Zhe Su
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Zhe Su has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
Dejia Ding
Shenzhen Dacheng Precision Equipment Co., Ltd., 518000, Shenzhen, China
1 shared publicationQingbao Fu
MicroParity Tech Inc, 310051, Hangzhou, China
1 shared publication- Rong Zhou
College of physics, Sichuan University, Chengdu 610065, China
1 shared publication Shu Sun
Shenzhen Dacheng Precision Equipment Co., Ltd., 518000, Shenzhen, China
1 shared publicationShuaibin Ding
MicroParity Tech Inc, 310051, Hangzhou, China
1 shared publicationWei Shen
MicroParity Tech Inc, 310051, Hangzhou, China
1 shared publication
Latest Publications
- 1 March 2026
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 21 (03) , P03006
Areal density measurement of overlapping materials based on a photon-counting detector
Accurate quantification of areal density in overlapping thin-film materials is essential for evaluating and controlling the performance of multilayer electrodes in lithium-ion batteries. In this study, a dual-energy X-ray absorptiometry method based on a silicon pixel photon-counting detector (PCD) is proposed to simultaneously measure the areal densities of two overlapping materials. By utilizing the adjustable electronic thresholds of the MPI501 PCD, the incident X-ray spectrum is divided into two optimized energy intervals, determined through Nordfors, NSR Δ t , and SNR criteria. Monte Carlo simulations conducted in Geant4 were employed to optimize detector thresholds, while experimental verification was performed using LiFePO 4 (LFP) and LiNi 0.8 Co 0.1 Mn 0.1 O 2 (NMC) multilayer electrodes. Under a 20 kV X-ray tube voltage and detector thresholds set to 4 keV and 8 keV, the proposed method achieved mean standard deviations of 1.25 g/m 2 for LFP and 0.67 g/m 2 for NMC, with RMSE values below 2.5 g/m 2 . The results confirm the feasibility of this non-destructive technique for high-precision areal density measurement.
- 1 March 2026
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 21 (03) , P03006
Areal density measurement of overlapping materials based on a photon-counting detector
Accurate quantification of areal density in overlapping thin-film materials is essential for evaluating and controlling the performance of multilayer electrodes in lithium-ion batteries. In this study, a dual-energy X-ray absorptiometry method based on a silicon pixel photon-counting detector (PCD) is proposed to simultaneously measure the areal densities of two overlapping materials. By utilizing the adjustable electronic thresholds of the MPI501 PCD, the incident X-ray spectrum is divided into two optimized energy intervals, determined through Nordfors, NSR Δ t , and SNR criteria. Monte Carlo simulations conducted in Geant4 were employed to optimize detector thresholds, while experimental verification was performed using LiFePO 4 (LFP) and LiNi 0.8 Co 0.1 Mn 0.1 O 2 (NMC) multilayer electrodes. Under a 20 kV X-ray tube voltage and detector thresholds set to 4 keV and 8 keV, the proposed method achieved mean standard deviations of 1.25 g/m 2 for LFP and 0.67 g/m 2 for NMC, with RMSE values below 2.5 g/m 2 . The results confirm the feasibility of this non-destructive technique for high-precision areal density measurement.