Mohammadreza Ghandhari
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Mohammadreza Ghandhari has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Ali Ahmadi
Student Research Committee, Faculty of Medicine, Mashhad University of Medical Sciences, Mashhad, Iran
2 shared publications - Alireza Eslampoor
Eye Research Center, Mashhad University of Medical Sciences, Mashhad, Iran
2 shared publications - Armin Doostparast
Eye Research Center, Mashhad University of Medical Sciences, Mashhad, Iran
2 shared publications - Farbod Semnani
School of Medicine, Tehran University of Medical Sciences, Tehran, Iran
2 shared publications - Maryam Ghandhari
Student Research Committee, Faculty of Medicine, Mashhad University of Medical Sciences, Mashhad, Iran
2 shared publications Amir Hossein Khosronejad
Student Research Committee, Mazandaran University of Medical Sciences, Sari, Iran
1 shared publication
Latest Publications
- Open Access
- 26 March 2026
- Published by Springer Nature in Scientific Reports
- Vol. 16 (1)
Agreement and potential for arithmetic adjustment of anterior segment measurements across IOLMaster 700, Pentacam HR, and Sirius
We aimed to evaluate the absolute agreement, consistency, and the potential of arithmetic adjustment for measurements across a swept-source optical coherence tomography biometer (IOLMaster 700), a single Scheimpflug-based tomographer (Pentacam HR), and a combined Scheimpflug-Placido disc-based tomographer (Sirius). This cross-sectional study analyzed the corneal keratometry parameters (Sim-K1, Sim-K2, and Sim-Km, corneal astigmatism (CA), and its Jackson power vectors (J0 and J45), central corneal thickness (CCT), anterior chamber depth (ACD), and the horizontal white-to-white distance (WTW) of 111 healthy eyes. The inter-device agreement was assessed using the Bland-Altman limits of agreement (LoA) and two types of intraclass correlation coefficient (ICC) analyses. A mean difference (MD) translating to less than 0.25D in refractive outcomes was considered clinically acceptable. Except for the WTW (ICC(2,1) = 0.52, ICC(3,1) = 0.65), the inter-device agreement was excellent for all parameters (ICC(2,1) and ICC(3,1) > 0.90), with the CA and its power vectors (ICC(2,1) and ICC(3,1): 0.87–0.90) being slightly inferior. WTW values varied substantially across devices, but applying a constant adjustment (MD = 0.36) between Pentacam HR and Sirius improved agreement (ICC(2,1) rising from 0.59 to 0.90), whereas adjustment was not feasible with IOLMaster 700. CCT and ACD may be considered interchangeable across the three, particularly in intraocular lens (IOL) power calculation (the widest LoA were − 0.20 to 0.16 mm for ACD and − 10.99 to 25.42 μm for CCT, respectively). Keratometry values exhibited clinically relevant LoA (the widest LoA for Sim-Km: − 0.77 to 0.80 diopters), limiting their direct interchangeability. Although WTW showed the greatest variability (the widest LoA: − 0.86 to 0.64 mm), the agreement between Pentacam HR and Sirius could be improved through an arithmetic adjustment. This adjustment indicated a systematic error rather than random variability between Pentacam HR and Sirius. These findings highlight the potential of arithmetic adjustment of WTW, an important variable in implantable collamer lens sizing, similar to constant optimization in the IOL power formulas.
- 26 March 2026
- Published by Springer Nature in Scientific Reports
- Vol. 16 (1)
Open AccessAgreement and potential for arithmetic adjustment of anterior segment measurements across IOLMaster 700, Pentacam HR, and Sirius
We aimed to evaluate the absolute agreement, consistency, and the potential of arithmetic adjustment for measurements across a swept-source optical coherence tomography biometer (IOLMaster 700), a single Scheimpflug-based tomographer (Pentacam HR), and a combined Scheimpflug-Placido disc-based tomographer (Sirius). This cross-sectional study analyzed the corneal keratometry parameters (Sim-K1, Sim-K2, and Sim-Km, corneal astigmatism (CA), and its Jackson power vectors (J0 and J45), central corneal thickness (CCT), anterior chamber depth (ACD), and the horizontal white-to-white distance (WTW) of 111 healthy eyes. The inter-device agreement was assessed using the Bland-Altman limits of agreement (LoA) and two types of intraclass correlation coefficient (ICC) analyses. A mean difference (MD) translating to less than 0.25D in refractive outcomes was considered clinically acceptable. Except for the WTW (ICC(2,1) = 0.52, ICC(3,1) = 0.65), the inter-device agreement was excellent for all parameters (ICC(2,1) and ICC(3,1) > 0.90), with the CA and its power vectors (ICC(2,1) and ICC(3,1): 0.87–0.90) being slightly inferior. WTW values varied substantially across devices, but applying a constant adjustment (MD = 0.36) between Pentacam HR and Sirius improved agreement (ICC(2,1) rising from 0.59 to 0.90), whereas adjustment was not feasible with IOLMaster 700. CCT and ACD may be considered interchangeable across the three, particularly in intraocular lens (IOL) power calculation (the widest LoA were − 0.20 to 0.16 mm for ACD and − 10.99 to 25.42 μm for CCT, respectively). Keratometry values exhibited clinically relevant LoA (the widest LoA for Sim-Km: − 0.77 to 0.80 diopters), limiting their direct interchangeability. Although WTW showed the greatest variability (the widest LoA: − 0.86 to 0.64 mm), the agreement between Pentacam HR and Sirius could be improved through an arithmetic adjustment. This adjustment indicated a systematic error rather than random variability between Pentacam HR and Sirius. These findings highlight the potential of arithmetic adjustment of WTW, an important variable in implantable collamer lens sizing, similar to constant optimization in the IOL power formulas.
- Open Access
- 14 February 2026
- Published by Elsevier in Photodiagnosis and Photodynamic Therapy
- Vol. 59, 105397
Agreement of anterior corneal aberrations between a Placido-disk-based wavefront analyzer and a Scheimpflug system in myopic candidates for refractive surgery
- 14 February 2026
- Published by Elsevier in Photodiagnosis and Photodynamic Therapy
- Vol. 59, 105397
Open AccessAgreement of anterior corneal aberrations between a Placido-disk-based wavefront analyzer and a Scheimpflug system in myopic candidates for refractive surgery