Amir Parham Pirhadi Rad
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Amir Parham Pirhadi Rad has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
Abdolreza Jamilian
Department of Orthodontics, Faculty of Dentistry, Cranio Maxillofacial Research Center, Tehran Medical Sciences, Islamic Azad University, Tehran, Iran
1 shared publication- Ali Bashashati
University of British Columbia
1 shared publication - Babak Shadgan
Department of Orthopaedics, University of British Columbia, Vancouver, Canada
1 shared publication - Donia Sadri
Department of Oral and Maxillofacial Medicine, School of Dentistry, Islamic Azad University of Medical Sciences, Tehran, Iran
1 shared publication - Iman Amani Tehrani
Implantable Biosensing Laboratory, International Collaboration on Repair Discoveries (ICORD), Vancouver, BC V5Z 1M9, Canada
1 shared publication - Ludovica Nucci
Multidisciplinary Department of Medical-Surgical and Dental Specialties, University of Campania Luigi Vanvitelli, Naples, Italy
1 shared publication
Latest Publications
- Open Access
- 24 February 2026
- Published by Springer Nature in Journal of Clinical Monitoring and Computing
- Vol. 40 (4) , 1-23
Regional tissue perfusion index (RTPI): a new optical-based metric for quantifying regional tissue perfusion
Accurate, continuous assessment of regional tissue perfusion remains a significant clinical challenge, as most existing modalities are invasive, indirect, or impractical for routine monitoring. Near-infrared spectroscopy (NIRS) has been widely adopted to assess tissue oxygenation; however, conventional NIRS-derived indices are insufficient surrogates for true perfusion and often fail to capture rapid hemodynamic changes. This study aimed to introduce and validate the Regional Tissue Perfusion Index (RTPI), a novel NIRS-derived metric that integrates multiple features of the NIRS signal to provide continuous, non-invasive, and physiologically relevant assessment of tissue perfusion. RTPI was developed using principal component analysis (PCA) of multiple NIRS-derived parameters, including pulse amplitude ratio, derivative, and area under the curve. Its performance was evaluated in healthy volunteers during controlled ischemia–reperfusion protocols and compared with established reference standards, including laser Doppler flowmetry (LDF) and photoplethysmography (PPG). RTPI showed acceptable correlations with LDF Flux and PPG perfusion index (PI) during dynamic perfusion changes. Unlike conventional NIRS-derived oxygenation and hemodynamic indices, which often exhibited delayed responses, RTPI demonstrated immediate and significant sensitivity to both complete and partial ischemia–reperfusion episodes in the analyzed datasets. Intraclass correlation indicated stronger session-to-session reliability for RTPI than for both Flux and PI. RTPI represents a multiparametric, physiologically meaningful, and computationally efficient metric for real-time monitoring of tissue perfusion. Its ability to detect perfusion compromise independently of oxygenation indices highlights its translational potential for bedside implementation in critical care, trauma, perioperative, and vascular medicine, where improved diagnostic accuracy could significantly impact patient outcomes.
- 24 February 2026
- Published by Springer Nature in Journal of Clinical Monitoring and Computing
- Vol. 40 (4) , 1-23
Open AccessRegional tissue perfusion index (RTPI): a new optical-based metric for quantifying regional tissue perfusion
Accurate, continuous assessment of regional tissue perfusion remains a significant clinical challenge, as most existing modalities are invasive, indirect, or impractical for routine monitoring. Near-infrared spectroscopy (NIRS) has been widely adopted to assess tissue oxygenation; however, conventional NIRS-derived indices are insufficient surrogates for true perfusion and often fail to capture rapid hemodynamic changes. This study aimed to introduce and validate the Regional Tissue Perfusion Index (RTPI), a novel NIRS-derived metric that integrates multiple features of the NIRS signal to provide continuous, non-invasive, and physiologically relevant assessment of tissue perfusion. RTPI was developed using principal component analysis (PCA) of multiple NIRS-derived parameters, including pulse amplitude ratio, derivative, and area under the curve. Its performance was evaluated in healthy volunteers during controlled ischemia–reperfusion protocols and compared with established reference standards, including laser Doppler flowmetry (LDF) and photoplethysmography (PPG). RTPI showed acceptable correlations with LDF Flux and PPG perfusion index (PI) during dynamic perfusion changes. Unlike conventional NIRS-derived oxygenation and hemodynamic indices, which often exhibited delayed responses, RTPI demonstrated immediate and significant sensitivity to both complete and partial ischemia–reperfusion episodes in the analyzed datasets. Intraclass correlation indicated stronger session-to-session reliability for RTPI than for both Flux and PI. RTPI represents a multiparametric, physiologically meaningful, and computationally efficient metric for real-time monitoring of tissue perfusion. Its ability to detect perfusion compromise independently of oxygenation indices highlights its translational potential for bedside implementation in critical care, trauma, perioperative, and vascular medicine, where improved diagnostic accuracy could significantly impact patient outcomes.
- 28 July 2019
- Published by Springer Nature in Clinical Oral Investigations
- Vol. 24 (3) , 1351-1357
The effect of Alexander, Gianelly, Roth, and MBT bracket systems on anterior retraction: a 3-dimensional finite element study
Objectives The aims of this study were to compare the effect of 4 bracket systems including Alexander, Roth, MBT, and Gianelly on upper anterior retraction and to quantify the amount of torque loss ratio in sliding mechanics by help of a 3-dimensional (3D) finite element method. Method and materials 3D FEM models were constructed in order to simulate anterior incisor retraction in first premolar extraction case. Displacement, stress, and strain on the incisal edge and apex of maxillary central incisor were calculated when 1-, 2-, and 3-N retraction forces were applied. Torque loss ratio was calculated by measuring the displacement of the teeth at crown tip and root apex in all 4 bracket systems on upper central incisor. Results Uncontrolled lingual crown tipping of the incisor was observed in all bracket systems. The crown moved lingually by 9.5 μm and the root labially by 4.5 μm in MBT system with 3-N retraction force. The amount of crown movement was 8 μm and the root displacement was 4 μm in Gianelly system with the same retraction force. Torque loss ratio was 1.46 in Alexander and Gianelly with 3-N retraction force. However, the amount of torque loss ratio was 1.47 in MBT and Roth with the same retraction force. Conclusions and clinical Relevance Uncontrolled tipping was the least in Gianelly and was the highest in MBT. The amount of torque loss ratio was the lowest in Gianelly and Alexander systems and the amount of torque loss ratio was the highest in MBT system.
- 28 July 2019
- Published by Springer Nature in Clinical Oral Investigations
- Vol. 24 (3) , 1351-1357
The effect of Alexander, Gianelly, Roth, and MBT bracket systems on anterior retraction: a 3-dimensional finite element study
Objectives The aims of this study were to compare the effect of 4 bracket systems including Alexander, Roth, MBT, and Gianelly on upper anterior retraction and to quantify the amount of torque loss ratio in sliding mechanics by help of a 3-dimensional (3D) finite element method. Method and materials 3D FEM models were constructed in order to simulate anterior incisor retraction in first premolar extraction case. Displacement, stress, and strain on the incisal edge and apex of maxillary central incisor were calculated when 1-, 2-, and 3-N retraction forces were applied. Torque loss ratio was calculated by measuring the displacement of the teeth at crown tip and root apex in all 4 bracket systems on upper central incisor. Results Uncontrolled lingual crown tipping of the incisor was observed in all bracket systems. The crown moved lingually by 9.5 μm and the root labially by 4.5 μm in MBT system with 3-N retraction force. The amount of crown movement was 8 μm and the root displacement was 4 μm in Gianelly system with the same retraction force. Torque loss ratio was 1.46 in Alexander and Gianelly with 3-N retraction force. However, the amount of torque loss ratio was 1.47 in MBT and Roth with the same retraction force. Conclusions and clinical Relevance Uncontrolled tipping was the least in Gianelly and was the highest in MBT. The amount of torque loss ratio was the lowest in Gianelly and Alexander systems and the amount of torque loss ratio was the highest in MBT system.