Wei He
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Wei He has a total of 52 co-authors. Here are the top co-authors by number of shared publications:
- Jianxia Xiao
Jiangsu Domchamp New Material Technology Co., Ltd, Taixing City, China
3 shared publications - Shaojing Hou
Institute of High Energy Physics, Chinese Academy of Science, Beijing, China
3 shared publications - Xiao-Yan Ma
Institute of High Energy Physics
3 shared publications - Xiaohui Qian
Institute of High Energy Physics, Chinese Academy of Science, Beijing, China
3 shared publications - Xiaoyu Yang
Institute of High Energy Physics, Chinese Academy of Sciences, Beijing, China
3 shared publications - Yatian Pei
Institute of High Energy Physics, Chinese Academy of Science, Beijing, China
3 shared publications
Latest Publications
- 22 October 2026
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 1094
Rapid prediction and multi-objective optimization of mechanical response of the CEPC detector barrel yoke based on data-driven surrogate models
- 22 October 2026
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 1094
Rapid prediction and multi-objective optimization of mechanical response of the CEPC detector barrel yoke based on data-driven surrogate models
- Open Access
- 5 April 2023
- Published by Medknow in Indian Journal Of Ophthalmology
- Vol. 71 (4) , 1316-1325
Efficacy of intense pulsed light therapy on signs and symptoms of dry eye disease: A meta-analysis and systematic review
This study reviewed the efficacy and safety of intense pulsed light (IPL) for the treatment of dry eye disease (DED). The PubMed database was used to conduct the literature search, which used the keywords “intense pulsed light” and “dry eye disease”. After the authors evaluated the articles for relevancy, 49 articles were reviewed. In general, all treatment modalities were proven to be clinically effective in reducing dry eye (DE) signs and symptoms; however, the level of improvement and persistence of outcomes differed amongst them. Meta-analysis indicated significant improvement in the Ocular Surface Disease Index (OSDI) scores post-treatment with a standardized mean difference (SMD) = −1.63; confidence interval (CI): −2.42 to −0.84. Moreover, a meta-analysis indicated a significant improvement in tear break-up time (TBUT) test values with SMD = 1.77; CI: 0.49 to 3.05. Research suggests that additive therapies, such as meibomian gland expression (MGX), sodium hyaluronate eye drops, heated eye mask, warm compress, lid hygiene, lid margin scrub, eyelid massage, antibiotic drops, cyclosporine drops, omega-3 supplements, steroid drops, and warm compresses along with IPL, have been found to work in tandem for greater effectiveness; however, in clinical practice, its feasibility and cost-effectiveness have to be taken into consideration. Current findings suggest that IPL therapy is suitable when lifestyle modifications such as reducing or eliminating the use of contact lenses, lubricating eye drops/gels, and warm compresses/eye masks fail to improve signs and symptoms of DE. Moreover, patients with compliance issues have been shown to benefit well as the effects of IPL therapy is sustained for over several months. DED is a multifactorial disorder, and IPL therapy has been found to be safe and efficient in reducing its signs and symptoms of meibomian gland dysfunction (MGD)-related DE. Although the treatment protocol varies among authors, current findings suggest that IPL has a positive effect on the signs and symptoms of MGD-related DE. However, patients in the early stages can benefit more from IPL therapy. Moreover, IPL has a better maintenance impact when used in conjunction with other traditional therapies. Further research is needed to assess cost-utility analysis for IPL.
- 5 April 2023
- Published by Medknow in Indian Journal Of Ophthalmology
- Vol. 71 (4) , 1316-1325
Open AccessEfficacy of intense pulsed light therapy on signs and symptoms of dry eye disease: A meta-analysis and systematic review
This study reviewed the efficacy and safety of intense pulsed light (IPL) for the treatment of dry eye disease (DED). The PubMed database was used to conduct the literature search, which used the keywords “intense pulsed light” and “dry eye disease”. After the authors evaluated the articles for relevancy, 49 articles were reviewed. In general, all treatment modalities were proven to be clinically effective in reducing dry eye (DE) signs and symptoms; however, the level of improvement and persistence of outcomes differed amongst them. Meta-analysis indicated significant improvement in the Ocular Surface Disease Index (OSDI) scores post-treatment with a standardized mean difference (SMD) = −1.63; confidence interval (CI): −2.42 to −0.84. Moreover, a meta-analysis indicated a significant improvement in tear break-up time (TBUT) test values with SMD = 1.77; CI: 0.49 to 3.05. Research suggests that additive therapies, such as meibomian gland expression (MGX), sodium hyaluronate eye drops, heated eye mask, warm compress, lid hygiene, lid margin scrub, eyelid massage, antibiotic drops, cyclosporine drops, omega-3 supplements, steroid drops, and warm compresses along with IPL, have been found to work in tandem for greater effectiveness; however, in clinical practice, its feasibility and cost-effectiveness have to be taken into consideration. Current findings suggest that IPL therapy is suitable when lifestyle modifications such as reducing or eliminating the use of contact lenses, lubricating eye drops/gels, and warm compresses/eye masks fail to improve signs and symptoms of DE. Moreover, patients with compliance issues have been shown to benefit well as the effects of IPL therapy is sustained for over several months. DED is a multifactorial disorder, and IPL therapy has been found to be safe and efficient in reducing its signs and symptoms of meibomian gland dysfunction (MGD)-related DE. Although the treatment protocol varies among authors, current findings suggest that IPL has a positive effect on the signs and symptoms of MGD-related DE. However, patients in the early stages can benefit more from IPL therapy. Moreover, IPL has a better maintenance impact when used in conjunction with other traditional therapies. Further research is needed to assess cost-utility analysis for IPL.
- Open Access
Experimental Study on the Slip Behaviour of Stainless Steel High-Strength Bolted Connections with a New Surface Treatment
The conventional surface treatments on stainless steel plates yield slip factors less than the required value for a friction grip, which hinders the application of stainless steel high-strength bolts. The slip factor and the treatment process of stainless steel surfaces are not clearly specified in most of the existing design codes. Existing studies also show different slip factors from similarly treated surfaces. In this paper, a new surface treatment is proposed: the two touching surfaces of the bolted connection are grit-blasted on one side and coated with high-velocity oxygen fuel (HVOF) on the other side. The slip behaviour of the new method was compared with four conventional methods. The roughness and hardness of different surfaces were measured prior to a total of 30 slip tests where the slip factors of multiple stainless steel surfaces were tested. It was shown that the new proposed surface treatment method can yield a slip factor of 0.61, much higher than the conventional surface treatments, meeting the requirements as a slip-resistant connection. The preload relaxation of stainless steel high-strength bolts was also monitored and compared to standard grade 10.9 high-strength bolts. We found that the preload relaxation in stainless steel high-strength bolts is negligible.
Open AccessExperimental Study on the Slip Behaviour of Stainless Steel High-Strength Bolted Connections with a New Surface Treatment
The conventional surface treatments on stainless steel plates yield slip factors less than the required value for a friction grip, which hinders the application of stainless steel high-strength bolts. The slip factor and the treatment process of stainless steel surfaces are not clearly specified in most of the existing design codes. Existing studies also show different slip factors from similarly treated surfaces. In this paper, a new surface treatment is proposed: the two touching surfaces of the bolted connection are grit-blasted on one side and coated with high-velocity oxygen fuel (HVOF) on the other side. The slip behaviour of the new method was compared with four conventional methods. The roughness and hardness of different surfaces were measured prior to a total of 30 slip tests where the slip factors of multiple stainless steel surfaces were tested. It was shown that the new proposed surface treatment method can yield a slip factor of 0.61, much higher than the conventional surface treatments, meeting the requirements as a slip-resistant connection. The preload relaxation of stainless steel high-strength bolts was also monitored and compared to standard grade 10.9 high-strength bolts. We found that the preload relaxation in stainless steel high-strength bolts is negligible.
- 19 July 2022
- Published by Springer Nature in Nuclear Science and Techniques
- Vol. 33 (7) , 1-10
Improvement of machine learning-based vertex reconstruction for large liquid scintillator detectors with multiple types of PMTs
- 19 July 2022
- Published by Springer Nature in Nuclear Science and Techniques
- Vol. 33 (7) , 1-10
Improvement of machine learning-based vertex reconstruction for large liquid scintillator detectors with multiple types of PMTs
- 11 March 2022
- Published by Springer Nature in Radiation Detection Technology and Methods
- Vol. 6 (1) , 122-128
Research on thermoforming process of JUNO large acrylic spherical panel
- 11 March 2022
- Published by Springer Nature in Radiation Detection Technology and Methods
- Vol. 6 (1) , 122-128
Research on thermoforming process of JUNO large acrylic spherical panel
- Open Access
- 18 January 2021
- Published by Springer Nature in Research Square
Structural Design and Tensile Experiment of Connection Node between acrylic and Stainless Steel
Acrylic are widely used as load-bearing structural parts. In this study, the structural design, finite element analysis (FEA) and tensile experiment of the connection node of the acrylic spherical vessel designed for Jiangmen Underground Neutrino Observation (JUNO) are carried out. The acrylic connection node needs to withstand a tensile load of 90 kN for 20 years, and its ultimate bearing capacity is required to be 6 times the working load. Under working load, the stress of the acrylic structure should be less than 3.5 MPa. In the study, a connection node connecting acrylic and stainless steel is designed. By embedding the steel ring in the acrylic structure to connect with the support rod, the acrylic connection node can withstand high loads. A 1/4 symmetric model of connection node is established, and the FEA method is used to solve nonlinear problems such as material nonlinearity and frictional contact. The results of FEA show that the maximum principle stress of the connection node is about 2.92 MPa. By comparing the stress of the FEA results with the experimental results, the relative difference is 7.24 %, indicating that the FEA results are credible. The experiment results also show that the ultimate tensile load of the connection node can reach 1000 kN, which is about 11 times the working load. The breakdown of the connection node occurs at the sharp corner of the groove instead of the maximum stress point. Through the design, simulation and experiment of the connection node, for the brittle materials such as acrylic, the structure should avoid the defects such as sharp corner.
- 18 January 2021
- Published by Springer Nature in Research Square
Open AccessStructural Design and Tensile Experiment of Connection Node between acrylic and Stainless Steel
Acrylic are widely used as load-bearing structural parts. In this study, the structural design, finite element analysis (FEA) and tensile experiment of the connection node of the acrylic spherical vessel designed for Jiangmen Underground Neutrino Observation (JUNO) are carried out. The acrylic connection node needs to withstand a tensile load of 90 kN for 20 years, and its ultimate bearing capacity is required to be 6 times the working load. Under working load, the stress of the acrylic structure should be less than 3.5 MPa. In the study, a connection node connecting acrylic and stainless steel is designed. By embedding the steel ring in the acrylic structure to connect with the support rod, the acrylic connection node can withstand high loads. A 1/4 symmetric model of connection node is established, and the FEA method is used to solve nonlinear problems such as material nonlinearity and frictional contact. The results of FEA show that the maximum principle stress of the connection node is about 2.92 MPa. By comparing the stress of the FEA results with the experimental results, the relative difference is 7.24 %, indicating that the FEA results are credible. The experiment results also show that the ultimate tensile load of the connection node can reach 1000 kN, which is about 11 times the working load. The breakdown of the connection node occurs at the sharp corner of the groove instead of the maximum stress point. Through the design, simulation and experiment of the connection node, for the brittle materials such as acrylic, the structure should avoid the defects such as sharp corner.
- 11 August 2020
- Published by Springer Nature in Radiation Detection Technology and Methods
- Vol. 4 (3) , 345-355
Structure design and compression experiment of the supporting node for JUNO PMMA detector
- 11 August 2020
- Published by Springer Nature in Radiation Detection Technology and Methods
- Vol. 4 (3) , 345-355
Structure design and compression experiment of the supporting node for JUNO PMMA detector