Yanan Yu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Yanan Yu has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Kai Wang
Beijing Orient Institute of Measurement and Test, Beijing, China
1 shared publication - Lushuai Qian
College of Mechanical and Electrical Engineering, China Jiliang University, Hangzhou, China
1 shared publication - Shengshi Chen
College of Mechanical and Electrical Engineering, China Jiliang University, Hangzhou, China
1 shared publication - Suan Xu
College of Mechanical and Electrical Engineering, China Jiliang University, Hangzhou, China
1 shared publication - Yaqiong Fu
College of Mechanical and Electrical Engineering, China Jiliang University, Hangzhou, China
1 shared publication
Latest Publications
- 16 April 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 75 (00189456) , 1-10
Measurement and Correction of the Resistor Load Effect Under Low-Pressure Conditions
The measurement of the load effect of the shunt resistor under low-pressure conditions is necessary for accurate current measurement, especially in aerospace applications such as power system fault diagnosis and monitoring, where shunt resistors are used for high-current sensing. In this paper, a measurement system to evaluate the resistor load effect under low-pressure conditions is designed and experimentally investigated, featuring a resistance measurement module, a pressure control module, and a temperature control module. In the pressure control module, a vacuum pump, an air reservoir, solenoid valves, and pressure sensors are applied to set and maintain various pressure test conditions in a vacuum chamber. The air reservoir is connected in series between the vacuum pump and the vacuum chamber to enhance the stability of pressure control. Experiments are performed to quantify the resistor load effect under low-pressure conditions by measuring its temperature, load, and pressure coefficients. Afterward, the resistance variation with temperature, load power, and pressure is characterized by polynomial models, which is then used to establish a resistance error correction model. Finally, a current compensation scheme is designed to verify the improvement in current measurement accuracy achieved by correction of the shunt resistor load effect under low-pressure conditions. The accuracy of the corrected current measurement is improved by one order of magnitude.
- 16 April 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 75 (00189456) , 1-10
Measurement and Correction of the Resistor Load Effect Under Low-Pressure Conditions
The measurement of the load effect of the shunt resistor under low-pressure conditions is necessary for accurate current measurement, especially in aerospace applications such as power system fault diagnosis and monitoring, where shunt resistors are used for high-current sensing. In this paper, a measurement system to evaluate the resistor load effect under low-pressure conditions is designed and experimentally investigated, featuring a resistance measurement module, a pressure control module, and a temperature control module. In the pressure control module, a vacuum pump, an air reservoir, solenoid valves, and pressure sensors are applied to set and maintain various pressure test conditions in a vacuum chamber. The air reservoir is connected in series between the vacuum pump and the vacuum chamber to enhance the stability of pressure control. Experiments are performed to quantify the resistor load effect under low-pressure conditions by measuring its temperature, load, and pressure coefficients. Afterward, the resistance variation with temperature, load power, and pressure is characterized by polynomial models, which is then used to establish a resistance error correction model. Finally, a current compensation scheme is designed to verify the improvement in current measurement accuracy achieved by correction of the shunt resistor load effect under low-pressure conditions. The accuracy of the corrected current measurement is improved by one order of magnitude.