Taehyun Joo
Research Subjects
Taehyun Joo has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Hyun Jin Ahn
Department of Internal Medicine and Cardiovascular Center, Seoul National University Hospital , 101 Daehak-ro, Jongno-gu, Seoul 03080
1 shared publication - Jung-Woo Son
Division of Cardiology, Department of Internal Medicine, Yonsei University, Wonju College of Medicine, Wonju, Korea
1 shared publication - Min-Soo Ahn
Division of Cardiology, Department of Internal Medicine, Wonju Severance Christian Hospital, Yonsei University Wonju College of Medicine, Wonju, Republic of Korea
1 shared publication - Mineok Chang
Cardiovascular Center, Seoul National University Hospital, Seoul 03080, Korea
1 shared publication - Sang Jun Lee
Division of Cardiology, Department of Internal Medicine, Wonju Severance Christian Hospital, Yonsei University Wonju College of Medicine, Wonju, Republic of Korea
1 shared publication - Sang-Jin Han
Division of Cardiology, Hallym University Sacred Heart Hospital, Hallym University College of Medicine, Anyang, Korea
1 shared publication
Latest Publications
- Open Access
- 24 April 2026
- Published by JMIR Publications Inc. in JMIR Medical Informatics
- Vol. 14 (1) , e83127
Deep Learning Model Using Transfer Learning for Detecting Left Ventricular Systolic Dysfunction: Retrospective Algorithm Development and Validation Study
Background: Artificial intelligence–augmented electrocardiogram (AI-ECG) models for detecting left ventricular systolic dysfunction (LVSD) often exhibit degraded performance in patients with comorbidities. Objective: This study aimed to introduce and validate a recalibration method using longitudinal patient data to enhance prediction accuracy and simulate its clinical utility for ongoing monitoring. Methods: We conducted a multicenter, retrospective cohort study using data from 2 hospitals in Korea. A dataset of paired transthoracic echocardiograms (TTEs) and electrocardiograms (ECGs) matched within a 2-week interval was constructed, separating pairs into baseline (first for each patient) and follow-up assessments. In addition to conventional supervised learning, we developed a patient-wise recalibration strategy that incorporated historical left ventricular ejection fraction measurements and prior AI-ECG outputs to adjust for future predictions, thus empirically mitigating confounding effects. Pretraining was also implemented to enhance the model’s performance. Results: The recalibrated 12-lead DeepECG LVSD model achieved an area under the receiver operating curve of 0.956 (95% CI 0.946‐0.965) for internal validation and 0.940 (95% CI 0.936‐0.945) for external validation of follow-up TTE-ECG pairs. The uncalibrated 12-lead DeepECG LVSD model also showed modest performance, with an area under the receiver operating curve of 0.953 (95% CI 0.941‐0.965) in the internal validation and 0.947 (95% CI 0.943‐0.951) in the external validation when tested on baseline TTE-ECG pairs. Recalibration yielded statistically significant improvements in the 12-lead DeepECG LVSD models ( P <.001), with enhanced and more balanced performance across all clinical subgroups. Conclusions: Patient-wise recalibration improved accuracy and consistency across various comorbidities by mitigating performance degradation and bias. This broadens the application of AI-ECG for LVSD detection from low-risk screening to high-risk longitudinal monitoring.
- 24 April 2026
- Published by JMIR Publications Inc. in JMIR Medical Informatics
- Vol. 14 (1) , e83127
Open AccessDeep Learning Model Using Transfer Learning for Detecting Left Ventricular Systolic Dysfunction: Retrospective Algorithm Development and Validation Study
Background: Artificial intelligence–augmented electrocardiogram (AI-ECG) models for detecting left ventricular systolic dysfunction (LVSD) often exhibit degraded performance in patients with comorbidities. Objective: This study aimed to introduce and validate a recalibration method using longitudinal patient data to enhance prediction accuracy and simulate its clinical utility for ongoing monitoring. Methods: We conducted a multicenter, retrospective cohort study using data from 2 hospitals in Korea. A dataset of paired transthoracic echocardiograms (TTEs) and electrocardiograms (ECGs) matched within a 2-week interval was constructed, separating pairs into baseline (first for each patient) and follow-up assessments. In addition to conventional supervised learning, we developed a patient-wise recalibration strategy that incorporated historical left ventricular ejection fraction measurements and prior AI-ECG outputs to adjust for future predictions, thus empirically mitigating confounding effects. Pretraining was also implemented to enhance the model’s performance. Results: The recalibrated 12-lead DeepECG LVSD model achieved an area under the receiver operating curve of 0.956 (95% CI 0.946‐0.965) for internal validation and 0.940 (95% CI 0.936‐0.945) for external validation of follow-up TTE-ECG pairs. The uncalibrated 12-lead DeepECG LVSD model also showed modest performance, with an area under the receiver operating curve of 0.953 (95% CI 0.941‐0.965) in the internal validation and 0.947 (95% CI 0.943‐0.951) in the external validation when tested on baseline TTE-ECG pairs. Recalibration yielded statistically significant improvements in the 12-lead DeepECG LVSD models ( P <.001), with enhanced and more balanced performance across all clinical subgroups. Conclusions: Patient-wise recalibration improved accuracy and consistency across various comorbidities by mitigating performance degradation and bias. This broadens the application of AI-ECG for LVSD detection from low-risk screening to high-risk longitudinal monitoring.