Alaa Tariq Shukri
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Alaa Tariq Shukri has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Atif Ali Hasan
Department of Mechanical Power Technical, Institute of Technology/ Baghdad, Middle Technical University, Iraq
2 shared publications - Aveen M. Abdulwahaab
Department of Mechanical Techniques, Kirkuk Polytechnic College, Northern Technical University, Kirkuk, 36001, Iraq
2 shared publications - Hadeel A. Hasan
Department of Control and Automation, Electrical Technical College, Middle Technical University, Baghdad, Iraq
2 shared publications - Omer Adil Zainal
Mechanical Engineering Department, College of Engineering, University of Kirkuk, Kirkuk, Iraq
2 shared publications - Mahmood Hussain Khaleel
Department of Mechanical Power Technical, Kirkuk Technical Institute Northern Technical University Kirkuk Iraq
1 shared publication
Latest Publications
- Open Access
- 5 November 2026
- Published by Akademiai Kiado Zrt. in International Review of Applied Sciences and Engineering
- Vol. 17 (3) , 356-366
An experimental study to improve wall thermal performance in Iraqi buildings utilizing several types of perforated bricks
Climate change, rising global surface temperatures, and global warming pose significant environmental and human challenges. These environmental changes negatively impact weather patterns and ambient temperatures, affecting the amount of heat transferred to buildings in summer and lost in winter. Maintaining standard indoor temperatures requires electricity consumption through air conditioning. Researchers are working to address these challenges to protect the environment and human health, reduce electricity consumption, and meet sustainability requirements in the Iraqi construction sector. Traditional Iraqi clay bricks, shaped with various geometric patterns and perforations, were tested to improve their thermal performance and compare it to solid, non-perforated bricks. The experiments were conducted in a 1 × 1 × 2 m test chamber, insulated on all sides except the eastern side, where the test wall is located, which is exposed to external weather conditions and sunlight. An air conditioning unit was installed inside the test chamber to maintain the standard temperature during the tests. These perforated clay bricks, available in 25 and 35 mm diameters, demonstrated excellent thermal performance, reducing heat loads and minimizing the need for cooling during building renovations, thus lowering air conditioning energy consumption. These bricks exhibited the highest energy savings, resulting in an estimated 24 and 25% reduction, respectively, in thermal energy penetration into buildings. The thermal test of the highest energy-reducing bricks was conducted by sealing the 35 mm diameter holes with plastic plugs at both ends of each hole. This means that the air volume that filled the holes was reduced significantly, resulting in a 40% increase in energy reduction compared to solid bricks.
- 5 November 2026
- Published by Akademiai Kiado Zrt. in International Review of Applied Sciences and Engineering
- Vol. 17 (3) , 356-366
Open AccessAn experimental study to improve wall thermal performance in Iraqi buildings utilizing several types of perforated bricks
Climate change, rising global surface temperatures, and global warming pose significant environmental and human challenges. These environmental changes negatively impact weather patterns and ambient temperatures, affecting the amount of heat transferred to buildings in summer and lost in winter. Maintaining standard indoor temperatures requires electricity consumption through air conditioning. Researchers are working to address these challenges to protect the environment and human health, reduce electricity consumption, and meet sustainability requirements in the Iraqi construction sector. Traditional Iraqi clay bricks, shaped with various geometric patterns and perforations, were tested to improve their thermal performance and compare it to solid, non-perforated bricks. The experiments were conducted in a 1 × 1 × 2 m test chamber, insulated on all sides except the eastern side, where the test wall is located, which is exposed to external weather conditions and sunlight. An air conditioning unit was installed inside the test chamber to maintain the standard temperature during the tests. These perforated clay bricks, available in 25 and 35 mm diameters, demonstrated excellent thermal performance, reducing heat loads and minimizing the need for cooling during building renovations, thus lowering air conditioning energy consumption. These bricks exhibited the highest energy savings, resulting in an estimated 24 and 25% reduction, respectively, in thermal energy penetration into buildings. The thermal test of the highest energy-reducing bricks was conducted by sealing the 35 mm diameter holes with plastic plugs at both ends of each hole. This means that the air volume that filled the holes was reduced significantly, resulting in a 40% increase in energy reduction compared to solid bricks.
- Open Access
- 8 July 2026
- Published by Akademiai Kiado Zrt. in International Review of Applied Sciences and Engineering
- Vol. 17 (2) , 238-246
Optimum angle of using saw teeth roof instead of flat roof and reducing energy
Reducing heat gain, and thus cooling load, is a sustainability requirement. It contributes significantly to achieving sustainability by reducing energy consumption, reducing harmful emissions, and improving the environment. This can be achieved through effective thermal insulation, the use of sustainable building materials, and building designs that minimize heat loss. This research investigated the effect of building design through the changing of the roof design by converting a normal horizontal roof into multiple inclined roofs, as well as the effects to cooling loads. This study involved changing the roof slope to a saw tooth shaped wavy shape at various angles ranging from 0 to 60°, and for three different cases of the air gap generated in inclined roofs. The effect of coating the roof surface with ordinary paint and a reflective paint was also compared. The best results were achieved when the saw tooth shaped roof was inclined at an angle of 30° and in case (A), i.e., when the air gap was closed day and night. The annual cooling load value of the test room was 16.1 °C, less than in other cases. The highest value of percentage reduction in the cooling load was 9.1%. The value of annual cooling load at the ordinary surface was 83.4 Kw m −2 , but the value was 58.3 Kw m −2 , with the reflective surface. When exposed to direct sunlight, as is well known, the effect of direct sunlight far outweighs that of indirect sunlight. Consequently, the amount of heat transferred to the building decreases, reducing the operating time of air conditioning units. This, in turn, lowers the building's electricity consumption and results in savings in energy purchase costs. The optimal tilt angle for small roofs has been studied to maximize energy savings.
- 8 July 2026
- Published by Akademiai Kiado Zrt. in International Review of Applied Sciences and Engineering
- Vol. 17 (2) , 238-246
Open AccessOptimum angle of using saw teeth roof instead of flat roof and reducing energy
Reducing heat gain, and thus cooling load, is a sustainability requirement. It contributes significantly to achieving sustainability by reducing energy consumption, reducing harmful emissions, and improving the environment. This can be achieved through effective thermal insulation, the use of sustainable building materials, and building designs that minimize heat loss. This research investigated the effect of building design through the changing of the roof design by converting a normal horizontal roof into multiple inclined roofs, as well as the effects to cooling loads. This study involved changing the roof slope to a saw tooth shaped wavy shape at various angles ranging from 0 to 60°, and for three different cases of the air gap generated in inclined roofs. The effect of coating the roof surface with ordinary paint and a reflective paint was also compared. The best results were achieved when the saw tooth shaped roof was inclined at an angle of 30° and in case (A), i.e., when the air gap was closed day and night. The annual cooling load value of the test room was 16.1 °C, less than in other cases. The highest value of percentage reduction in the cooling load was 9.1%. The value of annual cooling load at the ordinary surface was 83.4 Kw m −2 , but the value was 58.3 Kw m −2 , with the reflective surface. When exposed to direct sunlight, as is well known, the effect of direct sunlight far outweighs that of indirect sunlight. Consequently, the amount of heat transferred to the building decreases, reducing the operating time of air conditioning units. This, in turn, lowers the building's electricity consumption and results in savings in energy purchase costs. The optimal tilt angle for small roofs has been studied to maximize energy savings.