Arif Harjanto
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Arif Harjanto has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Happy Nugroho
Universitas Mulawarman
2 shared publications - Adi Pandu Wirawan
Universitas Mulawarman
1 shared publication - Aji Ery Burhandenny
Mulawarman University
1 shared publication - Aprilia Amrina Ainurrosyidah
Universitas Mulawarman
1 shared publication Bayu Ramadhani
Universitas Mulawarman
1 shared publicationFalah Hadaya Tauladan
Universitas Mulawarman
1 shared publication
Latest Publications
- Open Access
- 2 November 2026
- Published by Universitas Malikussaleh in International Journal of Engineering, Science and Information Technology
- Vol. 6 (4) , 74-84
Design and Construction of a 72V 20Ah Lithium-Ion BMS-Integrated Electric Vehicle Battery Pack for the Pesut EV.1 Electric Go-Kart
This research aims to design, build, and test a 72 Volt 20 Ah lithium-ion battery pack for the Pesut EV.1 Mahakam Team electric go-kart. The battery pack is designed with a 20S4P configuration using lithium-ion cells, equipped with a Daly 72 Volt 100 Ampere Battery Management System (BMS), and modeled in CAD software. Testing was carried out through three charging and discharging trials to analyze the voltage, current, and temperature parameters during the process. To enable real-time monitoring, visualization, and data logging during go-kart operation, an IoT-based telemetry system was integrated using a microcontroller and dedicated sensors communicating via the MQTT protocol. In addition, thermal simulations were carried out using FEA software. The test results demonstrated stable and consistent battery performance. During the charging process, the voltage gradually increased from 68 V to 84 V with a stable charging current in the range of 5.90 A – 12.37 A, yielding an average absorbed capacity of 21.15 Ah and input energy of 1,612.11 Wh, while the temperature remained between 25.00 °C and 28.50 °C. Meanwhile, during the discharging process, the voltage gradually decreased from 84 V to approximately 68 V, with the discharge current reaching up to 68.7 A and a maximum temperature of 43 °C. However, dynamic discharge capacity calculation using a 30-second logging interval resulted in overestimation errors due to transient current fluctuations, indicating the need for higher sampling frequencies in future evaluations. Simulation results also demonstrated an even temperature distribution and no overheating during operation. The results indicate that the developed battery pack performed reliably under the tested charging and discharging conditions for Pesut EV.1 Electric Go-Kart usage and racing applications.
- 2 November 2026
- Published by Universitas Malikussaleh in International Journal of Engineering, Science and Information Technology
- Vol. 6 (4) , 74-84
Open AccessDesign and Construction of a 72V 20Ah Lithium-Ion BMS-Integrated Electric Vehicle Battery Pack for the Pesut EV.1 Electric Go-Kart
This research aims to design, build, and test a 72 Volt 20 Ah lithium-ion battery pack for the Pesut EV.1 Mahakam Team electric go-kart. The battery pack is designed with a 20S4P configuration using lithium-ion cells, equipped with a Daly 72 Volt 100 Ampere Battery Management System (BMS), and modeled in CAD software. Testing was carried out through three charging and discharging trials to analyze the voltage, current, and temperature parameters during the process. To enable real-time monitoring, visualization, and data logging during go-kart operation, an IoT-based telemetry system was integrated using a microcontroller and dedicated sensors communicating via the MQTT protocol. In addition, thermal simulations were carried out using FEA software. The test results demonstrated stable and consistent battery performance. During the charging process, the voltage gradually increased from 68 V to 84 V with a stable charging current in the range of 5.90 A – 12.37 A, yielding an average absorbed capacity of 21.15 Ah and input energy of 1,612.11 Wh, while the temperature remained between 25.00 °C and 28.50 °C. Meanwhile, during the discharging process, the voltage gradually decreased from 84 V to approximately 68 V, with the discharge current reaching up to 68.7 A and a maximum temperature of 43 °C. However, dynamic discharge capacity calculation using a 30-second logging interval resulted in overestimation errors due to transient current fluctuations, indicating the need for higher sampling frequencies in future evaluations. Simulation results also demonstrated an even temperature distribution and no overheating during operation. The results indicate that the developed battery pack performed reliably under the tested charging and discharging conditions for Pesut EV.1 Electric Go-Kart usage and racing applications.
- Open Access
- 17 January 2026
- Published by Universitas Malikussaleh in International Journal of Engineering, Science and Information Technology
- Vol. 6 (1) , 36-43
Improving TDS Sensor Accuracy in an IoT-Based Fertigation Prototype Using Polynomial Regression Calibration and Interpolation
Accurate measurement of Total Dissolved Solids (TDS) is a critical requirement for hydroponic nutrient management, especially in automated fertigation systems that adjust nutrient concentrations based on plant age. However, non-industrial TDS sensors often exhibit significant fluctuations and non-linear errors, leading to unreliable nutrient dosing. This study proposes a calibration approach using second-order polynomial regression combined with interpolation to improve the accuracy of TDS measurements in an IoT-based fertigation prototype for lettuce hydroponics. The calibration was performed using reference TDS solutions and a digital TDS meter to ensure accurate measurements. The results show that the Mean Absolute Percentage Error (MAPE) decreased from 24.771% to 7.5768% during calibration, demonstrating a significant improvement in measurement accuracy. The calibrated sensor readings fall within the acceptable range for hydroponic nutrient control (±10%). This method provides a low-cost, reliable alternative for improving sensor accuracy in IoT fertigation systems.
- 17 January 2026
- Published by Universitas Malikussaleh in International Journal of Engineering, Science and Information Technology
- Vol. 6 (1) , 36-43
Open AccessImproving TDS Sensor Accuracy in an IoT-Based Fertigation Prototype Using Polynomial Regression Calibration and Interpolation
Accurate measurement of Total Dissolved Solids (TDS) is a critical requirement for hydroponic nutrient management, especially in automated fertigation systems that adjust nutrient concentrations based on plant age. However, non-industrial TDS sensors often exhibit significant fluctuations and non-linear errors, leading to unreliable nutrient dosing. This study proposes a calibration approach using second-order polynomial regression combined with interpolation to improve the accuracy of TDS measurements in an IoT-based fertigation prototype for lettuce hydroponics. The calibration was performed using reference TDS solutions and a digital TDS meter to ensure accurate measurements. The results show that the Mean Absolute Percentage Error (MAPE) decreased from 24.771% to 7.5768% during calibration, demonstrating a significant improvement in measurement accuracy. The calibrated sensor readings fall within the acceptable range for hydroponic nutrient control (±10%). This method provides a low-cost, reliable alternative for improving sensor accuracy in IoT fertigation systems.