MSM. S. Squillante

M. S. Squillante

*This is an algorithmically generated author record based on publicly available information.

M. S. Squillante has a total of 17 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Imaging Results From a Direct Conversion X-Ray Detector With TlBr and CMOS Pixel Array

    by J. F. Christian, M. S. Squillante, M. J. Breen, O. Maksimov, H. Kim, E. Weststrate, A. Kargar, V. Nagarkar, M. Dallimore, A. Pil-Ali, et al.

    This work explores the fabrication and characterization of X-ray imaging devices using a single-crystal TlBr sample (8 mm × 8 mm × 10 mm) and polycrystalline TlBr film (approximately 0.38-mm thick), both bonded to a Libra-1 Complementary Metal-Oxide-Semiconductor (CMOS) readout chip connected to the BrillianSe 1M readout system. The BrillianSe 1M, designed for X-ray radiography by KA Imaging, features a 10 mm × 11 mm readout chip with a 7.8 μm pixel pitch and a 7.8 mm × 7.8 mm active area. The work below describes the characterization of test and imaging devices. The characterization includes current-voltage (IV) curves and impedance spectra, longevity measurements of the X-ray response and leakage current, and imaging characterization with light-emitting diodes (LED) and X-rays. The resistivity of 3x1010 Ω-cm was estimated for a polycrystalline film sample. Following five weeks, the leakage current decreased from 670 to 6.4 nA, while the X-ray photocurrent decreased from 28 to 4 nA. Both the single crystal and polycrystalline imaging devices resolved 0.3-mm-diameter holes in a Tungsten composite mask when irradiated with 90 kVp (100 μA tube current) X-rays. Effects at the interface can be seen with both LED and X-rays. The images provide critical information for optimizing the fabrication process and device longevity.

  • TlBr Films for Direct Digital Radiography

    by M. S. Squillante, M. J. Breen, J. F. Christian, A. Kargar, Y. Ogorodnik, F. Robertson, V. Nagarkar, M. R. Squillante, L. Cirignano, O. Maksimov, et al.

    The detector that converts X-ray intensity into a digitized electronic signal, processed into an image, often limits the performance of modern X-ray imaging systems, whether for medical, research, or industrial applications. Digital radiography (DR) uses the following two types of detectors: 1) indirect detectors, where a scintillating film converts X-rays into an optical signal read by an optical detector, and 2) direct detectors using semiconductors. Semiconductor X-ray detector technology typically uses a silicon wafer, an amorphous selenium (a-Se) film, or a relatively thin cadmium zinc telluride (CZT) crystal bump bonded to a readout platform. Although the use of a-Se and CZT improves the attenuation coefficient beyond that of silicon, a further increase in performance is highly desirable for improved imaging of higher-energy X-rays (greater than 20 keV). This article presents results on thallium bromide (TlBr) films coupled to a read-out integrated circuit (ROIC). TlBr, an attractive material for hard X-ray imaging due to its high atomic number and high density, achieves an image resolution of $20 \mu $ m as a 1 cm ${}^{2} \times 100$ - $\mu $ m-thick columnar film deposited on CMOS ROIC.