Claudia Grotteria
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Claudia Grotteria has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Filippo Pepe
Department of Orthodontics, University of Ferrara, Ferrara, Italy
1 shared publication - Francesca Cremonini
Postgraduate School of Orthodontics, University of Ferrara, Via Luigi Borsari 46, 44121 Ferrara, Italy
1 shared publication - Giuliano Bortolo Maino
Postgraduate School of Orthodontics, University of Ferrara, Ferrara, Italy
1 shared publication - Luca Brucculeri
Department of Orthodontics, University of Ferrara, Ferrara, Italy
1 shared publication - Luca Lombardo
Postgraduate School of Orthodontics, University of Ferrara, 44121 Ferrara, Italy
1 shared publication - Mario Palone
Department of Orthodontics, University of Ferrara, Ferrara, Italy
1 shared publication
Latest Publications
- Open Access
- 3 March 2026
- Published by Springer Nature in Journal of Orofacial Orthopedics / Fortschritte der Kieferorthopädie
- p. 1-16
Factors influencing the accuracy of guided palatal miniscrew insertion in young adults
Objective: To evaluate the in vivo accuracy of guided palatal miniscrew insertion, focusing on the effect of insertion side, frontal insertion angle, and miniscrew length. Materials and methods: In all, 52 palatal miniscrews were inserted using computer-aided design/computer-aided manufacturing (CAD/CAM) surgical guides in 20 patients (average age: 19.74 years ± 6.83). Digital models were acquired after miniscrew insertion and scanbody application. Then, linear and angular discrepancies between planned and realized miniscrew positions were evaluated by superimposing the reference model with the final postinsertion model. Discrepancies are recorded and compared to absolute precision (hypothetical). The effect of side, frontal insertion angle, and miniscrew length on accuracy were investigated. Results: Mean linear total discrepancies were 1.10 ± 1.01 mm and 1.71 ± 1.10 mm at the miniscrew head and tip points, respectively. Mean angular discrepancies were 5.90 ± 6.06° in the transverse (XY), 2.65 ± 2.47° in the sagittal (YZ), and 3.02 ± 2.65° in the coronal (XZ) plane. All discrepancies were significantly different to absolute precision ( p < 0.001), although not to an extent considered clinically relevant. Neither side nor frontal insertion angle (clinical factors), or miniscrew length (structural factor) significantly impacted accuracy. Conclusion: CAD/CAM surgical guides ensured clinically acceptable accuracy despite significant deviations from absolute precision. The insertion side, frontal insertion angle, and miniscrew length had minimal influence on accuracy, and therefore on outcome. Further studies should explore the effects of additional clinical, procedural, anatomical, and structural variables.
- 3 March 2026
- Published by Springer Nature in Journal of Orofacial Orthopedics / Fortschritte der Kieferorthopädie
- p. 1-16
Open AccessFactors influencing the accuracy of guided palatal miniscrew insertion in young adults
Objective: To evaluate the in vivo accuracy of guided palatal miniscrew insertion, focusing on the effect of insertion side, frontal insertion angle, and miniscrew length. Materials and methods: In all, 52 palatal miniscrews were inserted using computer-aided design/computer-aided manufacturing (CAD/CAM) surgical guides in 20 patients (average age: 19.74 years ± 6.83). Digital models were acquired after miniscrew insertion and scanbody application. Then, linear and angular discrepancies between planned and realized miniscrew positions were evaluated by superimposing the reference model with the final postinsertion model. Discrepancies are recorded and compared to absolute precision (hypothetical). The effect of side, frontal insertion angle, and miniscrew length on accuracy were investigated. Results: Mean linear total discrepancies were 1.10 ± 1.01 mm and 1.71 ± 1.10 mm at the miniscrew head and tip points, respectively. Mean angular discrepancies were 5.90 ± 6.06° in the transverse (XY), 2.65 ± 2.47° in the sagittal (YZ), and 3.02 ± 2.65° in the coronal (XZ) plane. All discrepancies were significantly different to absolute precision ( p < 0.001), although not to an extent considered clinically relevant. Neither side nor frontal insertion angle (clinical factors), or miniscrew length (structural factor) significantly impacted accuracy. Conclusion: CAD/CAM surgical guides ensured clinically acceptable accuracy despite significant deviations from absolute precision. The insertion side, frontal insertion angle, and miniscrew length had minimal influence on accuracy, and therefore on outcome. Further studies should explore the effects of additional clinical, procedural, anatomical, and structural variables.