BLBoxiang Liu

Boxiang Liu

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Boxiang Liu has a total of 6 co-authors. Here are the top co-authors by number of shared publications:

  • Jiaxuan Che

    Hebei Key Laboratory of Low Carbon and High Efficiency Power Generation Technology, North China Electric Power University, Baoding 071003, China

    1 shared publication
  • Junbang Yao

    Hebei Key Laboratory of Low Carbon and High Efficiency Power Generation Technology, North China Electric Power University, Baoding 071003, China

    1 shared publication
  • Tao Yang

    School of Mechanical Engineering, Beijing Institute of Technology, Beijing 100081, China

    1 shared publication
  • Xiaojing Li

    Hebei Key Laboratory of Low Carbon and High Efficiency Power Generation Technology, North China Electric Power University, Baoding 071003, China

    1 shared publication
  • Xing Liu

    Xi’an Xiatech Electronics Co., Ltd., Xi’an 710054, China

    1 shared publication
  • Yaxin Zhang

    Hebei Key Laboratory of Low Carbon and High Efficiency Power Generation Technology, North China Electric Power University, Baoding 071003, China

    1 shared publication

Latest Publications

  • Open Access

    Numerical Simulation and Experimental Research of the Hot-Wire Method for Thermal Insulation Materials

    by Jiaxuan Che, Yaxin Zhang, Junbang Yao, Xiaojing Li, Xing Liu, Boxiang Liu, Tao Yang

    The thermal conductivity of thermal insulation materials is a critical parameter for assessing energy efficiency and performance in building, industrial, and aerospace applications. This study combined numerical simulation, parameter inversion optimization and experimental measurement to evaluate the transient hot-wire method for measuring the thermal conductivity of expanded polystyrene (EPS) foam. Using a nickel wire as the hot wire, the effects of various parameters—including wire length and width, heating power, Kapton film thickness and end effect—were systematically analyzed through finite element analysis and Bayesian optimization algorithm. Following the simulation and inversion conclusions, a series of hot-wire sensors with a fixed length of 30 mm and widths of 25 μm, 50 μm, 100 μm, 150 μm, and 200 μm were fabricated for experimental validation. Measurement results were compared against a reference value obtained by the guarded hot plate method. It was found that the sensor with a length of 30 mm and a width of 100 μm demonstrated optimal performance among the configurations tested, with deviations between the experimental measurements and the reference value remaining within approximately ±1.5%.