SDSerik Didar

Serik Didar

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Serik Didar has a total of 23 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    State-of-the-Art Knee Exoskeleton for Gait Assistance and Rehabilitation: Systematic Review

    by Dilnoza Karibzhanova, Aibek Niyetkaliyev, Amna R Khawaja, Aray Zhaisanbek, Zeeshan, Ardana Utepbergen, Prashant K Jamwal, Kassymbek Ozhikenov, Aiman Ozhikenova, Chingiz Alimbayev, et al.

    Background: Knee exoskeletons represent a significant advancement in wearable robotic technology, developed to enhance gait assistance and facilitate rehabilitation processes. These devices are increasingly used in clinical and research environments worldwide. Nonetheless, the existing empirical evidence supporting their biomechanical and functional outcomes lacks both breadth and clarity. Further investigation is essential to elucidate the specific effects of knee exoskeletons on gait dynamics and rehabilitation efficacy. Objective: This study aims to systematically review the clinical and biomechanical evidence on knee exoskeletons used for gait assistance and rehabilitation. Methods: A systematic search of databases—PubMed, Web of Science, IEEE Xplore, and Scopus—was conducted to identify eligible studies published between January 2015 and March 2025. Studies were included if they investigated knee exoskeleton systems in human participants for gait assistance and rehabilitation. Randomized controlled trials, observational studies, and experimental investigations were eligible. Exclusion criteria were multijoint exoskeletons, nonhuman studies, and simulation-based analyses. Two reviewers independently extracted study characteristics, participant demographics, device features, intervention protocols, and clinical and biomechanical outcomes. Risk of bias was assessed using RoB-2 (Cochrane Risk of Bias 2) for randomized controlled trials and ROBINS-I (Risk of Bias in Nonrandomized Studies of Interventions) for nonrandomized studies. Results: Thirty-two studies met the inclusion criteria. Most investigations involved healthy adults in feasibility or pilot settings, while a smaller subset included individuals with stroke, spinal cord injury, or orthopedic conditions or pediatric movement disorders. Across studies, knee exoskeletons demonstrated short-term improvements in spatiotemporal gait parameters, including increased gait speed and step length, improved knee joint kinematics, and reductions in muscular effort or metabolic demand. However, substantial heterogeneity in device design, outcome metrics, and intervention duration limits comparability across studies. Sample sizes were typically small, and follow-up outcomes were rarely reported, restricting the interpretation of the long-term clinical efficacy of these devices. Conclusions: Knee exoskeletons demonstrate promising short-term functional and biomechanical benefits and are increasingly feasible within structured rehabilitation settings. While current evidence is limited by small sample sizes and brief follow-up periods, emerging data suggest potential for enhancing task-specific gait training. Larger, well-designed trials are needed to determine sustained clinical impact and integration into routine rehabilitation practice.

  • Open Access

    Development of a Material Database and an Automated Selection Algorithm for a Surgical Robotic Manipulator

    by Dinara Bolatbekova, Didar Serik, Ukilay Beisenali, Chingiz Alimbayev, Zhadyra Alimbayeva, Kassymbek Ozhikenov

    Material selection for surgical robotic manipulators remains a challenging engineering problem because candidate materials must simultaneously satisfy mechanical, biomedical, environmental, manufacturing, and economic requirements. This challenge is particularly important in robotic systems for knee arthroplasty, where structural reliability and positioning accuracy strongly depend on material properties. This study presents the development of a structured component-oriented material database and an automated material selection algorithm for a collaborative surgical manipulator intended for knee joint endoprosthesis procedures. The database includes metallic materials, engineering polymers, composites, and ceramics together with their mechanical, environmental, biomedical, manufacturing, and economic characteristics. Based on this database, a multi-stage decision-support framework was developed that integrates component-specific material retrieval, hard-constraint filtering, criterion normalization, adaptive weighting, TOPSIS-based ranking, and post-ranking feasibility verification. Unlike conventional approaches that evaluate all materials simultaneously, the proposed framework retrieves only materials relevant to the selected manipulator component, reducing the search space and improving decision consistency. A numerical case study was performed for the load-bearing structure. The algorithm retrieved 21 candidate materials with complete data, of which 6 satisfied the mandatory engineering and biomedical constraints. These materials were subsequently ranked using the TOPSIS method, with AISI 316 identified as the most suitable material because of its balanced combination of mechanical strength, corrosion resistance, sterilization compatibility, and durability. Comparative evaluation using the SAW method produced the same three highest-ranked materials, while sensitivity analysis demonstrated that the ranking remained stable under moderate variations in weighting coefficients. The proposed framework provides a transparent, reproducible, and practically applicable approach to material selection for surgical robotic manipulators and establishes a foundation for future integration with CAD/CAE environments, intelligent decision-support systems, and machine-learning-assisted engineering design.

  • Open Access

    State-of-the-art Knee Exoskeleton for gait assistance and rehabilitation: Systematic Review (Preprint)

    by Dilnoza Karibzhanova, Aibek Niyetkaliyev, Amna R. Khawaja, Aray Zhaisanbek, Zeeshan, Ardana Utepbergen, Prashant K. Jamwal, Kassymbek Ozhikenov, Aiman Ozhikenova, Chingiz Alimbayev, et al.

    BACKGROUND Knee exoskeletons represent a significant advancement in wearable robotic technology, developed to enhance gait assistance and facilitate rehabilitation processes. These devices are increasingly employed in clinical and research environments worldwide. Nonetheless, the existing empirical evidence that substantiates their biomechanical and functional outcomes lacks comprehensive breadth and clarity. Further investigation is essential to elucidate the specific effects of knee exoskeletons on gait dynamics and rehabilitation efficacy. OBJECTIVE To systematically review the clinical and biomechanical evidence on knee exoskeletons used for gait assistance and rehabilitation. METHODS A systematic search of databases including PubMed, Web of Science, IEEE Xplore, and Scopus was conducted to identify eligible studies published between January 2015 and March 2025. Studies were included if they investigated knee exoskeleton systems in human participants for gait assistance and rehabilitation. Randomized Controlled Trials, Observational studies, and Experimental investigations were eligible. Exclusion criteria were multi-joint exoskeletons, non-human studies, and simulation-based analyses. Two reviewers independently extracted study characteristics, participant demographics, device features, intervention protocols, and clinical and biomechanical outcomes. Risk of bias was assessed using RoB-2 for randomized controlled trials and ROBINS-I for non-randomized studies. RESULTS Thirty-two studies met the inclusion criteria. Most investigations involved healthy adults in feasibility or pilot settings, while a smaller subset included individuals with stroke, spinal cord injury, or orthopedic conditions or pediatric movement disorders. Across studies, knee exoskeletons demonstrated short-term improvements in spatiotemporal gait parameters, knee joint kinematics, and metabolic efficiency. However, substantial heterogeneity in device design, outcome metrics, and intervention duration leads to limited comparability across studies. Sample sizes were typically small, and follow-up outcomes were rarely reported, restricting the interpretation of the long-term clinical efficacy of these devices. CONCLUSIONS Knee exoskeletons demonstrate promising short-term functional and biomechanical benefits and are increasingly feasible within structured rehabilitation settings. While current evidence is limited by small sample sizes and brief follow-up, emerging data suggests the potential to enhance task-specific gait training. Larger, well-designed trials are needed to determine sustained clinical impact and integration into routine rehabilitation practice. CLINICALTRIAL This systematic review was registered in PROSPERO (CRD420261285256)

  • Open Access

    Kinematic Performance Assessment of a Cable-Driven Elbow–Wrist Exoskeleton for Upper Limb Rehabilitation

    by Sharafatdin Yesirkepov, Adilet Toleshev, Shylmyrza Ussen, Igembay Yerbolat, Serik Didar, Murat Alibek, Есиркепов Ш., Үсен Ш., Серік Д.

    The aim: To evaluate the kinematic performance of a cable-driven elbow-wrist exoskeleton intended for upper limb rehabilitation in orthopaedic and post-traumatic conditions. Methods. A four-degree-of-freedom cable-driven exoskeleton was designed to assist elbow flexion-extension and multi-axis wrist motion. To reduce distal inertia and minimize joint misalignment commonly associated with rigid transmission systems, a cable-based actuation architecture was implemented. The elbow mechanism was configured as a single-degree-of-freedom joint powered by two antagonistic motors enabling bidirectional torque generation and modulation of joint stiffness through co-contraction principles. The wrist module provided three rotational degrees of freedom actuated by four tendons, where three cables-controlled roll and pitch motions and a diagonally oriented cable enabled yaw rotation. Kinematic modeling was performed using homogeneous transformation matrices to establish forward and inverse kinematic relationships from the proximal fixation point to the distal platform. Numerical simulations were conducted in MATLAB, followed by experimental validation on a scaled prototype. Cable displacement responses were compared with theoretical inverse kinematic predictions throughout the operational workspace. Results. The developed system demonstrated consistent agreement between theoretical modeling and experimental measurements. The elbow module achieved controlled flexion and extension within a range from minus sixty to sixty degrees, with stable bidirectional motion and predictable cable displacement patterns. The wrist mechanism preserved smooth multi-axis rotation and maintained mechanical transparency across roll, pitch, and yaw movements without evidence of kinematic singularities within the tested workspace. Experimental results confirmed accurate mapping between joint angles and cable actuation lengths, supporting the validity of the proposed kinematic model. Conclusion. The proposed cable-driven elbow–wrist exoskeleton demonstrates reliable kinematic performance and reduced mechanical inertia compared to rigid transmission systems. The validated modeling framework establishes a foundation for the future implementation of hybrid position and torque control strategies in orthopaedic upper limb rehabilitation technologies.