Iman Amani Tehrani
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Iman Amani Tehrani has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Babak Shadgan
Department of Orthopaedics, University of British Columbia, Vancouver, Canada
2 shared publications - Ali Bashashati
University of British Columbia
1 shared publication - Amir Parham Pirhadi Rad
Department of Pathology and Laboratory Medicine, The University of British Columbia, Vancouver, Canada
1 shared publication - Jocelyn Begin
Implantable Biosensing Laboratory, International Collaboration on Repair Discoveries (ICORD), Vancouver, BC V5Z 1M9, Canada
1 shared publication - Kiana Jahanshahi
Implantable Biosensing Laboratory, International Collaboration on Repair Discoveries (ICORD), Vancouver, BC V5Z 1M9, Canada
1 shared publication - Mehdi Nourizadeh
Implantable Biosensing Laboratory, International Collaboration on Repair Discoveries (ICORD), Vancouver, BC V5Z 1M9, Canada
1 shared publication
Latest Publications
- Open Access
Evaluating Continuous SpO2 as a Lactate-Threshold Marker: Implications for Wearable Sports-Monitoring Systems
Continuous peripheral oxygen saturation (SpO2) monitoring can describe systemic oxygenation during exercise, but its value for identifying blood lactate threshold (LT) depends on the timing of recognizable signal changes. Two independent cohorts of 18 healthy adults completed the same incremental cycling protocol with forehead or fingertip pulse oximetry. We characterized SpO2 at key landmarks and throughout exercise and evaluated three changes: a decrease exceeding individual early-exercise variation, a rapid recent decline, and a sustained transition to a steeper decline. All detectors used only measurements available at each update. Event times were compared with Dmax and modified Dmax LT, distinguishing the sustained transition’s estimated breakpoint from its later detection. The first decrease typically preceded LT by 13–16 min. Rapid recent declines also showed substantial timing errors; requiring steeper declines reduced detection coverage. Sustained transitions were detected in 14/18 forehead and 13/18 fingertip recordings. Detection times were closer to LT than breakpoints, but median absolute detection errors remained 3.09–4.25 min across cohorts and LT definitions. Only 4–5 of 18 recordings per cohort had detection times within ±2 min of LT. Timing accuracy remained limited under alternative processing and detection settings. In a separate trajectory comparison, the fingertip cohort showed a larger SpO2 decline. Separate adjustments for exercise frequency and attained workload per kilogram of body mass reduced the estimated cohort difference, but the design could not isolate anatomical-site or sensor-configuration effects. Continuous SpO2 therefore characterized exercise-related oxygenation changes, but these three features had limited accuracy as stand-alone LT markers in healthy adults under this cycling protocol.
Open AccessEvaluating Continuous SpO2 as a Lactate-Threshold Marker: Implications for Wearable Sports-Monitoring Systems
Continuous peripheral oxygen saturation (SpO2) monitoring can describe systemic oxygenation during exercise, but its value for identifying blood lactate threshold (LT) depends on the timing of recognizable signal changes. Two independent cohorts of 18 healthy adults completed the same incremental cycling protocol with forehead or fingertip pulse oximetry. We characterized SpO2 at key landmarks and throughout exercise and evaluated three changes: a decrease exceeding individual early-exercise variation, a rapid recent decline, and a sustained transition to a steeper decline. All detectors used only measurements available at each update. Event times were compared with Dmax and modified Dmax LT, distinguishing the sustained transition’s estimated breakpoint from its later detection. The first decrease typically preceded LT by 13–16 min. Rapid recent declines also showed substantial timing errors; requiring steeper declines reduced detection coverage. Sustained transitions were detected in 14/18 forehead and 13/18 fingertip recordings. Detection times were closer to LT than breakpoints, but median absolute detection errors remained 3.09–4.25 min across cohorts and LT definitions. Only 4–5 of 18 recordings per cohort had detection times within ±2 min of LT. Timing accuracy remained limited under alternative processing and detection settings. In a separate trajectory comparison, the fingertip cohort showed a larger SpO2 decline. Separate adjustments for exercise frequency and attained workload per kilogram of body mass reduced the estimated cohort difference, but the design could not isolate anatomical-site or sensor-configuration effects. Continuous SpO2 therefore characterized exercise-related oxygenation changes, but these three features had limited accuracy as stand-alone LT markers in healthy adults under this cycling protocol.
- Open Access
- 24 February 2026
- Published by Springer Nature in Journal of Clinical Monitoring and Computing
- Vol. 40 (4) , 1-23
Regional tissue perfusion index (RTPI): a new optical-based metric for quantifying regional tissue perfusion
Accurate, continuous assessment of regional tissue perfusion remains a significant clinical challenge, as most existing modalities are invasive, indirect, or impractical for routine monitoring. Near-infrared spectroscopy (NIRS) has been widely adopted to assess tissue oxygenation; however, conventional NIRS-derived indices are insufficient surrogates for true perfusion and often fail to capture rapid hemodynamic changes. This study aimed to introduce and validate the Regional Tissue Perfusion Index (RTPI), a novel NIRS-derived metric that integrates multiple features of the NIRS signal to provide continuous, non-invasive, and physiologically relevant assessment of tissue perfusion. RTPI was developed using principal component analysis (PCA) of multiple NIRS-derived parameters, including pulse amplitude ratio, derivative, and area under the curve. Its performance was evaluated in healthy volunteers during controlled ischemia–reperfusion protocols and compared with established reference standards, including laser Doppler flowmetry (LDF) and photoplethysmography (PPG). RTPI showed acceptable correlations with LDF Flux and PPG perfusion index (PI) during dynamic perfusion changes. Unlike conventional NIRS-derived oxygenation and hemodynamic indices, which often exhibited delayed responses, RTPI demonstrated immediate and significant sensitivity to both complete and partial ischemia–reperfusion episodes in the analyzed datasets. Intraclass correlation indicated stronger session-to-session reliability for RTPI than for both Flux and PI. RTPI represents a multiparametric, physiologically meaningful, and computationally efficient metric for real-time monitoring of tissue perfusion. Its ability to detect perfusion compromise independently of oxygenation indices highlights its translational potential for bedside implementation in critical care, trauma, perioperative, and vascular medicine, where improved diagnostic accuracy could significantly impact patient outcomes.
- 24 February 2026
- Published by Springer Nature in Journal of Clinical Monitoring and Computing
- Vol. 40 (4) , 1-23
Open AccessRegional tissue perfusion index (RTPI): a new optical-based metric for quantifying regional tissue perfusion
Accurate, continuous assessment of regional tissue perfusion remains a significant clinical challenge, as most existing modalities are invasive, indirect, or impractical for routine monitoring. Near-infrared spectroscopy (NIRS) has been widely adopted to assess tissue oxygenation; however, conventional NIRS-derived indices are insufficient surrogates for true perfusion and often fail to capture rapid hemodynamic changes. This study aimed to introduce and validate the Regional Tissue Perfusion Index (RTPI), a novel NIRS-derived metric that integrates multiple features of the NIRS signal to provide continuous, non-invasive, and physiologically relevant assessment of tissue perfusion. RTPI was developed using principal component analysis (PCA) of multiple NIRS-derived parameters, including pulse amplitude ratio, derivative, and area under the curve. Its performance was evaluated in healthy volunteers during controlled ischemia–reperfusion protocols and compared with established reference standards, including laser Doppler flowmetry (LDF) and photoplethysmography (PPG). RTPI showed acceptable correlations with LDF Flux and PPG perfusion index (PI) during dynamic perfusion changes. Unlike conventional NIRS-derived oxygenation and hemodynamic indices, which often exhibited delayed responses, RTPI demonstrated immediate and significant sensitivity to both complete and partial ischemia–reperfusion episodes in the analyzed datasets. Intraclass correlation indicated stronger session-to-session reliability for RTPI than for both Flux and PI. RTPI represents a multiparametric, physiologically meaningful, and computationally efficient metric for real-time monitoring of tissue perfusion. Its ability to detect perfusion compromise independently of oxygenation indices highlights its translational potential for bedside implementation in critical care, trauma, perioperative, and vascular medicine, where improved diagnostic accuracy could significantly impact patient outcomes.