David Watson
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
David Watson has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
Anjan Shah
Orthopaedic Trauma Service, Florida Orthopaedic Institute, Tampa, Florida
2 shared publicationsRafael Serrano
Department of Orthopaedics and Sports Medicine, USF Health Morsani College of Medicine, Tampa, FL
2 shared publicationsAnthony Infante
Orthopaedic Trauma Service, Florida Orthopaedic Institute, Tampa, Florida
1 shared publicationBenjamin Maxson
Orthopaedic Trauma Service, Florida Orthopaedic Institute, Tampa, Florida
1 shared publicationBrian Kistler
Upstate Orthopedics, Syracuse, NY
1 shared publicationDarryl A. Auston
Florida Orthopaedic Institute, Orthopaedic Trauma Service, Tampa General Hospital, Tampa, FL; †Upstate Orthopedics, Syracuse, NY; ‡University of South Florida School of Medicine, Tampa, FL; and §Hughston Trauma, Fort Walton Beach, FL
1 shared publication
Latest Publications
- 1 November 2019
- Published by Wolters Kluwer Health in Journal of Orthopaedic Trauma
- Vol. 33 (11) , 559-563
Effect of Nail Size, Insertion, and Δ Canal-Nail on the Development of a Nonunion After Intramedullary Nailing of Femoral Shaft Fractures
Objective: To determine whether intramedullary nail (IMN) diameter, antegrade versus retrograde insertion, or the difference between the canal and IMN diameter affect femoral shaft fracture healing. Design: Retrospective analysis of a prospective database. Setting: Level One Regional Trauma Center. Patients/Participants: Seven hundred thirty-three femoral shaft fractures (OTA/AO 32) treated with an IMN between 1999 and 2017. After exclusion criteria, 484 fractures remained in the final analysis. Intervention: Closed section, cannulated, interlocked, titanium alloy IMN using a reamed insertion technique. Main Outcome Measurements: Nonunion, IMN size (10, 11.5, and 13 mm), antegrade versus retrograde insertion, Δ canal-nail diameter (ΔD) after reaming (2 mm). Results: IMN diameters used were as follows: 314/10 mm (64%), 137/11.5 mm (28%), and 33/13 mm (8%). Forty-five percent were placed in antegrade versus 55% retrograde. Four hundred fifty-six fractures (94.2%) healed uneventfully. There were no IMN failures. 10/484 IMNs (2%) had broken interlocking screws; only 4 were associated with a NU. Average time to union was 23 weeks (12–119). Twenty-eight (5.8%) developed NU. There was no statistical correlation between (1) the NU rate and IMN diameter: 10 mm, 6.3%; 11.5 mm, 5.1%; 13 mm, 3% (P = 0.8, power = 0.85), (2) the NU rate and ΔD: 7.1% 2 mm (P = 0.36), (3) the NU rate and fracture location: Prox = 11%, Mid = 5%, Dist = 3% (P = 0.13), or (4) the NU rate and antegrade (7.2%) versus retrograde (4.2%) insertion (P = 0.24). Conclusion: Similar healing rates occurred regardless of IMN diameter, Δ canal-nail diameter after reaming, or insertion site. This indicates that a closed section, cannulated, interlocked, titanium alloy IMN with a diameter of 10 mm can be considered the standard diameter for the treatment of acute femoral shaft fractures, regardless of entry point. This should be associated with less reaming and therefore shorter operative times, and possibly less hospital implant inventories as well. Larger diameter IMN should be reserved for revision surgery. Level of Evidence: Therapeutic Level III. See Instructions for Authors for a complete description of levels of evidence.
- 1 November 2019
- Published by Wolters Kluwer Health in Journal of Orthopaedic Trauma
- Vol. 33 (11) , 559-563
Effect of Nail Size, Insertion, and Δ Canal-Nail on the Development of a Nonunion After Intramedullary Nailing of Femoral Shaft Fractures
Objective: To determine whether intramedullary nail (IMN) diameter, antegrade versus retrograde insertion, or the difference between the canal and IMN diameter affect femoral shaft fracture healing. Design: Retrospective analysis of a prospective database. Setting: Level One Regional Trauma Center. Patients/Participants: Seven hundred thirty-three femoral shaft fractures (OTA/AO 32) treated with an IMN between 1999 and 2017. After exclusion criteria, 484 fractures remained in the final analysis. Intervention: Closed section, cannulated, interlocked, titanium alloy IMN using a reamed insertion technique. Main Outcome Measurements: Nonunion, IMN size (10, 11.5, and 13 mm), antegrade versus retrograde insertion, Δ canal-nail diameter (ΔD) after reaming (2 mm). Results: IMN diameters used were as follows: 314/10 mm (64%), 137/11.5 mm (28%), and 33/13 mm (8%). Forty-five percent were placed in antegrade versus 55% retrograde. Four hundred fifty-six fractures (94.2%) healed uneventfully. There were no IMN failures. 10/484 IMNs (2%) had broken interlocking screws; only 4 were associated with a NU. Average time to union was 23 weeks (12–119). Twenty-eight (5.8%) developed NU. There was no statistical correlation between (1) the NU rate and IMN diameter: 10 mm, 6.3%; 11.5 mm, 5.1%; 13 mm, 3% (P = 0.8, power = 0.85), (2) the NU rate and ΔD: 7.1% 2 mm (P = 0.36), (3) the NU rate and fracture location: Prox = 11%, Mid = 5%, Dist = 3% (P = 0.13), or (4) the NU rate and antegrade (7.2%) versus retrograde (4.2%) insertion (P = 0.24). Conclusion: Similar healing rates occurred regardless of IMN diameter, Δ canal-nail diameter after reaming, or insertion site. This indicates that a closed section, cannulated, interlocked, titanium alloy IMN with a diameter of 10 mm can be considered the standard diameter for the treatment of acute femoral shaft fractures, regardless of entry point. This should be associated with less reaming and therefore shorter operative times, and possibly less hospital implant inventories as well. Larger diameter IMN should be reserved for revision surgery. Level of Evidence: Therapeutic Level III. See Instructions for Authors for a complete description of levels of evidence.
- 1 April 2017
- Published by Wolters Kluwer Health in Journal of Orthopaedic Trauma
- Vol. 31 (4) , 215-219
Percutaneous or Open Reduction of Closed Tibial Shaft Fractures During Intramedullary Nailing Does Not Increase Wound Complications, Infection or Nonunion Rates
Objective: To compare the incidence of complications (wound, infection, and nonunion) among those patients treated with closed, percutaneous, and open intramedullary nailing for closed tibial shaft fractures. Design: Retrospective review. Setting: Multiple trauma centers. Patients: Skeletally mature patients with closed tibia fractures amenable to treatment with an intramedullary device. Intervention: Intramedullary fixation with closed, percutaneous, or open reduction. Main Outcome Measurements: Superficial wound complication, deep infection, nonunion. Results: A total of 317 tibial shaft fractures in 315 patients were included in the study. Two-hundred fractures in 198 patients were treated with closed reduction, 61 fractures in 61 patients were treated with percutaneous reduction, and 56 fractures in 56 patients were treated with formal open reduction. The superficial wound complication rate was 1% (2/200) for the closed group, 1.6% (1/61) for the percutaneous group, and 3.6% (2/56) for the open group with no statistical difference between the groups (P = 0.179). The deep infection rate was 2% (4/200) for the closed group, 1.6% (1/61) for the percutaneous group, and 7.1% (4/56) for the open group with no significant difference between the groups (P = 0.133). Nonunion rate was 5.0% (10/200) for the closed group, 4.9% (3/61) for the percutaneous group, and 7.1% (4/56) for the open group, with no statistical difference between the groups (P = 0.492). Conclusions: This is the largest reported series of closed tibial shaft fractures nailed with percutaneous and open reduction. Percutaneous or open reduction did not result in increased wound complications, infection, or nonunion rates. Carefully performed percutaneous or open approaches can be safely used in obtaining reduction of difficult tibial shaft fractures treated with intramedullary devices. Level of Evidence: Therapeutic Level III. See Instructions for Authors for a complete description of levels of evidence.
- 1 April 2017
- Published by Wolters Kluwer Health in Journal of Orthopaedic Trauma
- Vol. 31 (4) , 215-219
Percutaneous or Open Reduction of Closed Tibial Shaft Fractures During Intramedullary Nailing Does Not Increase Wound Complications, Infection or Nonunion Rates
Objective: To compare the incidence of complications (wound, infection, and nonunion) among those patients treated with closed, percutaneous, and open intramedullary nailing for closed tibial shaft fractures. Design: Retrospective review. Setting: Multiple trauma centers. Patients: Skeletally mature patients with closed tibia fractures amenable to treatment with an intramedullary device. Intervention: Intramedullary fixation with closed, percutaneous, or open reduction. Main Outcome Measurements: Superficial wound complication, deep infection, nonunion. Results: A total of 317 tibial shaft fractures in 315 patients were included in the study. Two-hundred fractures in 198 patients were treated with closed reduction, 61 fractures in 61 patients were treated with percutaneous reduction, and 56 fractures in 56 patients were treated with formal open reduction. The superficial wound complication rate was 1% (2/200) for the closed group, 1.6% (1/61) for the percutaneous group, and 3.6% (2/56) for the open group with no statistical difference between the groups (P = 0.179). The deep infection rate was 2% (4/200) for the closed group, 1.6% (1/61) for the percutaneous group, and 7.1% (4/56) for the open group with no significant difference between the groups (P = 0.133). Nonunion rate was 5.0% (10/200) for the closed group, 4.9% (3/61) for the percutaneous group, and 7.1% (4/56) for the open group, with no statistical difference between the groups (P = 0.492). Conclusions: This is the largest reported series of closed tibial shaft fractures nailed with percutaneous and open reduction. Percutaneous or open reduction did not result in increased wound complications, infection, or nonunion rates. Carefully performed percutaneous or open approaches can be safely used in obtaining reduction of difficult tibial shaft fractures treated with intramedullary devices. Level of Evidence: Therapeutic Level III. See Instructions for Authors for a complete description of levels of evidence.