OZOmer Adil Zainal

Omer Adil Zainal

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Omer Adil Zainal has a total of 21 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    An experimental study to improve wall thermal performance in Iraqi buildings utilizing several types of perforated bricks

    by Hadeel A. Hasan, Mahmood H. Khaleel, Aveen M. Abdulwahaab, Alaa Tariq Shukri, Omer Adil Zainal, Atif Ali Hasan

    Climate change, rising global surface temperatures, and global warming pose significant environmental and human challenges. These environmental changes negatively impact weather patterns and ambient temperatures, affecting the amount of heat transferred to buildings in summer and lost in winter. Maintaining standard indoor temperatures requires electricity consumption through air conditioning. Researchers are working to address these challenges to protect the environment and human health, reduce electricity consumption, and meet sustainability requirements in the Iraqi construction sector. Traditional Iraqi clay bricks, shaped with various geometric patterns and perforations, were tested to improve their thermal performance and compare it to solid, non-perforated bricks. The experiments were conducted in a 1 × 1 × 2 m test chamber, insulated on all sides except the eastern side, where the test wall is located, which is exposed to external weather conditions and sunlight. An air conditioning unit was installed inside the test chamber to maintain the standard temperature during the tests. These perforated clay bricks, available in 25 and 35 mm diameters, demonstrated excellent thermal performance, reducing heat loads and minimizing the need for cooling during building renovations, thus lowering air conditioning energy consumption. These bricks exhibited the highest energy savings, resulting in an estimated 24 and 25% reduction, respectively, in thermal energy penetration into buildings. The thermal test of the highest energy-reducing bricks was conducted by sealing the 35 mm diameter holes with plastic plugs at both ends of each hole. This means that the air volume that filled the holes was reduced significantly, resulting in a 40% increase in energy reduction compared to solid bricks.

  • Open Access

    Optimum angle of using saw teeth roof instead of flat roof and reducing energy

    by Aveen M. Abdulwahaab, Alaa T. Shukri, Hadeel A. Hasan, Omer A. Zainal, Atif A. Hasan

    Reducing heat gain, and thus cooling load, is a sustainability requirement. It contributes significantly to achieving sustainability by reducing energy consumption, reducing harmful emissions, and improving the environment. This can be achieved through effective thermal insulation, the use of sustainable building materials, and building designs that minimize heat loss. This research investigated the effect of building design through the changing of the roof design by converting a normal horizontal roof into multiple inclined roofs, as well as the effects to cooling loads. This study involved changing the roof slope to a saw tooth shaped wavy shape at various angles ranging from 0 to 60°, and for three different cases of the air gap generated in inclined roofs. The effect of coating the roof surface with ordinary paint and a reflective paint was also compared. The best results were achieved when the saw tooth shaped roof was inclined at an angle of 30° and in case (A), i.e., when the air gap was closed day and night. The annual cooling load value of the test room was 16.1 °C, less than in other cases. The highest value of percentage reduction in the cooling load was 9.1%. The value of annual cooling load at the ordinary surface was 83.4 Kw m −2 , but the value was 58.3 Kw m −2 , with the reflective surface. When exposed to direct sunlight, as is well known, the effect of direct sunlight far outweighs that of indirect sunlight. Consequently, the amount of heat transferred to the building decreases, reducing the operating time of air conditioning units. This, in turn, lowers the building's electricity consumption and results in savings in energy purchase costs. The optimal tilt angle for small roofs has been studied to maximize energy savings.

  • Thermal behavior of wall using balls of cementations sunflower seed husks powder

    by Omer Adil Zainal, Hadel Obaidi, Atif Ali Hasan, Alaa Tariq Shukri

    Due to the transfer of environmental heat into buildings, requires consuming large amounts of electrical energy for absorbed heat gain. This study used sunflower seed husks as one of the industrial residues, as a waste material. These husks were ground into a nano-powder and blended with cement at a weight of 1:5. From this mixture made of 12 mm diameter balls then added back to the building block mix during formation. The thermal behavior of the walls constructed from these blocks was tested in the climate of Baghdad, during daylight hours on the 21st day of each summer month (May – July) in 2022. The optimal addition ratio was 4%, which achieved a heat load of 176.2 kW and an electricity consumption of 110.2 kWh, resulting energy savings of 18.1% compared with a traditional wall.


  • Open Access

    Improving the building's thermal performance by using untraditional building blocks

    by H. Obaidi, Atif A. Hasan, Omer Adil Zainal Al‐Bayati, Mahmood H. Khaleel

    Iraqi buildings consume high-level electrical energy for air conditioning purposes to provide the standard human comfort condition. This paper adopted an experimental study by using Styrofoam adhesive or white cement as an alternative to ordinary Portland cement to manufacture building blocks with dimensions of 200 × 200 × 200 mm containing an internal core with dimensions of 90 × 130 × 130 mm, which were filled by using corrugated scratch-up or closed air gap. The samples were divided into two sets: the first had an aluminium foil layer applied to the external surface of the samples (reflective surface), while the second was without any layer (ordinary surface). The samples were tested under the climatic conditions of Baghdad city during the summer months (May to September) of 2021. These blocks were also evaluated by different structural tests. It can be seen from the test results that the use of Styrofoam adhesive with a reflective surface with panels of corrugated scratch-up increased the thermal insulation of the wall. It leads to reduce thermal leakage and the electrical energy consumed to provide comfortable thermal conditions by 52.7%, in addition to decreasing the mass density by 14.1% while compressive strength decreased by 21%.


  • Reducing Air‐Conditioning Load by Using an Insulating Material in Iraq as a Case Study (Experimental and Numerical)

    by Atif Ali Hasan, Omer Adil Zainal Al‐Bayati, Noor Samir Lafta, Mahmood H. Khaleel

    This paper has studied different types of walls using constant interior and exterior finishing materials (thermostone, 200‐mm thick (A); fired clay bricks, 240‐mm thick (B); hollow concrete blocks, 200‐mm thick (C); solid concrete blocks, 140‐mm thick (D); and limestone, 200‐mm thick (E)) due to the availability of many different types of building materials in Iraq and the lack of control over the best use to demonstrate how each of these materials affects a building's insulation to deliver the appropriate levels of comfort and achieve the greatest possible reduction in the electrical energy needed for air conditioning. A unique chamber was created for performing the actual trials on such walls in their natural environment, which was the climate of the city of Baghdad (zip code 10016, 33° N latitude, 44° E longitude). The tests have been done both in their current state of operation and with the addition of thermal insulation (60‐mm thick microfiber glass insulation material). The values for electricity consumption by a wall without insulation are 92, 121, 199, 148, and 138 kW/m2, in cases noted as A1, B1, C1, D1, and E1, respectively. However, when the insulator is used, the values become 58, 63, 51, 100, and 92 kW/m2 for the cases noted as A2, B2, C2, D2, and E2, respectively. The percentage reduction in electrical energy consumed by the air conditioner used within the room with and without thermal insulation has been recorded in the range of 50%–65% and 25%–60%, respectively. Depending on the model used, and compared with the traditional model, the saving difference with and without insulation was 15% and 35%, respectively. The best case is C2, because it has no effect on the room's interior area. Also, the cooling load was less than in other cases; it was 51 kW/m2 and had the highest building electrical savings, which are 65% when taking the wall in case C1 as a reference.

  • Open Access

    Reducing air-conditioning load by using an insulating material in Iraq as a case study (Experimental and Numerical)

    by Atif Ali Hasan, Omar Zainal, Noor Samir Lafta, Mahmood H Khaleel

    This topic has been studied using constant interior and exterior finishing materials (Thermostone, 200 mm thick (A), fired clay bricks, 240 mm thick (B), hollow concrete blocks, 200 mm thick (C), solid concrete blocks, 140 mm thick (D), and limestone, 200 mm thick (E)) due to the availability of many different types of building materials in Iraq and the lack of control over the use of the best. to demonstrate how each of these materials affects a building’s insulation to deliver the appropriate levels of comfort and achieve the greatest possible reduction in the electrical energy needed for air conditioning. A unique chamber was created for performing the actual trials on such walls in their natural environment, which was the climate of the city of Baghdad (zip code 10016,33 ºN latitude, 44 ° E longitude). And a unique room was created for performing real-world tests on those walls, either in their current state of operation or with the addition of thermal insulation (60 mm thick microfiber glass insulation materials). The values for electricity consumption are 199,138,121,101,92 kW/m2 without the insulator, but when the insulator is used, the values become 54,92,63,100,58 kw/m2 for the models Case-C1, Case-E1, Case-B1, Case-D1, and Case-A1. respectively, the percentage of the reduction in electrical energy consumed by the room’s air conditioner ranges from 25–60%, depending on the model compared to the conventional model, and the difference in savings is only 35%. The amount of savings in the electrical energy consumed by the air-conditioning unit used (to provide standard thermal conditions inside the building) will decrease when the insulator is incorporated into the structural components because the savings difference will be equal to 15% only when changing the quality of the wall used (described in the study) compared to the traditional method.

  • Experimental investigation of RTS method to calculate heat gain on walls and flat roof

    by Khalil Hassan Khalil, Merdin Danışmaz, Omer Adil Zainal Al-Bayati

    Multi-layered walls are commonly used building elements that have the potential to reduce cooling loads by improving thermal insulation. This paper investigates the potential of reducing cooling load using different types of multi-layered. For this purpose, a model of a small room (1.15 × 1 × 1 m) was constructed. A software code based on the radiant time series method was developed using MATLAB to extract heat gain results. The results were verified with other researchers, and there was a 0.89% error. Overall, the results show that using solid or hollow bricks in construction can be an effective way to reduce heat gain, where Wall-C achieved the minimum heat gain of 60.8 W m−2 compared to 66.207 and 71.225 W m−2 for Wall-A and Wall-B respectively. The reasons for this could be due to the insulation hollow area provided by the bricks, which tends to reduce heat transfer through the wall.


  • Open Access

    Thermal performance analysis of local building materials for energy efficiency in Iraq

    by Riyadh Husni Aljawad, Atif Ali Hasan, Mahmood Hussain Khaleel, Omer Adil Zainal

    Due to the harsh climate in summer of the Iraq, the outer shell of buildings is exposed to heat flow from the outside ambient to the inside building space, and causes increase of heat gain in the space, so it requires the using of air conditioning units, which is led to consume electrical energy to remove that heat gain. The objective of this paper to reduce levels of electrical consumption by choosing best building materials. The best building materials which are those have good resistance against heat flow, that’s why the cost of building material difference each of other in the local market. While Aso Company for Bricks is considered one of the largest modern companies producing building materials and the most present in the entire area of Iraq. The aim of this study to focus was on its products, and five types models were selected and compared with the traditional model that is still used now. Therefore, heat gain test was experimentally conducted in a test room located in Baghdad city (zip code 10016, latitude of 33.2°N and longitude of 44°E) for one day from 6 a.m. to 7 p.m. and for the 21st day of each of the summer months (May to September) in 2021. The electrical energy consumed by the air-conditioning unit in the test room was measured, and the researchers concluded that the percentage of energy savings achieved within the limits (13.88–1.2%) depending on the type and thickness of the building material. Results shown the best building material is (Type IV), these blocks can be used to create walls with a thickness of 200 mm or 100 mm. Building blocks (the fourth kind), on the other hand, have a delay time of 6:30 hours and a thermal shrinkage coefficient of 0.63. They also have a density of 919 kg/m3. Therefore, the electrical consumption by A.C. units if used the blocks (Type IV) less than others.


  • Reducing heat gain from sheet metal‐clad walls by utilizing industrially wasted materials (experimental study)

    by Mahmood H. Khaleel, Atif Ali Hasan, Omer Adil Zainal Al‐Bayati

    Buildings' walls are covered to reduce environmental impact and esthetics, and cladding materials vary based on public preference and financial capacity. Metal sheets with glossy surfaces are commonly used, but researchers propose using aluminum sheets and filling gaps with commercial waste materials, like, fabric roll sticks or circular plastic hollow parts. A test room with internal dimensions of 1 × 1 × 2 m used in Baghdad (latitude 33.2° N) was used to study thermal behavior, with a window‐type air conditioner providing standard thermal conditions. The air gap attached to the top of the test wall was either left open or closed during the day. Results showed that double‐layer bamboo packing preserved 52.1% with a closed‐air gap and 49.5% with an open‐air gap, but no discernible difference was observed between the two situations.