Clianta Yudin Kharismasari
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Clianta Yudin Kharismasari has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Ari Hardianto
Department of Chemistry, Faculty of Mathematics and Natural Sciences, Universitas Padjadjaran, Sumedang 45363, Indonesia
2 shared publications - Irkham
Department of Chemistry, University of Padjadjaran, Sumedang 45363, Indonesia
2 shared publications - Muhammad Ihda Hamlu Liwaissunati Zein
Department of Chemistry “Giacomo Ciamician”, Alma Mater Studiorum - University of Bologna, Bologna 40126, Italy
2 shared publications - Salma Nur Zakiyyah
Department of Chemistry, Faculty of Mathematics and Natural Sciences, Universitas Padjadjaran, Bandung 45363, Indonesia
2 shared publications - Yeni Wahyuni Hartati
Department of Chemistry, Faculty of Mathematics and Natural Science, Universitas Padjadjaran, Sumedang 45363, Indonesia
2 shared publications - Mara Mirasoli
Department of Chemistry “Giacomo Ciamician”, Alma Mater Studiorum, University of Bologna, Tecnopolo di Rimini, Via Dario Campana 71, I-47922 Rimini, Italy
1 shared publication
Latest Publications
- Open Access
- 27 October 2026
- Published by International Association of Physical Chemists (IAPC) in ADMET and DMPK
- Vol. 14
CRISPR/Cas12-powered electrochemical biosensor for chikungunya virus DNA detection using gold-modified screen-printed carbon electrodes
Background and purpose: Chikungunya virus (CHIKV) remains a health concern because its symptoms overlap with dengue and Zika, often leading to misdiagnosis. Conventional diagnostic methods, including viral isolation, enzyme-linked immunosorbent assay (ELISA) and reverse transcription-polymerase chain reaction (RT-PCR), are time-consuming, costly, and dependent on specialized laboratories. This study aimed to develop a rapid, selective, and sensitive electrochemical biosensor integrated with CRISPR/Cas12 for CHIKV DNA detection. Experimental approach: A CHIKV-specific guide RNA targeting a conserved region of the E1 gene was designed in silico and selected by specificity score (99.15) and E-value (1.7). The platform used a gold particle-modified screen-printed carbon electrode (SPCE/Au) functionalized with a ferrocene-labelled DNA reporter. The electrode was characterized electrochemically, and the biosensor was tested for its response to CHIKV DNA, its selectivity against dengue virus (DENV) and SARS-CoV-2, and its detection performance across target concentrations. Key results: Au deposition enhanced the electrochemical properties of the electrode. Recognition of CHIKV DNA activated the CRISPR/Cas12 complex, whose collateral cleavage of the reporter reduced the ferrocene oxidation signal. The biosensor exhibited a concentration-dependent response over 0.01 to 10 ppb, with a limit of detection of 0.92 ppb and a limit of quantification of 2.77 ppb. The biosensor showed excellent selectivity against CHIKV competitors. Conclusion: This work shows that combining CRISPR/Cas12 collateral cleavage with a ferrocene-labelled reporter on SPCE/Au enables rapid, selective, and sensitive CHIKV detection. Validation with clinical samples is still needed. The platform supports early diagnosis and disease surveillance, in line with Sustainable Development Goal (SDG) 3 (Good Health and Well-being).
- 27 October 2026
- Published by International Association of Physical Chemists (IAPC) in ADMET and DMPK
- Vol. 14
Open AccessCRISPR/Cas12-powered electrochemical biosensor for chikungunya virus DNA detection using gold-modified screen-printed carbon electrodes
Background and purpose: Chikungunya virus (CHIKV) remains a health concern because its symptoms overlap with dengue and Zika, often leading to misdiagnosis. Conventional diagnostic methods, including viral isolation, enzyme-linked immunosorbent assay (ELISA) and reverse transcription-polymerase chain reaction (RT-PCR), are time-consuming, costly, and dependent on specialized laboratories. This study aimed to develop a rapid, selective, and sensitive electrochemical biosensor integrated with CRISPR/Cas12 for CHIKV DNA detection. Experimental approach: A CHIKV-specific guide RNA targeting a conserved region of the E1 gene was designed in silico and selected by specificity score (99.15) and E-value (1.7). The platform used a gold particle-modified screen-printed carbon electrode (SPCE/Au) functionalized with a ferrocene-labelled DNA reporter. The electrode was characterized electrochemically, and the biosensor was tested for its response to CHIKV DNA, its selectivity against dengue virus (DENV) and SARS-CoV-2, and its detection performance across target concentrations. Key results: Au deposition enhanced the electrochemical properties of the electrode. Recognition of CHIKV DNA activated the CRISPR/Cas12 complex, whose collateral cleavage of the reporter reduced the ferrocene oxidation signal. The biosensor exhibited a concentration-dependent response over 0.01 to 10 ppb, with a limit of detection of 0.92 ppb and a limit of quantification of 2.77 ppb. The biosensor showed excellent selectivity against CHIKV competitors. Conclusion: This work shows that combining CRISPR/Cas12 collateral cleavage with a ferrocene-labelled reporter on SPCE/Au enables rapid, selective, and sensitive CHIKV detection. Validation with clinical samples is still needed. The platform supports early diagnosis and disease surveillance, in line with Sustainable Development Goal (SDG) 3 (Good Health and Well-being).
- Open Access
- 30 March 2026
- Published by International Association of Physical Chemists (IAPC) in Journal of Electrochemical Science and Engineering
- Vol. 16, 3077
Parameter selection of cerium oxide anodic electrodeposition on screen-printed carbon electrodes using response surface methodology for nucleic acid based biosensors
Screen-printed carbon electrodes (SPCEs) modified with cerium oxide (ceria) have attracted considerable attention due to their outstanding stability and electrochemical performance, making them promising candidates for sensor and biosensor applications. However, the anodic electrodeposition of ceria on SPCEs involves multiple parameters that may strongly influence film formation and electrochemical behaviour, yet these factors have not been systematically optimized. This study aimed to determine and optimize the key parameters affecting anodic electrodeposition of ceria on SPCEs using cyclic voltammetry (CV) and response surface methodology. All four main parameters, namely UV irradiation time, distance between the SPCE and UV lamp, cerium nitrate concentration and the number of CV cycles, significantly influence the anodic electrodeposition process of ceria, shown by the statistical analysis (p <0.05). The optimized SPCE/ceria electrode exhibited improved electrochemical performance, with an average peak current of 44.158 μA and a relative standard deviati-on (RSD) of 2.68 %. This optimized SPCE/ceria was subsequently tested for guanine oxidetion using differential pulse voltammetry with an immobilized RNA probe and produced good repeatability with an RSD value of 2.37 %. The findings underscore the importance of parameter optimization to enhance the reproducibility and sensitivity of SPCE/ceria electrodes, demonstrating their strong potential for future biosensing applications.
- 30 March 2026
- Published by International Association of Physical Chemists (IAPC) in Journal of Electrochemical Science and Engineering
- Vol. 16, 3077
Open AccessParameter selection of cerium oxide anodic electrodeposition on screen-printed carbon electrodes using response surface methodology for nucleic acid based biosensors
Screen-printed carbon electrodes (SPCEs) modified with cerium oxide (ceria) have attracted considerable attention due to their outstanding stability and electrochemical performance, making them promising candidates for sensor and biosensor applications. However, the anodic electrodeposition of ceria on SPCEs involves multiple parameters that may strongly influence film formation and electrochemical behaviour, yet these factors have not been systematically optimized. This study aimed to determine and optimize the key parameters affecting anodic electrodeposition of ceria on SPCEs using cyclic voltammetry (CV) and response surface methodology. All four main parameters, namely UV irradiation time, distance between the SPCE and UV lamp, cerium nitrate concentration and the number of CV cycles, significantly influence the anodic electrodeposition process of ceria, shown by the statistical analysis (p <0.05). The optimized SPCE/ceria electrode exhibited improved electrochemical performance, with an average peak current of 44.158 μA and a relative standard deviati-on (RSD) of 2.68 %. This optimized SPCE/ceria was subsequently tested for guanine oxidetion using differential pulse voltammetry with an immobilized RNA probe and produced good repeatability with an RSD value of 2.37 %. The findings underscore the importance of parameter optimization to enhance the reproducibility and sensitivity of SPCE/ceria electrodes, demonstrating their strong potential for future biosensing applications.