Xi Zuo
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Xi Zuo has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Hongliang Wang
State Key Laboratory of Extreme Environment Optoelectronic Dynamic Measurement Technology and Instrument, North University of China, Taiyuan, China
2 shared publications - Rui Ren
State Key Laboratory of Extreme Environment Optoelectronic Dynamic Measurement Technology and Instrument, North University of China, Taiyuan, China
2 shared publications - Wendong Zhang
North University of China
2 shared publications - Changang Chen
State Key Laboratory of Extreme Environment Optoelectronic Dynamic Measurement Technology and Instrument, North University of China, Taiyuan, China
1 shared publication - Changde He
State Key Laboratory of Extreme Environment Optoelectronic Dynamic Measurement Technology and Instrument, North University of China, Taiyuan 030051, China
1 shared publication - Dan Gao
State Key Laboratory of Extreme Environment Optoelectronic Dynamic Measurement Technology and Instrument, North University of China, Taiyuan, China
1 shared publication
Latest Publications
- 26 March 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 75 (00189456) , 1-18
Rapid High-Resolution Breast Imaging With Ring-Array Multi-Subarray Synthetic-Aperture Frequency-Domain Ultrasound Computed Tomography Method
Ultrasound computed tomography (USCT) using ring array technology has shown great potential in breast diagnosis. This study addresses the problems of low imaging resolution and long acquisition time in USCT for breast diagnosis by proposing a frequency domain imaging method based on a ring array and multi-subarray synthetic aperture. This method achieves omnidirectional transmission and reception through beam focusing synthesis, enabling tomographic scanning, supporting complete 3D CT reconstruction, and simulating the performance of a large-aperture system with a small array, achieving sub-millimeter-level imaging resolution. By combining a frequency delay-compensated beamforming method and a designed adjustment strategy, effective signal components are filtered from the large amount of data received by the ring array, completing lossless signal conversion between the time and frequency domains, reducing the reconstruction time to less than 6 seconds, a 7.4-fold improvement over traditional time-domain methods and approximately 2.6 times faster than existing clinical breast CT systems. Experiments show that The breast tissue membrane reconstruction demonstrates high fidelity, and Preliminary clinical pilot study and MRI results are trend-level agreement in boundary, and spatial distribution, validating the effectiveness and accuracy of this method in clinical practice.
- 26 March 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 75 (00189456) , 1-18
Rapid High-Resolution Breast Imaging With Ring-Array Multi-Subarray Synthetic-Aperture Frequency-Domain Ultrasound Computed Tomography Method
Ultrasound computed tomography (USCT) using ring array technology has shown great potential in breast diagnosis. This study addresses the problems of low imaging resolution and long acquisition time in USCT for breast diagnosis by proposing a frequency domain imaging method based on a ring array and multi-subarray synthetic aperture. This method achieves omnidirectional transmission and reception through beam focusing synthesis, enabling tomographic scanning, supporting complete 3D CT reconstruction, and simulating the performance of a large-aperture system with a small array, achieving sub-millimeter-level imaging resolution. By combining a frequency delay-compensated beamforming method and a designed adjustment strategy, effective signal components are filtered from the large amount of data received by the ring array, completing lossless signal conversion between the time and frequency domains, reducing the reconstruction time to less than 6 seconds, a 7.4-fold improvement over traditional time-domain methods and approximately 2.6 times faster than existing clinical breast CT systems. Experiments show that The breast tissue membrane reconstruction demonstrates high fidelity, and Preliminary clinical pilot study and MRI results are trend-level agreement in boundary, and spatial distribution, validating the effectiveness and accuracy of this method in clinical practice.
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 26 (16) , 1
A CMUT-Based Dual-mode Sensor with Wide Range and High Sensitivity for Absolute Pressure Measurement
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 26 (16) , 1
A CMUT-Based Dual-mode Sensor with Wide Range and High Sensitivity for Absolute Pressure Measurement