Rekha Pathak
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Rekha Pathak has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Abhishek Chandra Saxena
Division of Surgery Indian Veterinary Research Institute Bareilly India
2 shared publications - Aman Kumar Tiwari
Division of Surgery Indian Veterinary Research Institute Bareilly India
2 shared publications - Amar Pal
Division of Surgery, ICAR-Indian Veterinary Research Institute, Bareilly, India
2 shared publications - Kuskur Sannappa Naik Kamalesh Kumar
Division of Surgery Indian Veterinary Research Institute Bareilly India
2 shared publications - T. Sai Kumar
Division of Surgery Indian Veterinary Research Institute Bareilly India
2 shared publications - Abhijit Motiram Pawde
Division of Surgery ICAR‐Indian Veterinary Research Institute Bareilly Uttar Pradesh India
1 shared publication
Latest Publications
- 16 November 2026
- Published by Wiley in Veterinary Surgery
Comparative biomechanical study of a novel variable diameter circular external fixation device ( VDCF ) for stabilizing a simulated tibial fracture gap in bovine cadaver specimens
Objective: To compare the biomechanical performance of a novel variable diameter circular external fixation device (VDCF) with a conventional circular external fixator (CEF) using a standardized osteotomized buffalo tibia model under axial compression and torsional loading. Study design: Experimental in vitro biomechanical comparative study. Sample population: A total of 36 adult bovine tibiae obtained postmortem from buffaloes. Methods: The tibiae were randomly allocated into three groups ( n = 12 each): VDCF, CEF, and intact bone. A standardized mid‐diaphyseal transverse osteotomy with a 20 mm gap was created to simulate an unstable fracture model. Constructs were subjected to axial compression and torsional testing to failure using displacement‐controlled protocols. Key biomechanical parameters evaluated included failure load, axial stiffness, and maximum torque derived from load–deformation curves. Statistical analysis was performed using one‐way ANOVA followed by Tukey's HSD test. Results: Intact tibiae demonstrated significantly greater failure load and axial stiffness than both fixation constructs ( p < .05). No significant differences were detected between VDCF and CEF in failure load or axial stiffness ( p > .05). During torsional testing, maximum torque did not differ significantly between constructs ( p > .05); however, VDCF exhibited significantly greater torsional stiffness than CEF ( p < .05). Failure modes were primarily characterized by plastic deformation and wire bending in both constructs, while fixation‐bolt loosening was observed only in the CEF group. Conclusion: The VDCF showed no significant differences compared with conventional circular external fixation in failure load, axial stiffness, maximum torque, and torsional strength, while exhibiting significantly greater torsional stiffness under the experimental conditions. Clinical significance/impact: The VDCF represents a potential alternative fixation configuration with practical advantages in construct adaptability and cost for fracture stabilization in large animals.
- 16 November 2026
- Published by Wiley in Veterinary Surgery
Comparative biomechanical study of a novel variable diameter circular external fixation device ( VDCF ) for stabilizing a simulated tibial fracture gap in bovine cadaver specimens
Objective: To compare the biomechanical performance of a novel variable diameter circular external fixation device (VDCF) with a conventional circular external fixator (CEF) using a standardized osteotomized buffalo tibia model under axial compression and torsional loading. Study design: Experimental in vitro biomechanical comparative study. Sample population: A total of 36 adult bovine tibiae obtained postmortem from buffaloes. Methods: The tibiae were randomly allocated into three groups ( n = 12 each): VDCF, CEF, and intact bone. A standardized mid‐diaphyseal transverse osteotomy with a 20 mm gap was created to simulate an unstable fracture model. Constructs were subjected to axial compression and torsional testing to failure using displacement‐controlled protocols. Key biomechanical parameters evaluated included failure load, axial stiffness, and maximum torque derived from load–deformation curves. Statistical analysis was performed using one‐way ANOVA followed by Tukey's HSD test. Results: Intact tibiae demonstrated significantly greater failure load and axial stiffness than both fixation constructs ( p < .05). No significant differences were detected between VDCF and CEF in failure load or axial stiffness ( p > .05). During torsional testing, maximum torque did not differ significantly between constructs ( p > .05); however, VDCF exhibited significantly greater torsional stiffness than CEF ( p < .05). Failure modes were primarily characterized by plastic deformation and wire bending in both constructs, while fixation‐bolt loosening was observed only in the CEF group. Conclusion: The VDCF showed no significant differences compared with conventional circular external fixation in failure load, axial stiffness, maximum torque, and torsional strength, while exhibiting significantly greater torsional stiffness under the experimental conditions. Clinical significance/impact: The VDCF represents a potential alternative fixation configuration with practical advantages in construct adaptability and cost for fracture stabilization in large animals.
- 28 February 2026
- Published by Wiley in Anatomia, Histologia, Embryologia
- Vol. 55 (2)
Radiographic Morphometry of the Proximal Femur and Hip Joint in Spitz Breed Dogs: Establishing Breed‐Specific Reference Values
Variations in hip joint morphology are clinically important because they influence both the diagnosis of orthopaedic disease and the success of surgical interventions. Establishing breed‐ and gender‐specific reference values is therefore essential for understanding normal canine hip anatomy and its variations. The present study aimed to provide radiographic morphometric reference data for the proximal femur and acetabulum in healthy Spitz breed dogs. Sixty adult dogs (30 males, 30 females) underwent standardised ventrodorsal extended hip radiographs under general anaesthesia. Acetabular and femoral morphological parameters were measured, and mean ± SD values were compared between genders and between left and right sides. Most parameters showed no significant differences across groups; however, femoral length, femoral neck length, and right‐sided acetabular offset differed significantly between genders. Combined acetabular parameters (depth index, centre‐edge angle) also showed gender‐specific variation, whereas combined femoral parameters did not. These results provide the first comprehensive radiographic morphometric dataset for the Spitz breed and demonstrate subtle gender‐related differences with minimal left–right asymmetry. We hypothesise that these reference values will support future comparative morphometric studies and contribute to preclinical orthopaedic research, while offering a foundation for the potential development of breed‐specific surgical planning tools.
- 28 February 2026
- Published by Wiley in Anatomia, Histologia, Embryologia
- Vol. 55 (2)
Radiographic Morphometry of the Proximal Femur and Hip Joint in Spitz Breed Dogs: Establishing Breed‐Specific Reference Values
Variations in hip joint morphology are clinically important because they influence both the diagnosis of orthopaedic disease and the success of surgical interventions. Establishing breed‐ and gender‐specific reference values is therefore essential for understanding normal canine hip anatomy and its variations. The present study aimed to provide radiographic morphometric reference data for the proximal femur and acetabulum in healthy Spitz breed dogs. Sixty adult dogs (30 males, 30 females) underwent standardised ventrodorsal extended hip radiographs under general anaesthesia. Acetabular and femoral morphological parameters were measured, and mean ± SD values were compared between genders and between left and right sides. Most parameters showed no significant differences across groups; however, femoral length, femoral neck length, and right‐sided acetabular offset differed significantly between genders. Combined acetabular parameters (depth index, centre‐edge angle) also showed gender‐specific variation, whereas combined femoral parameters did not. These results provide the first comprehensive radiographic morphometric dataset for the Spitz breed and demonstrate subtle gender‐related differences with minimal left–right asymmetry. We hypothesise that these reference values will support future comparative morphometric studies and contribute to preclinical orthopaedic research, while offering a foundation for the potential development of breed‐specific surgical planning tools.