ZJZiyang Jia
Ziyang Jia
*This is an algorithmically generated author record based on publicly available information.
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Ziyang Jia has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Bingheng Yan
Jinan Inspur Data Company Ltd., Jinan, China
1 shared publication - Dong Zhang
Inspur Data Technology Co, Ltd, Jinan, Shandong, China
1 shared publication - Fangming Liu
Huazhong University of Science and Technology, Wuhan, China
1 shared publication - Fei Xu
East China Normal University
1 shared publication - Qiangyu Pei
National Engineering Research Center for Big Data Technology and System, Services Computing Technology and System Lab, Cluster and Grid Computing Lab, School of Computer Science and Technology, Huazhong University of Science and Technology, Wuhan, China
1 shared publication - Qixia Zhang
National Engineering Research Center for Big Data Technology and System, the Services Computing Technology and System Lab, Huazhong University of Science and Technology, Wuhan, China
1 shared publication
Latest Publications
- 14 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Computers
- Vol. 75 (4) , 1518-1532
Cooling as You Wish: Component-Level Cooling for Heterogeneous Edge Datacenters
As computing shifts toward the edge, edge datacenters are becoming essential for supporting diverse real-time applications. Unlike traditional cloud datacenters, edge datacenters face unique cooling challenges due to their requirements for proximity to end users, high density, and hardware heterogeneity. While warm water cooling is a promising technique for this infrastructure, current one-size-fits-all cooling strategies significantly compromise efficiency due to severe inter- and intra-component hotspots. In this work, we present CoolEdge${}^{+}$ , a cost-effective component-level water cooling system for enhancing the cooling efficiency of edge datacenters. Specifically, CoolEdge${}^{+}$ dynamically adjusts the inlet water temperature for each component through a carefully designed water circulation architecture to mitigate inter-component hotspots. To address intra-component hotspots, it employs vapor chamber–based cold plates that rapidly dissipate heat without manual intervention or additional energy consumption. We further design a fine-grained cooling control framework that leverages a well-managed power capping approach to decide on customized inlet water temperatures and hardware power limits. Based on a hardware prototype and a real-world trace from Alibaba PAI, evaluation results show that CoolEdge${}^{+}$ reduces cooling energy consumption by up to 27.19% compared to existing coarse-grained systems, while maintaining performance guarantees. Compared to the state-of-the-art CoolEdge, CoolEdge${}^{+}$ saves 35.24% more cooling costs with comparable energy consumption and no latency violations.- 14 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Computers
- Vol. 75 (4) , 1518-1532
Cooling as You Wish: Component-Level Cooling for Heterogeneous Edge Datacenters
As computing shifts toward the edge, edge datacenters are becoming essential for supporting diverse real-time applications. Unlike traditional cloud datacenters, edge datacenters face unique cooling challenges due to their requirements for proximity to end users, high density, and hardware heterogeneity. While warm water cooling is a promising technique for this infrastructure, current one-size-fits-all cooling strategies significantly compromise efficiency due to severe inter- and intra-component hotspots. In this work, we present CoolEdge${}^{+}$ , a cost-effective component-level water cooling system for enhancing the cooling efficiency of edge datacenters. Specifically, CoolEdge${}^{+}$ dynamically adjusts the inlet water temperature for each component through a carefully designed water circulation architecture to mitigate inter-component hotspots. To address intra-component hotspots, it employs vapor chamber–based cold plates that rapidly dissipate heat without manual intervention or additional energy consumption. We further design a fine-grained cooling control framework that leverages a well-managed power capping approach to decide on customized inlet water temperatures and hardware power limits. Based on a hardware prototype and a real-world trace from Alibaba PAI, evaluation results show that CoolEdge${}^{+}$ reduces cooling energy consumption by up to 27.19% compared to existing coarse-grained systems, while maintaining performance guarantees. Compared to the state-of-the-art CoolEdge, CoolEdge${}^{+}$ saves 35.24% more cooling costs with comparable energy consumption and no latency violations.