ZOZubeida H. Omerovic

Zubeida H. Omerovic

*This is an algorithmically generated author record based on publicly available information.

Zubeida H. Omerovic has a total of 8 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Eight-year results of LASIK with or without combined accelerated crosslinking in highly myopic eyes

    by Klemens Paul Kaiser, Jakob Wend, Petra Davidova, Tyll Jandewerth, Zubeida H. Omerovic, Eva Hemkeppler, Christoph Lwowski, Myriam Böhm, Thomas Kohnen

    Purpose: To analyze the 8-year results of femtosecond laser–assisted in situ keratomileusis (LASIK) combined with simultaneous accelerated corneal crosslinking (LASIK-Xtra) compared with conventional LASIK (convLASIK). Setting: Department of Ophthalmology, Goethe-University, Frankfurt am Main, Germany. Design: Prospective, randomized fellow eye–controlled clinical trial. Methods: Patients who received randomized treatment with the LASIK-Xtra (30 mW/cm 2 , 90 seconds with continuous UV-A) in 1 eye and convLASIK in the fellow eye were subjected 1 year (pos1y), and 8 years postoperatively (pos8y) to subjective refraction, uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), endothelial cell count (ECC), biomechanical evaluation, and tomographic examination. Results: 26 eyes (−7.07 ± 1.86 diopter [D]) from 13 patients (mean age 30.7 ± 10.4 years) were included. UDVA and CDVA were insignificantly different at pos1y and pos8y between convLASIK and LASIK-Xtra (each P > .28). The safety index at pos8y was 1.09 for convLASIK and 1.15 for LASIK-Xtra ( P = .799), and the efficacy index 0.91 and 0.94 ( P = .875), respectively. Significant myopic shift in spherical equivalent between pos1y (−0.30 ± 0.40 D) and pos8y (−0.80 ± 0.86 D) was found in the convLASIK group ( P = .018), compared the LASIK-Xtra group (−0.25 ± 0.49 D and −0.40 ± 0.86 D; P = .261), respectively. However, these refractive changes cannot be fully attributed to corneal alterations alone and may also reflect other factors. Insignificant differences in mean keratometry, corneal thickness, and ECC were found at pos8y ( P > .05). The stress–strain index was the only biomechanical parameter that was significantly higher in the LASIK-Xtra group at pos8y ( P = .034). Conclusions: After 8 years, no substantial disparities in efficacy and safety indices were observed between the 2 groups. There were no substantial differences in most of the evaluated postoperative corneal biomechanical parameters between the 2 groups. However, these findings need to be validated by further studies with larger sample sizes.