Douglas Reindl
Research Subjects
Research Interests
Douglas Reindl has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
Gregory Nellis
2 shared publicationsAusten Fradeneck
1 shared publication- Brett Andrew Prussack
Department of Mechanical Engineering, University of Wisconsin–Madison, 1513 University Ave., Madison, WI 53706
1 shared publication - Eric Alar
Univ Wisconsin, Dept Mech Engn, 1513 Univ Ave, Madison, WI 53706 USA
1 shared publication Erik Pagenkopf
1 shared publication- Ian Jentz
University of Wisconsin-Madison, Madison, WI
1 shared publication
Latest Publications
- Open Access
- 23 June 2026
- Published by Elsevier in SSRN Electronic Journal
Edge Effects on the Pressure Drop Through Triply Periodic Minimal Surface Heat Exchangers
Triply periodic minimal surface (TPMS) geometries offer significant potential for compact, high-performance heat exchangers, but the influence of cross-sectional confinement on pressure drop of small-scale TPMS test articles remains unquantified. Truncation of the periodic structure introduces wall-induced edge effects that can substantially distort measured pressure drop and flow uniformity, compromising the extrapolation of sub-scale experimental data to full-scale heat exchanger performance.This study presents the first systematic isolation of the cross-sectional unit cell count effect on Diamond TPMS pressure drop under physical no-slip boundary conditions, combining experimental measurements (1×1 through 6×6 configurations, Re = 125–7500), CFD simulations (Re up to 8000), flow field visualization, and region-resolved hydrodynamic analysis. A curve fit is developed that collapses the per-unit-length pressure drop ratio across the Re = 3000–8000 range into a single equation, enabling direct estimation of the confinement penalty and extrapolation to the infinite-lattice asymptote for the studied geometry. CFD predictions agree with experimental measurements to within a mean absolute error of 9% for the 1×1 through 3×3 configurations and within 15% across the full 1×1 through 6×6 range.Preliminary testing on alternative Diamond TPMS configurations confirmed that the qualitative mechanisms responsible for edge effects extend beyond the specific geometry studied here, though the quantitative magnitude of the confinement penalty is geometry-dependent. Flow field visualization and region-resolved analysis identify the underlying physical mechanisms: corner recirculation in dead-end pockets of rearward-facing lattice peaks and high-velocity channeling through diagonally opposing forward-facing corners produce a previously uncharacterized spatial asymmetry that scales predictably with cross-sectional size. These findings deliver a geometry-specific scaling law for the 75D Diamond TPMS and a transferable mechanistic framework for interpreting sub-scale TPMS test data in nuclear, aerospace, and high-power-density thermal management applications.
- 23 June 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessEdge Effects on the Pressure Drop Through Triply Periodic Minimal Surface Heat Exchangers
Triply periodic minimal surface (TPMS) geometries offer significant potential for compact, high-performance heat exchangers, but the influence of cross-sectional confinement on pressure drop of small-scale TPMS test articles remains unquantified. Truncation of the periodic structure introduces wall-induced edge effects that can substantially distort measured pressure drop and flow uniformity, compromising the extrapolation of sub-scale experimental data to full-scale heat exchanger performance.This study presents the first systematic isolation of the cross-sectional unit cell count effect on Diamond TPMS pressure drop under physical no-slip boundary conditions, combining experimental measurements (1×1 through 6×6 configurations, Re = 125–7500), CFD simulations (Re up to 8000), flow field visualization, and region-resolved hydrodynamic analysis. A curve fit is developed that collapses the per-unit-length pressure drop ratio across the Re = 3000–8000 range into a single equation, enabling direct estimation of the confinement penalty and extrapolation to the infinite-lattice asymptote for the studied geometry. CFD predictions agree with experimental measurements to within a mean absolute error of 9% for the 1×1 through 3×3 configurations and within 15% across the full 1×1 through 6×6 range.Preliminary testing on alternative Diamond TPMS configurations confirmed that the qualitative mechanisms responsible for edge effects extend beyond the specific geometry studied here, though the quantitative magnitude of the confinement penalty is geometry-dependent. Flow field visualization and region-resolved analysis identify the underlying physical mechanisms: corner recirculation in dead-end pockets of rearward-facing lattice peaks and high-velocity channeling through diagonally opposing forward-facing corners produce a previously uncharacterized spatial asymmetry that scales predictably with cross-sectional size. These findings deliver a geometry-specific scaling law for the 75D Diamond TPMS and a transferable mechanistic framework for interpreting sub-scale TPMS test data in nuclear, aerospace, and high-power-density thermal management applications.