LALuong Nhat Anh

Luong Nhat Anh

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Luong Nhat Anh has a total of 23 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Notch-referenced mediolateral verification of tibial tunnel position in anterior cruciate ligament reconstruction: a 3D imaging validation study

    by Vu Tu Nam, Vu Duc Thang, Le Duc Huy, Luu Huu Phuc, Luong Nhat Anh, Le Duc Thinh, Chu Hoang Long, Nguyen Ngoc Huyen, Nguyen Duc Trung, Ta Van Thanh Nam, et al.

  • Open Access

    3D-printed navicular replacement for giant cell tumor: a case report on a feasible indication and surgical outcome

    by Tran Quang Sang Nguyen, Nhat Anh Luong, Duc Huy Le, Sy Quyen Nang Vo, Trung Hieu Pham, Trung Dung Tran

    Introduction and importance: Giant cell tumor of the navicular is extremely rare and difficult to manage due to the complex biomechanics of the midfoot. Conventional curettage carries a high recurrence risk. This report presents a feasible approach using total navicular replacement for a giant cell tumor, offering a solution for achieving both oncologic control and functional reconstruction. Case presentation: A 32-year-old man presented with progressive midfoot pain and a Campanacci grade II giant cell tumor confined to the navicular. Imaging showed near-complete osteolysis with an intact cortex. A patient-specific titanium implant was designed using virtual surgical planning, incorporating porous surfaces and fixed screw trajectories for talocuneiform fusion. En bloc excision of the navicular and implantation of the custom device were performed through a medial approach. Postoperative recovery was uneventful. By 2 years, the patient was pain-free, exhibited a normal gait, and achieved excellent functional scores, with imaging confirming osseointegration and no recurrence. Clinical discussion: While three-dimension (3D print implants are increasingly used in complex foot and ankle reconstructions, their application for primary bone tumors in the midfoot has not been previously reported. This case demonstrates that custom implants can provide stable midfoot restoration when conventional grafting or curettage is insufficient. Advantages include precise anatomical matching and reliable fixation; however, cost and long-term durability remain considerations. Conclusion: Total navicular replacement using a custom 3D-printed implant achieved excellent 2-year oncologic and functional outcomes in this rare giant cell tumor case. This technique represents a viable and innovative reconstructive option for select midfoot tumors.

  • Open Access

    Liquid nitrogen-treated autograft combined with megaprosthesis versus total femoral replacement for large-volume malignant femoral bone tumors: a comparative study

    by Nguyen Tran Quang Sang, Nguyen Duc Trung, Le Duc Huy, Luu Huu Phuc, Vu Duc Thang, Luong Nhat Anh, Le The Hung, Tran Thi Thu Hien, Tran Tuyet Thanh Hai, Duong Quang Vinh, et al.

    Background: Limb-salvage surgery for extensive femoral osteosarcoma presents major reconstructive challenges. Conventional options such as total femoral replacement (TFR) and long-segment biological reconstructions are associated with significant complications. We evaluated the clinical outcomes of a novel hybrid approach combining a liquid nitrogen-treated autograft with a megaprosthesis (LN-MP) and compared them with those of TFR. Materials and methods: This retrospective study included 28 patients (range 8–24 years old) with malignant femoral bone tumors treated between 2020 and 2024. Patients underwent either LN-MP (n = 10) or TFR (n = 18). Perioperative outcomes, functional results (Musculoskeletal Tumor Society score—MSTS), bone union, oncological control, and survival were analyzed. Results: LN-MP demonstrated better functional outcomes (MSTS 27.0 ± 2.1 vs. 24.4 ± 2.2, p = 0.014), shorter operative time, and lower blood loss compared with TFR. Length of stay and follow-up duration were comparable. Continuous disease-free survival was higher in the LN-MP group (90% vs. 44%, p = 0.058), with lower recurrence (10% vs. 28%). Bone union was achieved in 70% of LN-MP cases at a mean of 9 months, with longer graft length associated with delayed union. Conclusions: LN-MP reconstruction may serve as a joint-preserving alternative to total femoral replacement for patients with extensive malignant femoral tumors. In this preliminary series, LN-MP was associated with favorable functional outcomes, satisfactory graft-host bone union, and acceptable oncological results. Given the retrospective design, limited sample size, and short follow-up duration, further studies with larger cohorts and longer follow-up are required to define the role of LN-MP among contemporary limb-salvage reconstructive strategies. Level of evidence: Therapeutic, Level III: retrospective comparative cohort study.

  • Open Access

    Limb-Salvage Reconstruction of the Proximal Humerus Using Patient-Specific 3D-Printed PEEK Implants: A Midterm Clinical Study

    by Tran Duc Thanh, Le Duc Huy, Nguyen Duc Trung, Luong Nhat Anh, Vu Duc Thang, Luu Huu Phuc, Le The Hung, Vo Sy Quyen Nang, Pham Trung Hieu, Nguyen Tran Quang Sang, et al.

    Background: Reconstruction of the proximal humerus after wide tumor resection is technically demanding, and traditional methods such as allograft–prosthetic composites, reverse shoulder arthroplasty, and metal implants are limited by graft unavailability, pediatric size mismatch, their high cost, and metal-related stress shielding. Polyether ether ketone (PEEK), with its modulus closer to cortical bone and radiolucency, offers a promising alternative. Building upon the success in craniomaxillofacial surgery and its favorable physical characteristics, we applied personalized 3D-printed PEEK implants for proximal humerus reconstruction. This study reports the first evidence of applying patient-specific 3D-printed PEEK implants in the proximal humerus. Methods: A retrospective cohort study was conducted on seven patients who underwent wide resection of primary malignant bone tumors of the proximal humerus, followed by reconstruction using patient-specific 3D-printed PEEK implants. Implant design was based on preoperative computed tomography (CT) imaging, incorporating contralateral humeral mirroring and computer-aided design. The implants were fabricated using fused deposition modeling (FDM) with medical-grade PEEK under stringent thermal control (nozzle temperature > 400 °C and heated build chamber), followed by a controlled annealing process to minimize internal stress, optimize polymer crystallinity, and enhance mechanical durability. Outcomes assessed included implant survival, oncologic control, shoulder range of motion, and functional outcomes measured using the Musculoskeletal Tumor Society (MSTS) score. The mean follow-up duration was 56.3 months. Results: All patient-specific PEEK implants were successfully manufactured and implanted with satisfactory geometric accuracy. Mechanical implant survival was 85.7% at final follow-up, with one implant fracture occurring at 28 months. No cases of deep infection, dislocation, loosening, or permanent neurovascular injury were observed. Local soft-tissue recurrence occurred in two patients (28.6%), without distant metastasis or tumor-related mortality. The limb-salvage rate was 100%. At final follow-up, the mean MSTS score was 23.0 ± 1.6. Shoulder motion was limited but comparable to outcomes reported for conventional anatomic megaprosthetic reconstructions. Conclusions: Patient-specific 3D-printed PEEK implants provide a feasible and oncologically safe option for proximal humerus reconstruction after tumor resection, with acceptable midterm implant survival and functional outcomes. The favorable elastic modulus and radiolucency of PEEK offer distinct biomechanical and imaging advantages over metallic implants. Further design optimization and larger prospective studies are warranted to enhance mechanical durability and functional restoration.