitability trade-off, not an environmentally sustainable or optimal recirculation rate; numerical conclusions require independent crop-, facility-, and market-specific evidence.
- Open Access
- 15 September 2026
- Published by Elsevier in SSRN Electronic Journal
CFD-Informed Machine-Learning Surrogates for Free-Surface Jet Impingement with Al₂O₃/Water, TiO₂/Water, and Al₂O₃–TiO₂/Water Hybrid Nanofluids
Free-surface liquid jet impingement can provide high local cooling rates, but its use with hybrid nanofluids remains poorly documented. This study develops CFD-informed machine-learning surrogates for an axisymmetric free-surface jet impinging on a uniformly heated target. The volume-of-fluid model was validated against water-jet measurements, giving mean deviations of 3.0% for the radial Nusselt-number distribution and 3.3% for the stagnation-point Nusselt number across four Reynolds numbers. The database contains 91 CFD cases covering deionized water, Al₂O₃/water, TiO₂/water, and a 1:1 Al₂O₃–TiO₂/water hybrid at total particle loadings of 1–4 vol.% and Reynolds numbers of approximately 4,234–10,590. Wall temperature, heat transfer coefficient, and local Nusselt number were extracted at r/D=0, 2, 4, and 6 , yielding 364 observations. MLP, SVR, and CNN–LSTM models were evaluated using case-grouped cross-validation. MLP produced the highest R2 values for wall temperature, heat transfer coefficient, and Nusselt number, with values of 0.999, 0.998, and 0.997, respectively. CNN–LSTM ranked second, while SVR showed larger prediction errors. Permutation analysis identified Reynolds number as the dominant input, followed by radial position; composition effects were smaller. Physically constrained response maps within the sampled flow and composition ranges showed that increasing Reynolds number produced the largest thermal improvement, while nanoparticle composition provided a secondary adjustment. The surrogate models therefore provide a rapid screening tool within the investigated parameter range.
- 15 September 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessCFD-Informed Machine-Learning Surrogates for Free-Surface Jet Impingement with Al₂O₃/Water, TiO₂/Water, and Al₂O₃–TiO₂/Water Hybrid Nanofluids
Free-surface liquid jet impingement can provide high local cooling rates, but its use with hybrid nanofluids remains poorly documented. This study develops CFD-informed machine-learning surrogates for an axisymmetric free-surface jet impinging on a uniformly heated target. The volume-of-fluid model was validated against water-jet measurements, giving mean deviations of 3.0% for the radial Nusselt-number distribution and 3.3% for the stagnation-point Nusselt number across four Reynolds numbers. The database contains 91 CFD cases covering deionized water, Al₂O₃/water, TiO₂/water, and a 1:1 Al₂O₃–TiO₂/water hybrid at total particle loadings of 1–4 vol.% and Reynolds numbers of approximately 4,234–10,590. Wall temperature, heat transfer coefficient, and local Nusselt number were extracted at r/D=0, 2, 4, and 6 , yielding 364 observations. MLP, SVR, and CNN–LSTM models were evaluated using case-grouped cross-validation. MLP produced the highest R2 values for wall temperature, heat transfer coefficient, and Nusselt number, with values of 0.999, 0.998, and 0.997, respectively. CNN–LSTM ranked second, while SVR showed larger prediction errors. Permutation analysis identified Reynolds number as the dominant input, followed by radial position; composition effects were smaller. Physically constrained response maps within the sampled flow and composition ranges showed that increasing Reynolds number produced the largest thermal improvement, while nanoparticle composition provided a secondary adjustment. The surrogate models therefore provide a rapid screening tool within the investigated parameter range.
- Open Access
- 24 March 2026
- Published by Elsevier in SSRN Electronic Journal
Numerical and Experimental Investigation of Transient Thermal Cycles in Multi-layer Laser Hot-wire Directed Energy Deposition of H13 Tool Steel
Laser Hot-Wire Directed Energy Deposition (LHW-DED) is a high-efficiency additive manufacturing technique that leverages laser-material interaction for precise metal deposition. However, the high energy density and complex thermal history often induce thermal strains and distortions. This study presents a comprehensive thermal analysis of the LHW-DED process using an H13 iron-chromium alloy deposited on an A36 low-carbon steel substrate. A multi-layer deposition strategy consisting of five layers (13 zigzag tracks per layer) was investigated. To capture the complex thermal gradients, an integrated sensing approach was employed: a FLIR A655SC infrared camera monitored surface temperature profiles, while five K-type thermocouples tracked subsurface heat dissipation. A transient finite element model (FEM) was developed using ANSYS APDL to simulate the moving heat source and material addition. The simulation results were validated against experimental data, showing maximum deviations between 7.9% and 16.7%. The results demonstrate that the proposed thermal model effectively predicts the thermal cycles and heat-affected zone (HAZ) characteristics, providing a critical foundation for optimizing laser parameters and controlling the mechanical integrity of LHW-DED components.
- 24 March 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessNumerical and Experimental Investigation of Transient Thermal Cycles in Multi-layer Laser Hot-wire Directed Energy Deposition of H13 Tool Steel
Laser Hot-Wire Directed Energy Deposition (LHW-DED) is a high-efficiency additive manufacturing technique that leverages laser-material interaction for precise metal deposition. However, the high energy density and complex thermal history often induce thermal strains and distortions. This study presents a comprehensive thermal analysis of the LHW-DED process using an H13 iron-chromium alloy deposited on an A36 low-carbon steel substrate. A multi-layer deposition strategy consisting of five layers (13 zigzag tracks per layer) was investigated. To capture the complex thermal gradients, an integrated sensing approach was employed: a FLIR A655SC infrared camera monitored surface temperature profiles, while five K-type thermocouples tracked subsurface heat dissipation. A transient finite element model (FEM) was developed using ANSYS APDL to simulate the moving heat source and material addition. The simulation results were validated against experimental data, showing maximum deviations between 7.9% and 16.7%. The results demonstrate that the proposed thermal model effectively predicts the thermal cycles and heat-affected zone (HAZ) characteristics, providing a critical foundation for optimizing laser parameters and controlling the mechanical integrity of LHW-DED components.
- Open Access
- 2 February 2026
- Published by Elsevier in SSRN Electronic Journal
Thermal Modeling of Laser Hot-wire Directed Energy Deposition (DED) Additive Manufacturing Process using H13 Steel
Laser Hot Wire Directed Energy Deposition (LHW-DED) is a widely used additive manufacturing technique known for its simplicity and ability to produce high-quality metal components. It uses a focused laser beam to melt feedstock metal wire, which is deposited layer by layer to form complex parts. However, the intense heat involved can introduce thermal strains and distortions, affecting the final product's integrity. This study conducts a detailed thermal analysis of the LHW-DED process using ANSYS APDL. H13 iron-chromium alloy was deposited in five layers (each with 13 zigzag tracks and 2 mm height) on an A36 low-carbon steel substrate. A 25-second dwell time was applied between layers. Argon gas protected the weld from oxidation, and a FLIR A655SC infrared camera recorded the temperature profile during deposition. Five K-type thermocouples were installed on the base plate—four near the heat-affected zone (HAZ) and one at the substrate’s bottom center. Thermal data were collected using National Instruments hardware and analyzed in LabVIEW and MATLAB. Finite element modeling (FEM) in ANSYS APDL was used to simulate and validate the process. The modeled thermal data showed good agreement with the experimental results, with maximum deviations ranging from 7.9% to 16.7%. This transient thermal modeling provides insight into the thermal cycle of LHW-DED, which is critical for understanding the resulting mechanical properties of the printed part.
- 2 February 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessThermal Modeling of Laser Hot-wire Directed Energy Deposition (DED) Additive Manufacturing Process using H13 Steel
Laser Hot Wire Directed Energy Deposition (LHW-DED) is a widely used additive manufacturing technique known for its simplicity and ability to produce high-quality metal components. It uses a focused laser beam to melt feedstock metal wire, which is deposited layer by layer to form complex parts. However, the intense heat involved can introduce thermal strains and distortions, affecting the final product's integrity. This study conducts a detailed thermal analysis of the LHW-DED process using ANSYS APDL. H13 iron-chromium alloy was deposited in five layers (each with 13 zigzag tracks and 2 mm height) on an A36 low-carbon steel substrate. A 25-second dwell time was applied between layers. Argon gas protected the weld from oxidation, and a FLIR A655SC infrared camera recorded the temperature profile during deposition. Five K-type thermocouples were installed on the base plate—four near the heat-affected zone (HAZ) and one at the substrate’s bottom center. Thermal data were collected using National Instruments hardware and analyzed in LabVIEW and MATLAB. Finite element modeling (FEM) in ANSYS APDL was used to simulate and validate the process. The modeled thermal data showed good agreement with the experimental results, with maximum deviations ranging from 7.9% to 16.7%. This transient thermal modeling provides insight into the thermal cycle of LHW-DED, which is critical for understanding the resulting mechanical properties of the printed part.