Lars van Krimpen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Lars van Krimpen has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
- Anand Thiyagarajah
Cardio-Thoracic Unit, Bordeaux University Hospital (CHU), F-33600 Pessac-Bordeaux, France
1 shared publication - Antoine Da Costa
Department of Cardiology Jean Monnet University Saint‐Etienne France
1 shared publication - Arlene John
University of Twente
1 shared publication - Benjamin Sacristan
Department of Cardiac Pacing and Electrophysiology, Hopital Cardiologique du Haut-Leveque, Bordeaux University Hospital (CHU) , 1 Avenue de Magellan, Pessac Cedex 33604
1 shared publication - Josselin Duchateau
Department of Cardiac Electrophysiology, Hôpital Cardiologique du Haut-Lévêque, Bordeaux University Hospital, Pessac, France; IHU LIRYC, Université de Bordeaux–Inserm U1045 , Pessac
1 shared publication - Karim Benali
IHU Liryc, Electrophysiology and Heart Modeling Institute, University of Bordeaux , Bordeaux F-33600
1 shared publication
Latest Publications
- Open Access
A Multi-Center Trained Residual Neural Network for Robust Classification of Atrial High-Rate Episodes in Remotely Monitored Pacemakers and Defibrillators
Remote monitoring of pacemakers and defibrillators increases patient safety but also increases clinical workload. Review of atrial high-rate episodes is particularly demanding as episodes can contain atrial tachycardia or atrial fibrillation (AT/AF), noise, or far-field oversensing (FFO). Automatic review of atrial high-rate episodes by an Artificial Intelligence (AI) model can decrease the workload of remote monitoring, provided it maintains high sensitivity for true atrial tachycardia. A residual network is trained using a center-level fourfold cross validation. The four resulting models achieved a precision of 97.2–99.4% for AT/AF, 93.1–97.7% for noise, and 75.4–94.4% for FFO, while maintaining high sensitivity 98.9–99.3% for AT/AF. The four models were combined through averaging prediction probabilities to create an ensemble model. Thresholding ensemble predictions with probability > 95% resulted in a robust ensemble model that made only two errors (<0.1%) after reviewing 3925 episodes (91.9%) of the total 4271 episodes. This shows how AI models can reliably assist in remote monitoring. Future research should be aimed at classification models for other episode types and clinical validation of AI models to assist remote monitoring of pacemakers and defibrillators.
Open AccessA Multi-Center Trained Residual Neural Network for Robust Classification of Atrial High-Rate Episodes in Remotely Monitored Pacemakers and Defibrillators
Remote monitoring of pacemakers and defibrillators increases patient safety but also increases clinical workload. Review of atrial high-rate episodes is particularly demanding as episodes can contain atrial tachycardia or atrial fibrillation (AT/AF), noise, or far-field oversensing (FFO). Automatic review of atrial high-rate episodes by an Artificial Intelligence (AI) model can decrease the workload of remote monitoring, provided it maintains high sensitivity for true atrial tachycardia. A residual network is trained using a center-level fourfold cross validation. The four resulting models achieved a precision of 97.2–99.4% for AT/AF, 93.1–97.7% for noise, and 75.4–94.4% for FFO, while maintaining high sensitivity 98.9–99.3% for AT/AF. The four models were combined through averaging prediction probabilities to create an ensemble model. Thresholding ensemble predictions with probability > 95% resulted in a robust ensemble model that made only two errors (<0.1%) after reviewing 3925 episodes (91.9%) of the total 4271 episodes. This shows how AI models can reliably assist in remote monitoring. Future research should be aimed at classification models for other episode types and clinical validation of AI models to assist remote monitoring of pacemakers and defibrillators.