Anderson Soplin-Infantes
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Anderson Soplin-Infantes has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Aldo Castillo-Chung
School of Industrial Engineering, César Vallejo University (UCV), Av. Víctor Larco 1770, Víctor Larco Herrera District, Trujillo 13008, Peru
2 shared publications - Alex Antenor Benites Aliaga
School of Industrial Engineering, César Vallejo University (UCV), Av. Víctor Larco 1770, Víctor Larco Herrera District, Trujillo 13008, Peru
2 shared publications - Alexander Yushepy Vega-Anticona
School of Industrial Engineering, César Vallejo University (UCV), Av. Víctor Larco 1770, Víctor Larco Herrera District, Trujillo 13008, Peru
2 shared publications - Claudia Torres-Ruiz
School of Materials Engineering, National University of Trujillo (UNT), Av. Juan Pablo II s/n, University City, La Libertad, Trujillo 13008, Peru
2 shared publications - Elmer Tello-De la Cruz
School of Industrial Engineering, César Vallejo University (UCV), Av. Víctor Larco 1770, Víctor Larco Herrera District, Trujillo 13008, Peru
2 shared publications - Marcos Robles-Lora
School of Industrial Engineering, César Vallejo University (UCV), Av. Víctor Larco 1770, Víctor Larco Herrera District, Trujillo 13008, Peru
2 shared publications
Latest Publications
- Open Access
- 29 October 2026
- Published by MDPI AG in Applied Sciences
- Vol. 16 (21) , 10713
Biomechanical Response of MOD Class II Restorations Considering Polymerization Shrinkage and Transient Occlusal Loading: A Finite Element Study
Class II mesio-occluso-distal (MOD) restorations are routinely used to rehabilitate molars with extensive structural loss, where cavity bases are often employed to protect dentin and modulate stress transfer. However, polymer-based restorative materials undergo polymerization shrinkage during curing, generating residual stresses that are subsequently superimposed on functional occlusal loads during mastication. The interaction between these two stress fields is rarely considered explicitly in finite element studies of MOD restorations. This study evaluates the biomechanical influence of cavity base type and the absence of a cavity base in Class II MOD restorations by means of three-dimensional finite element analysis (3D-FEA). A three-dimensional human molar model was reconstructed from cone-beam computed tomography (CBCT) data. A transient occlusal loading cycle from 0 to 0.25 s was simulated, with a maximum load of 600 N applied at 0.15 s. Restorations with cavity bases were modeled using combinations of ceramic and glass–ceramic restorative materials with different base materials, whereas restorations without cavity bases were modeled using reinforced composite resins with different silica contents. Mechanical behavior was assessed through von Mises stress and maximum principal stress. The results show that stress distribution and stress magnitude depend on the interaction among restorative material properties, cavity base configuration, and the overall stiffness of the system. In particular, certain reinforced composite configurations without cavity bases exhibited a more homogeneous stress distribution and a narrower stress range than some multilayer configurations. However, this behavior should not be generalized to all cavity-base-free restorations, as it depends on the specific mechanical properties of the evaluated materials and the structural configuration of the restorative system. These findings highlight the importance of jointly considering polymerization shrinkage and transient occlusal loading in the biomechanical assessment of MOD restorations, and suggest that, under specific conditions, optimization of restorative material properties may be as relevant as the incorporation of intermediate layers.
- 29 October 2026
- Published by MDPI AG in Applied Sciences
- Vol. 16 (21) , 10713
Open AccessBiomechanical Response of MOD Class II Restorations Considering Polymerization Shrinkage and Transient Occlusal Loading: A Finite Element Study
Class II mesio-occluso-distal (MOD) restorations are routinely used to rehabilitate molars with extensive structural loss, where cavity bases are often employed to protect dentin and modulate stress transfer. However, polymer-based restorative materials undergo polymerization shrinkage during curing, generating residual stresses that are subsequently superimposed on functional occlusal loads during mastication. The interaction between these two stress fields is rarely considered explicitly in finite element studies of MOD restorations. This study evaluates the biomechanical influence of cavity base type and the absence of a cavity base in Class II MOD restorations by means of three-dimensional finite element analysis (3D-FEA). A three-dimensional human molar model was reconstructed from cone-beam computed tomography (CBCT) data. A transient occlusal loading cycle from 0 to 0.25 s was simulated, with a maximum load of 600 N applied at 0.15 s. Restorations with cavity bases were modeled using combinations of ceramic and glass–ceramic restorative materials with different base materials, whereas restorations without cavity bases were modeled using reinforced composite resins with different silica contents. Mechanical behavior was assessed through von Mises stress and maximum principal stress. The results show that stress distribution and stress magnitude depend on the interaction among restorative material properties, cavity base configuration, and the overall stiffness of the system. In particular, certain reinforced composite configurations without cavity bases exhibited a more homogeneous stress distribution and a narrower stress range than some multilayer configurations. However, this behavior should not be generalized to all cavity-base-free restorations, as it depends on the specific mechanical properties of the evaluated materials and the structural configuration of the restorative system. These findings highlight the importance of jointly considering polymerization shrinkage and transient occlusal loading in the biomechanical assessment of MOD restorations, and suggest that, under specific conditions, optimization of restorative material properties may be as relevant as the incorporation of intermediate layers.
- Open Access
- 9 February 2026
- Published by MDPI AG in Preprints.org
Biomechanical Response of Class II MOD Restorations Con-Sidering Polymerization Shrinkage and Transient Occlusal Loading: A Finite Element Study
Class II mesio-occluso-distal (MOD) restorations are routinely used to rehabilitate molars with extensive structural loss, where cavitary bases are commonly applied to protect dentine and modulate stress transfer. Nevertheless, polymer-based restorative materials undergo polymerisation shrinkage during curing, generating residual stresses that subsequently superimpose on functional masticatory loads—a coupled effect that is rarely addressed explicitly in finite element analyses of Class II MOD restorations and may increase stress concentrations and mechanical failure risk. This study investigates the biomechanical influence of cavitary base type and the absence of a cavitary base in Class II MOD restorations through three-dimensional finite element analysis. A patient-based three-dimensional human molar model was reconstructed from cone-beam computed tomography (CBCT) data. A transient occlusal loading cycle from 0 to 0.25 s was simulated, reaching a peak load of 600 N. Restorations incorporating cavitary bases were modelled using ceramic and glass–ceramic restorative materials combined with different base materials, while restorations without bases employed composite materials with varying silica content. Mechanical behaviour was evaluated using von Mises stress and maximum principal stress distributions. The results indicate that restorations without cavitary bases exhibit a more uniform stress distribution and reduced stress concentrations compared with restorations incorporating cavitary bases under transient occlusal loading. These findings suggest that, when polymerisation shrinkage and functional loading are considered simultaneously, the absence of a cavitary base may offer biomechanical advantages in stress transfer and structural integrity for Class II MOD restorations.
- 9 February 2026
- Published by MDPI AG in Preprints.org
Open AccessBiomechanical Response of Class II MOD Restorations Con-Sidering Polymerization Shrinkage and Transient Occlusal Loading: A Finite Element Study
Class II mesio-occluso-distal (MOD) restorations are routinely used to rehabilitate molars with extensive structural loss, where cavitary bases are commonly applied to protect dentine and modulate stress transfer. Nevertheless, polymer-based restorative materials undergo polymerisation shrinkage during curing, generating residual stresses that subsequently superimpose on functional masticatory loads—a coupled effect that is rarely addressed explicitly in finite element analyses of Class II MOD restorations and may increase stress concentrations and mechanical failure risk. This study investigates the biomechanical influence of cavitary base type and the absence of a cavitary base in Class II MOD restorations through three-dimensional finite element analysis. A patient-based three-dimensional human molar model was reconstructed from cone-beam computed tomography (CBCT) data. A transient occlusal loading cycle from 0 to 0.25 s was simulated, reaching a peak load of 600 N. Restorations incorporating cavitary bases were modelled using ceramic and glass–ceramic restorative materials combined with different base materials, while restorations without bases employed composite materials with varying silica content. Mechanical behaviour was evaluated using von Mises stress and maximum principal stress distributions. The results indicate that restorations without cavitary bases exhibit a more uniform stress distribution and reduced stress concentrations compared with restorations incorporating cavitary bases under transient occlusal loading. These findings suggest that, when polymerisation shrinkage and functional loading are considered simultaneously, the absence of a cavitary base may offer biomechanical advantages in stress transfer and structural integrity for Class II MOD restorations.