Jun Ken Gan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Jun Ken Gan has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
- Hong Qi Tan
Division of Radiation Oncology, National Cancer Centre Singapore, Singapore; Division of Physics and Applied Physics, School of Physical and Mathematical Science, Nanyang Technological University, Singapore; Oncology Academic Clinical Programme, Duke-NUS Medical School, Singapore
3 shared publications James Cheow Lei Lee
School of Physical and Mathematical Sciences, Nanyang Technological University
3 shared publicationsKah Seng Lew
School of Physical and Mathematical Sciences, Nanyang Technological University
3 shared publications- Sung Yong Park
National Cancer Centre Singapore
3 shared publications Andrew Wibawa
National Cancer Centre Singapore
2 shared publications- Clifford Ghee Ann Chua
Division of Physics and Applied Physics School of Physical and Mathematical Science Nanyang Technological University Singapore Singapore
2 shared publications
Latest Publications
- 26 October 2026
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 71 (20) , 205031
A generalized phenomenological model of oxygen depletion for FLASH particle radiotherapy: evidence from in vitro data
Objective. Ultra-high dose rate (uHDR: FLASH) radiotherapy reduces normal tissue toxicity while preserving tumor control. The oxygen depletion hypothesis posits that rapid oxygen consumption during FLASH irradiation transiently reduces radiosensitivity. However, experimental measurements suggest oxygen depletion may be limited, particularly under normoxia. This study quantitatively assesses the adequacy of this hypothesis in reproducing experimentally observed sparing effects by comparing mechanistic simulations with in vitro cell survival data across a wide range of irradiation conditions. Approach. We developed a phenomenological framework for radiolytic oxygen depletion incorporating temporal dose delivery, dose rate, and linear energy transfer (LET). LET dependence was included through oxygen consumption efficiency and the maximum oxygen enhancement ratio. For direct comparison, simulation results were linked to clonogenic cell survival using a damage reduction factor (DRF) derived from the linear-quadratic model. Simulated DRFs were compared with experimental DRFs from six independent in vitro studies involving electrons, protons, helium ions, and carbon ions over broad ranges of LET, oxygenation, and dose rates using parity plots, residual analyses, stratified weighted statistics, and correlation analyses. Main results. Under most irradiation conditions, simulated DRFs remained close to unity (minimum values approximately 0.96), indicating limited predicted protection from oxygen depletion. Conversely, experimental DRFs exhibited substantially larger deviations. Stratified analyses revealed systematic discrepancies between simulated and experimental DRFs across oxygenation, LET, and dose rate, with pronounced disagreement under normoxia, high LET, and uHDRs. Residual analyses demonstrated underestimation of the sparing effect by the model. Correlation analyses showed statistically insignificant associations between simulated and experimental metrics. Significance. The oxygen depletion model considered in this work insufficiently reproduces the observed sparing effect under the in vitro conditions considered. Additional biological and physicochemical mechanisms likely play a significant role. This framework provides a quantitative basis for evaluating alternative mechanisms and integrating future experimental data toward a more complete understanding of FLASH radiotherapy.
- 26 October 2026
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 71 (20) , 205031
A generalized phenomenological model of oxygen depletion for FLASH particle radiotherapy: evidence from in vitro data
Objective. Ultra-high dose rate (uHDR: FLASH) radiotherapy reduces normal tissue toxicity while preserving tumor control. The oxygen depletion hypothesis posits that rapid oxygen consumption during FLASH irradiation transiently reduces radiosensitivity. However, experimental measurements suggest oxygen depletion may be limited, particularly under normoxia. This study quantitatively assesses the adequacy of this hypothesis in reproducing experimentally observed sparing effects by comparing mechanistic simulations with in vitro cell survival data across a wide range of irradiation conditions. Approach. We developed a phenomenological framework for radiolytic oxygen depletion incorporating temporal dose delivery, dose rate, and linear energy transfer (LET). LET dependence was included through oxygen consumption efficiency and the maximum oxygen enhancement ratio. For direct comparison, simulation results were linked to clonogenic cell survival using a damage reduction factor (DRF) derived from the linear-quadratic model. Simulated DRFs were compared with experimental DRFs from six independent in vitro studies involving electrons, protons, helium ions, and carbon ions over broad ranges of LET, oxygenation, and dose rates using parity plots, residual analyses, stratified weighted statistics, and correlation analyses. Main results. Under most irradiation conditions, simulated DRFs remained close to unity (minimum values approximately 0.96), indicating limited predicted protection from oxygen depletion. Conversely, experimental DRFs exhibited substantially larger deviations. Stratified analyses revealed systematic discrepancies between simulated and experimental DRFs across oxygenation, LET, and dose rate, with pronounced disagreement under normoxia, high LET, and uHDRs. Residual analyses demonstrated underestimation of the sparing effect by the model. Correlation analyses showed statistically insignificant associations between simulated and experimental metrics. Significance. The oxygen depletion model considered in this work insufficiently reproduces the observed sparing effect under the in vitro conditions considered. Additional biological and physicochemical mechanisms likely play a significant role. This framework provides a quantitative basis for evaluating alternative mechanisms and integrating future experimental data toward a more complete understanding of FLASH radiotherapy.
- 10 May 2026
- Published by Wiley in Medical Physics
- Vol. 53 (5) , e70466
Ion recombination correction in reference dosimetry for pencil beam scanned proton beams
Background: The 2024 IAEA TRS‐398 revision updated recommendations for reference dosimetry and ion recombination corrections in pencil beam scanned (PBS) proton beams. Purpose: This study evaluates the revised ion recombination methods for monoenergetic synchrotron‐based PBS proton system across different energies, monitor units (MU), and ionization chamber types. Methods: Reference‐field measurements were performed using a synchrotron system at 70.2, 150.2, and 228.7 MeV and at 6, 50, and 200 MU. Charge‐collection data were acquired using PTW Farmer and Advanced Markus chambers across 20–400 V. Ion recombination correction factors () were determined using the Jaffé plot extrapolation method and the TRS‐398 two‐voltage method (TVM) under different time structure assumptions. Charge multiplication in the chamber was addressed using both low voltage linear fitting and a semiempirical exponential model. Results: For low energy, low MU fields, and TVM yielded values within ∼1% of the Jaffé extrapolation. For high‐energy, high‐MU fields, maximum differences of 6.25% (Farmer) and 1.62% (Advanced Markus) were observed. The synchrotron beam exhibited energy, MU, and chamber dependent time structure behavior, producing pulsed‐like or continuous‐like characteristics. Misclassification of the time structure resulted in additional deviations of up to 2.49% (Farmer) and 0.59% (Advanced Markus). Charge multiplication was observed in the Advanced Markus chamber at voltages > 150 V. The exponential fitting successfully modeled this response and produced values agreeing with low voltage fits within 1.5%, while avoiding subjective voltage cutoff selection. Conclusion: The revised TRS‐398 provides accurate ion recombination corrections for monoenergetic PBS fields at low energies and low MU. However, accuracy of ion recombination correction decreases at higher energies and MU, particularly when the time structure was ambiguous or chamber dependent. Charge multiplication in small volume chambers presents an additional source of uncertainty not fully addressed by TRS‐398. Incorporating charge multiplication fitting methods may improve the robustness of reference dosimetry in synchrotron‐based PBS proton therapy.
- 10 May 2026
- Published by Wiley in Medical Physics
- Vol. 53 (5) , e70466
Ion recombination correction in reference dosimetry for pencil beam scanned proton beams
Background: The 2024 IAEA TRS‐398 revision updated recommendations for reference dosimetry and ion recombination corrections in pencil beam scanned (PBS) proton beams. Purpose: This study evaluates the revised ion recombination methods for monoenergetic synchrotron‐based PBS proton system across different energies, monitor units (MU), and ionization chamber types. Methods: Reference‐field measurements were performed using a synchrotron system at 70.2, 150.2, and 228.7 MeV and at 6, 50, and 200 MU. Charge‐collection data were acquired using PTW Farmer and Advanced Markus chambers across 20–400 V. Ion recombination correction factors () were determined using the Jaffé plot extrapolation method and the TRS‐398 two‐voltage method (TVM) under different time structure assumptions. Charge multiplication in the chamber was addressed using both low voltage linear fitting and a semiempirical exponential model. Results: For low energy, low MU fields, and TVM yielded values within ∼1% of the Jaffé extrapolation. For high‐energy, high‐MU fields, maximum differences of 6.25% (Farmer) and 1.62% (Advanced Markus) were observed. The synchrotron beam exhibited energy, MU, and chamber dependent time structure behavior, producing pulsed‐like or continuous‐like characteristics. Misclassification of the time structure resulted in additional deviations of up to 2.49% (Farmer) and 0.59% (Advanced Markus). Charge multiplication was observed in the Advanced Markus chamber at voltages > 150 V. The exponential fitting successfully modeled this response and produced values agreeing with low voltage fits within 1.5%, while avoiding subjective voltage cutoff selection. Conclusion: The revised TRS‐398 provides accurate ion recombination corrections for monoenergetic PBS fields at low energies and low MU. However, accuracy of ion recombination correction decreases at higher energies and MU, particularly when the time structure was ambiguous or chamber dependent. Charge multiplication in small volume chambers presents an additional source of uncertainty not fully addressed by TRS‐398. Incorporating charge multiplication fitting methods may improve the robustness of reference dosimetry in synchrotron‐based PBS proton therapy.
- Open Access
- 7 February 2026
- Published by Elsevier in International Journal of Particle Therapy
- Vol. 19
Commissioning of LUNA three-dimensional surface-guided radiotherapy in full rotating gantry proton therapy system
- 7 February 2026
- Published by Elsevier in International Journal of Particle Therapy
- Vol. 19
Open AccessCommissioning of LUNA three-dimensional surface-guided radiotherapy in full rotating gantry proton therapy system