NSNor Adrian Nor Salim

Nor Adrian Nor Salim

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Nor Adrian Nor Salim has a total of 9 co-authors. Here are the top co-authors by number of shared publications:

  • Ahmad Fu’ad Idris

    Industrial and Indoor Environment Research Group, Fakulti Kejuruteraan Mekanikal dan Pembuatan, Universiti Tun Hussein Onn Malaysia, 86400 Parit Raja, Johor, Malaysia

    1 shared publication
  • Ahmad Mubarak Tajul Arifin

    Mechanical Failure Prevention and Reliability Research Center, Faculty of Mechanical and Manufacturing Engineering, Universiti Tun Hussein Onn Malaysia, 86400 Parit Raja, Batu Pahat , Johor, Malaysia

    1 shared publication
  • Azian Hariri

    Faculty of Mechanical and Manufacturing Engineering, Universiti Tun Hussein Onn Malaysia, 86400 Parit Raja, Johor, Malaysia

    1 shared publication
  • Azizi Afandi

    Industrial and Indoor Environment Research Group, Fakulti Kejuruteraan Mekanikal dan Pembuatan, Universiti Tun Hussein Onn Malaysia, 86400 Parit Raja, Johor, Malaysia

    1 shared publication
  • Hanis Zakaria

    Universiti Tun Hussein Onn Malaysia

    1 shared publication
  • Ishkrizat Taib

    Faculty of Mechanical and Manufacturing Engineering, Universiti Tun Hussein Onn Malaysia (UTHM), Batu Pahat, Malaysia

    1 shared publication

Latest Publications

  • Open Access

    Experimental Investigation on Filtration and Cooling Effect of Kitchen Hood Ventilation System from Water-Mist Recirculation Spray: Water-Mist Spray Cycle

    by Nor Adrian Nor Salim, Norzelawati Asmuin, Azian Hariri, M. Farid Sies, Hanis Zakaria, Ahmad Fu’ad Idris, Azizi Afandi, M. Asrul Bosiran, Ishkrizat Taib, Ahmad Mubarak Tajul Arifin

    A Water-mist spray system in several heavy-duty kitchen hood canopies is installed to efficiently control the high heat loads and grease emissions produced from the cooking process and for safety purposes. The main purpose of this study is to reduce water consumption by introducing the water-mist recirculation system to replace the current method water-mist system since it is working as water loss. A standard ASTM 2519 and UL 1046 full-scaled experiment is developed in the laboratory. An existing Halton Europe/Asian water-mist operating system is adopted in this study. Twelve (12) cycles (at 24 hours of water-mist activation) have been studied to determine the maximum water-mist activation cycle. The data are collected at two (2) hours water-mist activation at every water-mist recirculation cycle. The water-mist spray fluids viscosity is 0.7 cP from fresh water until the 4th cycle (8 hours water-mist spray) and increase 14.29% (0.8 cP) at the 5th cycle to the 12th cycle. On average, the difference in gas emissions percentage for CO concentration between fresh water until the 4th cycle is 10.81 – 18.92% while the CO2 concentration is 12.33 – 18.22%. On average, the difference in cooling effects percentage for ducting temperature between fresh water until the 4th cycle is 5.55% while the hood temperature is 2.33%. From the study, the water-mist recirculation system could save up to 611,667 litres per year and 466,798.5 litres per year water for all U.S, European, and Asian kitchen hood designs per hood length. By adopting the new water-mist recirculation system to the current water-mist kitchen hood, the water operational cost for water successfully reduced to RM 4,889.63 per year and RM 6,977.86 per year for U.S design and European or Asian design per hood length respectively. The water-mist recirculation system has great potential to improve the current water-mist system for the commercial kitchen hood.