Junsik Choi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Junsik Choi has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
Eunchong Park
Sungkyunkwan University (SKKU)
1 shared publication- Heeyeop Chae
School of Chemical Engineering, Sungkyunkwan University (SKKU), Suwon 16419, Republic of Korea
1 shared publication Hyeonjin Choi
Sungkyunkwan University (SKKU)
1 shared publicationIn-Joong Kim
Memory Etch Technology Team, Samsung Electronics
1 shared publicationJaehyeon Kim
Sungkyunkwan University (SKKU)
1 shared publicationSanghee Han
Sungkyunkwan University (SKKU)
1 shared publication
Latest Publications
- 19 March 2026
- Published by Optica Publishing Group in Optics Express
- Vol. 34 (6) , 11382
Optical emission spectral analysis using FastICA for diagnosing wafer edge uniformity in plasma etching
Spatially integrated signals in optical emission spectroscopy (OES) inherently mask localized reaction dynamics at the wafer edge. This study applies independent component analysis (ICA) to standard plasma emission spectra to resolve this spatial limitation without hardware modification. The FastICA algorithm decouples edge-specific transient dynamics from the bulk plasma background. Subsequently, second-order temporal derivative analytics isolate the distinct oscillatory signature induced by the edge-localized impedance mismatch. Analysis reveals that a characteristic intensity modulation of argon emission lines correlates with transient shifts in the electron energy distribution function (EEDF). The predictive model, validated via leave-one-out cross-validation (LOOCV), achieves a cross-validated coefficient of determination Q 2 of 0.913. These results demonstrate that the proposed method provides a highly reliable and robust computational alternative to dedicated spatial sensors for diagnosing wafer edge uniformity. This computational framework transforms a standard 1D optical sensor into a spatially resolvable diagnostic tool.
- 19 March 2026
- Published by Optica Publishing Group in Optics Express
- Vol. 34 (6) , 11382
Optical emission spectral analysis using FastICA for diagnosing wafer edge uniformity in plasma etching
Spatially integrated signals in optical emission spectroscopy (OES) inherently mask localized reaction dynamics at the wafer edge. This study applies independent component analysis (ICA) to standard plasma emission spectra to resolve this spatial limitation without hardware modification. The FastICA algorithm decouples edge-specific transient dynamics from the bulk plasma background. Subsequently, second-order temporal derivative analytics isolate the distinct oscillatory signature induced by the edge-localized impedance mismatch. Analysis reveals that a characteristic intensity modulation of argon emission lines correlates with transient shifts in the electron energy distribution function (EEDF). The predictive model, validated via leave-one-out cross-validation (LOOCV), achieves a cross-validated coefficient of determination Q 2 of 0.913. These results demonstrate that the proposed method provides a highly reliable and robust computational alternative to dedicated spatial sensors for diagnosing wafer edge uniformity. This computational framework transforms a standard 1D optical sensor into a spatially resolvable diagnostic tool.