Vera Ivanova
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Vera Ivanova has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Felix Bulatbayev
Abylkas Saginov Karaganda Technical University
2 shared publications - Victoria Tsypkina
Tashkent State Technical University Named after Islam Karimov
2 shared publications - Yuliya Bulatbayeva
Abylkas Saginov Karaganda Technical University
2 shared publications - Gaukhar Alpanova
Abylkas Saginov Karaganda Technical University
1 shared publication - Rauan Kossymbayev
Abylkas Saginov Karaganda Technical University
1 shared publication Rauan Kosymbayev
Abylkas Saginov Karaganda Technical University
1 shared publication
Latest Publications
- 23 September 2026
- Published by Karaganda Technical University named after Abylkas Saginov in Trudy Universiteta
- Vol. 3 (104)
Analysis of Technological Disturbances and Development of an Intelligent Diagnostic System for Emergency Situations at 500 kV Substations in the Power System of Кazakhstan
This article examines the problem of improving the reliability of high‑voltage substations, particularly 500 kV facilities, which are critical elements of the energy infrastructure of the Republic of Kazakhstan. The operational features of such substations and typical emergency situations – including short circuits, circuit breaker failures, overheating of connections, and insulation breakdowns – have been analyzed. Statistical data provided by the system operator KEGOC indicate an increase in the number of technological disturbances, especially under conditions of equipment wear and growing load on the power system. Based on the obtained data, the need to develop an intelligent diagnostic system capable of detecting the development of emergency states in real time has been substantiated. The study presents a classification of emergencies, a review of modern diagnostic methods, and the concept of building a hybrid monitoring system integrated with SCADA digital platforms and relay protection devices. Special attention is given to the analysis of existing domestic and international solutions and the identification of their limitations in the context of the Kazakhstani power system. The results of the research are aimed at creating a scientific and practical basis for the implementation of digital solutions in the energy sector and reducing the risks of technological disturbances.
- 23 September 2026
- Published by Karaganda Technical University named after Abylkas Saginov in Trudy Universiteta
- Vol. 3 (104)
Analysis of Technological Disturbances and Development of an Intelligent Diagnostic System for Emergency Situations at 500 kV Substations in the Power System of Кazakhstan
This article examines the problem of improving the reliability of high‑voltage substations, particularly 500 kV facilities, which are critical elements of the energy infrastructure of the Republic of Kazakhstan. The operational features of such substations and typical emergency situations – including short circuits, circuit breaker failures, overheating of connections, and insulation breakdowns – have been analyzed. Statistical data provided by the system operator KEGOC indicate an increase in the number of technological disturbances, especially under conditions of equipment wear and growing load on the power system. Based on the obtained data, the need to develop an intelligent diagnostic system capable of detecting the development of emergency states in real time has been substantiated. The study presents a classification of emergencies, a review of modern diagnostic methods, and the concept of building a hybrid monitoring system integrated with SCADA digital platforms and relay protection devices. Special attention is given to the analysis of existing domestic and international solutions and the identification of their limitations in the context of the Kazakhstani power system. The results of the research are aimed at creating a scientific and practical basis for the implementation of digital solutions in the energy sector and reducing the risks of technological disturbances.
- Open Access
- 29 April 2026
- Published by Private Company Technology Center in Eastern-European Journal of Enterprise Technologies
- Vol. 2 (8 (140)) , 29-40
Development of a method for energy-efficient control of parallel pump units using the covariance matrix adaptation evolution strategy
The object of the study is a pumping station with four parallel-connected centrifugal pump units driven by asynchronous electric motors. The problem to be solved is that modern stations, partially equipped with variable frequency drive (VFDs), allow only maintaining the head without observing allowable modes, failing to ensure reliability and energy efficiency. This leads to rapid wear and efficiency reduction. The solution lies in optimizing energy consumption and keeping operating points within the POR (preferred operating region), to prevent accelerated wear. The essence of the results obtained lies in the development of a method for energy-efficient control based on the CMA-ES strategy integrated with a model in MATLAB (California, USA). Experiments showed that the balanced strategy reduces energy consumption by 7% while maintaining equipment in the POR zone for 95.8% of the time. Comparative analysis showed that a configuration with two VFDs is a rational compromise, limiting energy overconsumption to 25% relative to systems fully equipped with VFDs. These results allowed to solve the specified problem due to the introduction of a block performing an analytical express assessment of the required number of units based on affinity laws, using adaptive penalty functions and CMA-ES tuning. This allowed excluding combinatorial enumeration and reducing the search time for the optimal solution to 60–80 seconds, ensuring speed unavailable to standard genetic algorithms. The conditions under which they can be used on practice involve the application of the developed method as a supervisory control (SCADA) for water supply pumping stations to generate control setpoints with a periodicity of 1–2 minutes without the need for complete equipment replacement.
- 29 April 2026
- Published by Private Company Technology Center in Eastern-European Journal of Enterprise Technologies
- Vol. 2 (8 (140)) , 29-40
Open AccessDevelopment of a method for energy-efficient control of parallel pump units using the covariance matrix adaptation evolution strategy
The object of the study is a pumping station with four parallel-connected centrifugal pump units driven by asynchronous electric motors. The problem to be solved is that modern stations, partially equipped with variable frequency drive (VFDs), allow only maintaining the head without observing allowable modes, failing to ensure reliability and energy efficiency. This leads to rapid wear and efficiency reduction. The solution lies in optimizing energy consumption and keeping operating points within the POR (preferred operating region), to prevent accelerated wear. The essence of the results obtained lies in the development of a method for energy-efficient control based on the CMA-ES strategy integrated with a model in MATLAB (California, USA). Experiments showed that the balanced strategy reduces energy consumption by 7% while maintaining equipment in the POR zone for 95.8% of the time. Comparative analysis showed that a configuration with two VFDs is a rational compromise, limiting energy overconsumption to 25% relative to systems fully equipped with VFDs. These results allowed to solve the specified problem due to the introduction of a block performing an analytical express assessment of the required number of units based on affinity laws, using adaptive penalty functions and CMA-ES tuning. This allowed excluding combinatorial enumeration and reducing the search time for the optimal solution to 60–80 seconds, ensuring speed unavailable to standard genetic algorithms. The conditions under which they can be used on practice involve the application of the developed method as a supervisory control (SCADA) for water supply pumping stations to generate control setpoints with a periodicity of 1–2 minutes without the need for complete equipment replacement.
- 19 March 2026
- Published by Karaganda Technical University named after Abylkas Saginov in Trudy Universiteta
- Vol. 1 (102)
Enhancing the Energy Efficiency of Parallel-operated Pump Units Via a Genetic Algorithm
The article examines the application of a genetic algorithm to improve the energy efficiency and reliability of pump units operating in parallel. Modeling was carried out in the Matlab&Simulink environment, enabling a detailed analysis of the dynamics of parallel operation of centrifugal pumps. The control inputs were the frequencies of four drives, and the criteria were maintaining the required pressure while minimizing total power and observing hydraulic constraints. A series of computational experiments demonstrated how operator settings and objective-function weights affect convergence speed and solution quality. The results show a stable reduction in energy consumption while preserving operating reliability. Based on the analysis, practical recommendations are proposed for selecting genetic-algorithm parameters for pump-system optimization tasks.
- 19 March 2026
- Published by Karaganda Technical University named after Abylkas Saginov in Trudy Universiteta
- Vol. 1 (102)
Enhancing the Energy Efficiency of Parallel-operated Pump Units Via a Genetic Algorithm
The article examines the application of a genetic algorithm to improve the energy efficiency and reliability of pump units operating in parallel. Modeling was carried out in the Matlab&Simulink environment, enabling a detailed analysis of the dynamics of parallel operation of centrifugal pumps. The control inputs were the frequencies of four drives, and the criteria were maintaining the required pressure while minimizing total power and observing hydraulic constraints. A series of computational experiments demonstrated how operator settings and objective-function weights affect convergence speed and solution quality. The results show a stable reduction in energy consumption while preserving operating reliability. Based on the analysis, practical recommendations are proposed for selecting genetic-algorithm parameters for pump-system optimization tasks.