Le Duc Huy
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Le Duc Huy has a total of 42 co-authors. Here are the top co-authors by number of shared publications:
- Dung Tran Trung
Sarcoma Center, Vinmec Times City, Vinmec International Hospital, Hanoi, Vietnam
5 shared publications - Luong Nhat Anh
Sarcoma Center, Vinmec Times City, Vinmec International Hospital, Hanoi, Vietnam
4 shared publications - Nguyen Duc Trung
Sarcoma Center, Vinmec Times City, Vinmec International Hospital, Hanoi, Vietnam
4 shared publications - Luu Huu Phuc
Sarcoma Center, Vinmec Times City, Vinmec International Hospital, Hanoi, Vietnam
3 shared publications - Nang Vo Sy Quyen
Department of Orthopaedic Surgery, College of Health Sciences, VinUniversity, Hanoi, Viet Nam
3 shared publications - Pham Trung Hieu
Orthopedics & Sports Medicine Center, Vinmec Times City, Vinmec International Hospital, Hanoi, Vietnam
3 shared publications
Latest Publications
- Open Access
- 13 October 2026
- Published by Springer Nature in Archives of orthopaedic and trauma surgery
- Vol. 146 (1) , 368
Notch-referenced mediolateral verification of tibial tunnel position in anterior cruciate ligament reconstruction: a 3D imaging validation study
- 13 October 2026
- Published by Springer Nature in Archives of orthopaedic and trauma surgery
- Vol. 146 (1) , 368
Open AccessNotch-referenced mediolateral verification of tibial tunnel position in anterior cruciate ligament reconstruction: a 3D imaging validation study
- Open Access
- 16 September 2026
- Published by Wolters Kluwer Health in International Journal of Surgery Case Reports
Revision total hip arthroplasty for osteolysis and metallosis 17 years post-THA: a case report and literature review
Introduction and importance: Pseudotumor formation and adverse reactions to metal debris are typically associated with metal-on-metal (MoM) total hip arthroplasty (THA) but are uncommon in metal-on-polyethylene (MoP) constructs. Catastrophic polyethylene liner wear leading to metallosis is rare and may present late. This case highlights severe wear-related failure occurring 17 years after primary THA. Case presentation: A 70-year-old man presented with progressive left hip pain and impaired mobility. Physical examination showed markedly restricted motion, and the Harris Hip Score was 35; he required crutches for ambulation. Radiographs revealed extensive osteolysis around the acetabular component and proximal femur, extending to the pubic ramus and femoral calcar. Cross-sectional imaging demonstrated a large pseudotumor with metal infiltration. Biopsy confirmed metallosis. Intraoperatively, complete polyethylene liner wear-through was identified, with direct MoM articulation between the femoral head and acetabular shell. The patient underwent revision THA using ceramic-on-ceramic bearing surfaces and cement augmentation. Clinical discussion: Although pseudotumor and metallosis are strongly linked to MoM bearings, advanced polyethylene wear can produce similar adverse local tissue reactions. Because symptoms may arise only after substantial structural compromise, late presentations remain a clinical risk. Long-term follow-up – particularly beyond 10–15 years – is crucial for detecting progressive wear, osteolysis, and soft-tissue changes before severe destruction occurs. This case illustrates the potential for catastrophic liner failure even in non-MoM constructs. Conclusion: Severe polyethylene wear in MoP THA can lead to metallosis and pseudotumor formation many years after implantation. Vigilant long-term surveillance is essential to ensure early recognition and timely revision to prevent extensive osteolysis and tissue damage.
- 16 September 2026
- Published by Wolters Kluwer Health in International Journal of Surgery Case Reports
Open AccessRevision total hip arthroplasty for osteolysis and metallosis 17 years post-THA: a case report and literature review
Introduction and importance: Pseudotumor formation and adverse reactions to metal debris are typically associated with metal-on-metal (MoM) total hip arthroplasty (THA) but are uncommon in metal-on-polyethylene (MoP) constructs. Catastrophic polyethylene liner wear leading to metallosis is rare and may present late. This case highlights severe wear-related failure occurring 17 years after primary THA. Case presentation: A 70-year-old man presented with progressive left hip pain and impaired mobility. Physical examination showed markedly restricted motion, and the Harris Hip Score was 35; he required crutches for ambulation. Radiographs revealed extensive osteolysis around the acetabular component and proximal femur, extending to the pubic ramus and femoral calcar. Cross-sectional imaging demonstrated a large pseudotumor with metal infiltration. Biopsy confirmed metallosis. Intraoperatively, complete polyethylene liner wear-through was identified, with direct MoM articulation between the femoral head and acetabular shell. The patient underwent revision THA using ceramic-on-ceramic bearing surfaces and cement augmentation. Clinical discussion: Although pseudotumor and metallosis are strongly linked to MoM bearings, advanced polyethylene wear can produce similar adverse local tissue reactions. Because symptoms may arise only after substantial structural compromise, late presentations remain a clinical risk. Long-term follow-up – particularly beyond 10–15 years – is crucial for detecting progressive wear, osteolysis, and soft-tissue changes before severe destruction occurs. This case illustrates the potential for catastrophic liner failure even in non-MoM constructs. Conclusion: Severe polyethylene wear in MoP THA can lead to metallosis and pseudotumor formation many years after implantation. Vigilant long-term surveillance is essential to ensure early recognition and timely revision to prevent extensive osteolysis and tissue damage.
- Open Access
- 21 August 2026
- Published by Wolters Kluwer Health in International Journal of Surgery Case Reports
- Vol. 138 (9) , 3297-3302
3D-printed navicular replacement for giant cell tumor: a case report on a feasible indication and surgical outcome
Introduction and importance: Giant cell tumor of the navicular is extremely rare and difficult to manage due to the complex biomechanics of the midfoot. Conventional curettage carries a high recurrence risk. This report presents a feasible approach using total navicular replacement for a giant cell tumor, offering a solution for achieving both oncologic control and functional reconstruction. Case presentation: A 32-year-old man presented with progressive midfoot pain and a Campanacci grade II giant cell tumor confined to the navicular. Imaging showed near-complete osteolysis with an intact cortex. A patient-specific titanium implant was designed using virtual surgical planning, incorporating porous surfaces and fixed screw trajectories for talocuneiform fusion. En bloc excision of the navicular and implantation of the custom device were performed through a medial approach. Postoperative recovery was uneventful. By 2 years, the patient was pain-free, exhibited a normal gait, and achieved excellent functional scores, with imaging confirming osseointegration and no recurrence. Clinical discussion: While three-dimension (3D print implants are increasingly used in complex foot and ankle reconstructions, their application for primary bone tumors in the midfoot has not been previously reported. This case demonstrates that custom implants can provide stable midfoot restoration when conventional grafting or curettage is insufficient. Advantages include precise anatomical matching and reliable fixation; however, cost and long-term durability remain considerations. Conclusion: Total navicular replacement using a custom 3D-printed implant achieved excellent 2-year oncologic and functional outcomes in this rare giant cell tumor case. This technique represents a viable and innovative reconstructive option for select midfoot tumors.
- 21 August 2026
- Published by Wolters Kluwer Health in International Journal of Surgery Case Reports
- Vol. 138 (9) , 3297-3302
Open Access3D-printed navicular replacement for giant cell tumor: a case report on a feasible indication and surgical outcome
Introduction and importance: Giant cell tumor of the navicular is extremely rare and difficult to manage due to the complex biomechanics of the midfoot. Conventional curettage carries a high recurrence risk. This report presents a feasible approach using total navicular replacement for a giant cell tumor, offering a solution for achieving both oncologic control and functional reconstruction. Case presentation: A 32-year-old man presented with progressive midfoot pain and a Campanacci grade II giant cell tumor confined to the navicular. Imaging showed near-complete osteolysis with an intact cortex. A patient-specific titanium implant was designed using virtual surgical planning, incorporating porous surfaces and fixed screw trajectories for talocuneiform fusion. En bloc excision of the navicular and implantation of the custom device were performed through a medial approach. Postoperative recovery was uneventful. By 2 years, the patient was pain-free, exhibited a normal gait, and achieved excellent functional scores, with imaging confirming osseointegration and no recurrence. Clinical discussion: While three-dimension (3D print implants are increasingly used in complex foot and ankle reconstructions, their application for primary bone tumors in the midfoot has not been previously reported. This case demonstrates that custom implants can provide stable midfoot restoration when conventional grafting or curettage is insufficient. Advantages include precise anatomical matching and reliable fixation; however, cost and long-term durability remain considerations. Conclusion: Total navicular replacement using a custom 3D-printed implant achieved excellent 2-year oncologic and functional outcomes in this rare giant cell tumor case. This technique represents a viable and innovative reconstructive option for select midfoot tumors.
- Open Access
- 12 August 2026
- Published by Springer Nature in Archives of orthopaedic and trauma surgery
- Vol. 146 (1) , 297
Liquid nitrogen-treated autograft combined with megaprosthesis versus total femoral replacement for large-volume malignant femoral bone tumors: a comparative study
Background: Limb-salvage surgery for extensive femoral osteosarcoma presents major reconstructive challenges. Conventional options such as total femoral replacement (TFR) and long-segment biological reconstructions are associated with significant complications. We evaluated the clinical outcomes of a novel hybrid approach combining a liquid nitrogen-treated autograft with a megaprosthesis (LN-MP) and compared them with those of TFR. Materials and methods: This retrospective study included 28 patients (range 8–24 years old) with malignant femoral bone tumors treated between 2020 and 2024. Patients underwent either LN-MP (n = 10) or TFR (n = 18). Perioperative outcomes, functional results (Musculoskeletal Tumor Society score—MSTS), bone union, oncological control, and survival were analyzed. Results: LN-MP demonstrated better functional outcomes (MSTS 27.0 ± 2.1 vs. 24.4 ± 2.2, p = 0.014), shorter operative time, and lower blood loss compared with TFR. Length of stay and follow-up duration were comparable. Continuous disease-free survival was higher in the LN-MP group (90% vs. 44%, p = 0.058), with lower recurrence (10% vs. 28%). Bone union was achieved in 70% of LN-MP cases at a mean of 9 months, with longer graft length associated with delayed union. Conclusions: LN-MP reconstruction may serve as a joint-preserving alternative to total femoral replacement for patients with extensive malignant femoral tumors. In this preliminary series, LN-MP was associated with favorable functional outcomes, satisfactory graft-host bone union, and acceptable oncological results. Given the retrospective design, limited sample size, and short follow-up duration, further studies with larger cohorts and longer follow-up are required to define the role of LN-MP among contemporary limb-salvage reconstructive strategies. Level of evidence: Therapeutic, Level III: retrospective comparative cohort study.
- 12 August 2026
- Published by Springer Nature in Archives of orthopaedic and trauma surgery
- Vol. 146 (1) , 297
Open AccessLiquid nitrogen-treated autograft combined with megaprosthesis versus total femoral replacement for large-volume malignant femoral bone tumors: a comparative study
Background: Limb-salvage surgery for extensive femoral osteosarcoma presents major reconstructive challenges. Conventional options such as total femoral replacement (TFR) and long-segment biological reconstructions are associated with significant complications. We evaluated the clinical outcomes of a novel hybrid approach combining a liquid nitrogen-treated autograft with a megaprosthesis (LN-MP) and compared them with those of TFR. Materials and methods: This retrospective study included 28 patients (range 8–24 years old) with malignant femoral bone tumors treated between 2020 and 2024. Patients underwent either LN-MP (n = 10) or TFR (n = 18). Perioperative outcomes, functional results (Musculoskeletal Tumor Society score—MSTS), bone union, oncological control, and survival were analyzed. Results: LN-MP demonstrated better functional outcomes (MSTS 27.0 ± 2.1 vs. 24.4 ± 2.2, p = 0.014), shorter operative time, and lower blood loss compared with TFR. Length of stay and follow-up duration were comparable. Continuous disease-free survival was higher in the LN-MP group (90% vs. 44%, p = 0.058), with lower recurrence (10% vs. 28%). Bone union was achieved in 70% of LN-MP cases at a mean of 9 months, with longer graft length associated with delayed union. Conclusions: LN-MP reconstruction may serve as a joint-preserving alternative to total femoral replacement for patients with extensive malignant femoral tumors. In this preliminary series, LN-MP was associated with favorable functional outcomes, satisfactory graft-host bone union, and acceptable oncological results. Given the retrospective design, limited sample size, and short follow-up duration, further studies with larger cohorts and longer follow-up are required to define the role of LN-MP among contemporary limb-salvage reconstructive strategies. Level of evidence: Therapeutic, Level III: retrospective comparative cohort study.
- 24 July 2026
- Published by Open Medical Publishing in Orthopedic Reviews
- Vol. 18
Limb-Predominant Familial Multiple Lipomatosis: The Role of En Bloc Excision and Systematic Pedigree in Modern Surgical Practice – A Case Report
Introduction: Familial multiple lipomatosis (FML) is a rare hereditary disorder characterized by multiple encapsulated subcutaneous lipomas, typically sparing the head and neck. Although benign, these lesions often necessitate intervention due to cosmetic deformity, discomfort, or functional impairment. Case Presentation: A 36-year-old male presented with a 6-month history of multiple, gradually enlarging, mildly painful subcutaneous masses in both arms and thighs. Physical examination revealed 16 soft, mobile nodules; the largest measured 6 × 7 cm in the left thigh. Preoperative ultrasonography of an arm lesion suggested a heterogeneous fluid collection without a discrete solid mass. Management and Outcomes: All lesions were excised en bloc under general anesthesia using tumescent infiltration and incisions along Langer’s lines. Histopathology confirmed mature adipocytes with thin fibrous septa and branching capillaries, without atypia, consistent with lipomas. Recovery was uneventful. Subsequent pedigree analysis identified affected maternal relatives, confirming FML. Conclusion: This case underscores the necessity of systematic family history and oncologically safe excision for symptomatic FML.
- 24 July 2026
- Published by Open Medical Publishing in Orthopedic Reviews
- Vol. 18
Limb-Predominant Familial Multiple Lipomatosis: The Role of En Bloc Excision and Systematic Pedigree in Modern Surgical Practice – A Case Report
Introduction: Familial multiple lipomatosis (FML) is a rare hereditary disorder characterized by multiple encapsulated subcutaneous lipomas, typically sparing the head and neck. Although benign, these lesions often necessitate intervention due to cosmetic deformity, discomfort, or functional impairment. Case Presentation: A 36-year-old male presented with a 6-month history of multiple, gradually enlarging, mildly painful subcutaneous masses in both arms and thighs. Physical examination revealed 16 soft, mobile nodules; the largest measured 6 × 7 cm in the left thigh. Preoperative ultrasonography of an arm lesion suggested a heterogeneous fluid collection without a discrete solid mass. Management and Outcomes: All lesions were excised en bloc under general anesthesia using tumescent infiltration and incisions along Langer’s lines. Histopathology confirmed mature adipocytes with thin fibrous septa and branching capillaries, without atypia, consistent with lipomas. Recovery was uneventful. Subsequent pedigree analysis identified affected maternal relatives, confirming FML. Conclusion: This case underscores the necessity of systematic family history and oncologically safe excision for symptomatic FML.
- Open Access
- 1 April 2026
- Published by SAGE Publications in Foot & Ankle Orthopaedics
- Vol. 11 (2)
Adolescent Flexible Flatfoot: A Cross-Sectional Analysis of Radiographs, Arch Index, and Plantar Pressure
Background: Pediatric flatfoot is a prevalent condition, and its assessment often involves clinical, radiographic, and functional measures. Although symptoms remain central to treatment decisions, radiographic angles, plantar-pressure metrics, and the Arch Index offer quantitative descriptors. Studying their interrelationships is useful to understand how structure and function are linked. This study examined plantar pressure distribution and the relationships among radiographic parameters, Arch Index, and dynamic loading. Methods: This retrospective single-center study included 27 children (51 feet) aged 10-18 years who were diagnosed with flexible flatfoot. Dynamic plantar pressure and contact area were measured, with foot segmentation guided by a foot axis defined as a straight line drawn from the midpoint between the second and third toes to the point of highest pressure in the heel region. Weight-bearing radiographs were used to assess the Meary angle and calcaneal pitch. The Arch Index was derived from dynamic footprints. Correlations among plantar pressure ratios, Arch Index, and radiographic angles were analyzed. Results: Radiographic assessment confirmed flatfoot deformity (mean Meary angle, 20.07°; calcaneal pitch, 11.75°) and an elevated Arch Index. Forefoot loading showed significant anteromedial predominance (medial pressure ≈1.5 × lateral, P < .01), whereas no mediolateral differences were observed in the midfoot or hindfoot. Correlation analysis revealed no significant relationships among the plantar pressure ratio, Arch Index, and radiographic measurements. Conclusion: In adolescent flexible flatfoot, dynamic loading demonstrates anteromedial forefoot predominance. Radiographic angles and dynamic (pedobarography) assessments capture complementary, non-interchangeable aspects of flatfoot. Dynamic analysis may provide additional insight into region-specific loading patterns. Further studies are needed to define its role in clinical decision making. Level of Evidence: Level III, diagnostic, retrospective.
- 1 April 2026
- Published by SAGE Publications in Foot & Ankle Orthopaedics
- Vol. 11 (2)
Open AccessAdolescent Flexible Flatfoot: A Cross-Sectional Analysis of Radiographs, Arch Index, and Plantar Pressure
Background: Pediatric flatfoot is a prevalent condition, and its assessment often involves clinical, radiographic, and functional measures. Although symptoms remain central to treatment decisions, radiographic angles, plantar-pressure metrics, and the Arch Index offer quantitative descriptors. Studying their interrelationships is useful to understand how structure and function are linked. This study examined plantar pressure distribution and the relationships among radiographic parameters, Arch Index, and dynamic loading. Methods: This retrospective single-center study included 27 children (51 feet) aged 10-18 years who were diagnosed with flexible flatfoot. Dynamic plantar pressure and contact area were measured, with foot segmentation guided by a foot axis defined as a straight line drawn from the midpoint between the second and third toes to the point of highest pressure in the heel region. Weight-bearing radiographs were used to assess the Meary angle and calcaneal pitch. The Arch Index was derived from dynamic footprints. Correlations among plantar pressure ratios, Arch Index, and radiographic angles were analyzed. Results: Radiographic assessment confirmed flatfoot deformity (mean Meary angle, 20.07°; calcaneal pitch, 11.75°) and an elevated Arch Index. Forefoot loading showed significant anteromedial predominance (medial pressure ≈1.5 × lateral, P < .01), whereas no mediolateral differences were observed in the midfoot or hindfoot. Correlation analysis revealed no significant relationships among the plantar pressure ratio, Arch Index, and radiographic measurements. Conclusion: In adolescent flexible flatfoot, dynamic loading demonstrates anteromedial forefoot predominance. Radiographic angles and dynamic (pedobarography) assessments capture complementary, non-interchangeable aspects of flatfoot. Dynamic analysis may provide additional insight into region-specific loading patterns. Further studies are needed to define its role in clinical decision making. Level of Evidence: Level III, diagnostic, retrospective.
- Open Access
- 22 February 2026
- Published by MDPI AG in Bioengineering
- Vol. 13 (2) , 253
Limb-Salvage Reconstruction of the Proximal Humerus Using Patient-Specific 3D-Printed PEEK Implants: A Midterm Clinical Study
Background: Reconstruction of the proximal humerus after wide tumor resection is technically demanding, and traditional methods such as allograft–prosthetic composites, reverse shoulder arthroplasty, and metal implants are limited by graft unavailability, pediatric size mismatch, their high cost, and metal-related stress shielding. Polyether ether ketone (PEEK), with its modulus closer to cortical bone and radiolucency, offers a promising alternative. Building upon the success in craniomaxillofacial surgery and its favorable physical characteristics, we applied personalized 3D-printed PEEK implants for proximal humerus reconstruction. This study reports the first evidence of applying patient-specific 3D-printed PEEK implants in the proximal humerus. Methods: A retrospective cohort study was conducted on seven patients who underwent wide resection of primary malignant bone tumors of the proximal humerus, followed by reconstruction using patient-specific 3D-printed PEEK implants. Implant design was based on preoperative computed tomography (CT) imaging, incorporating contralateral humeral mirroring and computer-aided design. The implants were fabricated using fused deposition modeling (FDM) with medical-grade PEEK under stringent thermal control (nozzle temperature > 400 °C and heated build chamber), followed by a controlled annealing process to minimize internal stress, optimize polymer crystallinity, and enhance mechanical durability. Outcomes assessed included implant survival, oncologic control, shoulder range of motion, and functional outcomes measured using the Musculoskeletal Tumor Society (MSTS) score. The mean follow-up duration was 56.3 months. Results: All patient-specific PEEK implants were successfully manufactured and implanted with satisfactory geometric accuracy. Mechanical implant survival was 85.7% at final follow-up, with one implant fracture occurring at 28 months. No cases of deep infection, dislocation, loosening, or permanent neurovascular injury were observed. Local soft-tissue recurrence occurred in two patients (28.6%), without distant metastasis or tumor-related mortality. The limb-salvage rate was 100%. At final follow-up, the mean MSTS score was 23.0 ± 1.6. Shoulder motion was limited but comparable to outcomes reported for conventional anatomic megaprosthetic reconstructions. Conclusions: Patient-specific 3D-printed PEEK implants provide a feasible and oncologically safe option for proximal humerus reconstruction after tumor resection, with acceptable midterm implant survival and functional outcomes. The favorable elastic modulus and radiolucency of PEEK offer distinct biomechanical and imaging advantages over metallic implants. Further design optimization and larger prospective studies are warranted to enhance mechanical durability and functional restoration.
- 22 February 2026
- Published by MDPI AG in Bioengineering
- Vol. 13 (2) , 253
Open AccessLimb-Salvage Reconstruction of the Proximal Humerus Using Patient-Specific 3D-Printed PEEK Implants: A Midterm Clinical Study
Background: Reconstruction of the proximal humerus after wide tumor resection is technically demanding, and traditional methods such as allograft–prosthetic composites, reverse shoulder arthroplasty, and metal implants are limited by graft unavailability, pediatric size mismatch, their high cost, and metal-related stress shielding. Polyether ether ketone (PEEK), with its modulus closer to cortical bone and radiolucency, offers a promising alternative. Building upon the success in craniomaxillofacial surgery and its favorable physical characteristics, we applied personalized 3D-printed PEEK implants for proximal humerus reconstruction. This study reports the first evidence of applying patient-specific 3D-printed PEEK implants in the proximal humerus. Methods: A retrospective cohort study was conducted on seven patients who underwent wide resection of primary malignant bone tumors of the proximal humerus, followed by reconstruction using patient-specific 3D-printed PEEK implants. Implant design was based on preoperative computed tomography (CT) imaging, incorporating contralateral humeral mirroring and computer-aided design. The implants were fabricated using fused deposition modeling (FDM) with medical-grade PEEK under stringent thermal control (nozzle temperature > 400 °C and heated build chamber), followed by a controlled annealing process to minimize internal stress, optimize polymer crystallinity, and enhance mechanical durability. Outcomes assessed included implant survival, oncologic control, shoulder range of motion, and functional outcomes measured using the Musculoskeletal Tumor Society (MSTS) score. The mean follow-up duration was 56.3 months. Results: All patient-specific PEEK implants were successfully manufactured and implanted with satisfactory geometric accuracy. Mechanical implant survival was 85.7% at final follow-up, with one implant fracture occurring at 28 months. No cases of deep infection, dislocation, loosening, or permanent neurovascular injury were observed. Local soft-tissue recurrence occurred in two patients (28.6%), without distant metastasis or tumor-related mortality. The limb-salvage rate was 100%. At final follow-up, the mean MSTS score was 23.0 ± 1.6. Shoulder motion was limited but comparable to outcomes reported for conventional anatomic megaprosthetic reconstructions. Conclusions: Patient-specific 3D-printed PEEK implants provide a feasible and oncologically safe option for proximal humerus reconstruction after tumor resection, with acceptable midterm implant survival and functional outcomes. The favorable elastic modulus and radiolucency of PEEK offer distinct biomechanical and imaging advantages over metallic implants. Further design optimization and larger prospective studies are warranted to enhance mechanical durability and functional restoration.