Ilse Arreola
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Ilse Arreola has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Ariosto Medina
Instituto de Investigaciones en Metalurgia y Materiales, Universidad Michoacana de San Nicolás de Hidalgo, Av. J. Múgica S/N, Morelia 58030, Michoacán, Mexico
2 shared publications - Engelbert Huape Padilla
Universidad Michoacana de San Nicolás de Hidalgo image/svg+xml
2 shared publications - Hector Carreon
Instituto de Investigación en Metalurgia y Materiales, Universidad Michoacana de San Nicolás de Hidalgo, Morelia, Mexico
2 shared publications - Jose Luis Bernal Ponce
National Technological Institute of Mexico/Technological Institute of Orizaba, Orizaba, Mexico, Orizaba, Mexico, Mexico
2 shared publications - Martin Flores
Departamento de Ingeniería de Proyectos, Centro Universitario de Ciencias Exactas e Ingenierías (CUCEI), Universidad de Guadalajara, Guadalajara 44430, Jalisco, Mexico
2 shared publications
Latest Publications
- Open Access
Electrochemical Corrosion Behavior of HiPIMS-Deposited Diamond-like Carbon (DLC) Coatings on AISI 52100 Steel in Synthetic Seawater
This manuscript evaluates the electrochemical corrosion resistance of diamond-like carbon (DLC) coatings deposited via High-Power Impulse Magnetron Sputtering (HiPIMS) on AISI 52100 steel in synthetic seawater. While AISI 52100 steel is valued for its hardness, it is highly susceptible to localized and uniform corrosion in chloride-rich marine environments. In this study, samples were characterized using Raman spectroscopy to analyze sp2/sp3 bonding, and their corrosion behavior was assessed through potentiodynamic polarization, linear polarization resistance (LPR), and electrochemical impedance spectroscopy (EIS) over 24 h of immersion. Results demonstrated that the DLC coatings significantly enhanced electrochemical stability, shifting corrosion potentials toward more noble values and reducing the corrosion current density from (1.81 ± 0.12) × 10−7 to (1.03 ± 0.09) × 10−9 mA·cm−2. EIS data revealed high polarization resistance and effective barrier properties, despite a calculated total porosity of 3.06% resulting from intrinsic micro-defects. Although localized subsurface degradation and minor flaking were observed at defect sites, the HiPIMS-deposited DLC coatings effectively mitigated the corrosive impact of synthetic seawater, providing a significant contribution to the electrochemical barrier despite the persistence of electrolyte accessibility mediated by localized defects.
Open AccessElectrochemical Corrosion Behavior of HiPIMS-Deposited Diamond-like Carbon (DLC) Coatings on AISI 52100 Steel in Synthetic Seawater
This manuscript evaluates the electrochemical corrosion resistance of diamond-like carbon (DLC) coatings deposited via High-Power Impulse Magnetron Sputtering (HiPIMS) on AISI 52100 steel in synthetic seawater. While AISI 52100 steel is valued for its hardness, it is highly susceptible to localized and uniform corrosion in chloride-rich marine environments. In this study, samples were characterized using Raman spectroscopy to analyze sp2/sp3 bonding, and their corrosion behavior was assessed through potentiodynamic polarization, linear polarization resistance (LPR), and electrochemical impedance spectroscopy (EIS) over 24 h of immersion. Results demonstrated that the DLC coatings significantly enhanced electrochemical stability, shifting corrosion potentials toward more noble values and reducing the corrosion current density from (1.81 ± 0.12) × 10−7 to (1.03 ± 0.09) × 10−9 mA·cm−2. EIS data revealed high polarization resistance and effective barrier properties, despite a calculated total porosity of 3.06% resulting from intrinsic micro-defects. Although localized subsurface degradation and minor flaking were observed at defect sites, the HiPIMS-deposited DLC coatings effectively mitigated the corrosive impact of synthetic seawater, providing a significant contribution to the electrochemical barrier despite the persistence of electrolyte accessibility mediated by localized defects.
- Open Access
- 30 April 2026
- Published by MDPI AG in Preprints.org
Electrochemical Corrosion Behavior of HiPIMS‑Deposited Diamond‑Like Carbon (DLC) Coatings on AISI 52100 Steel in Synthetic Seawater
This manuscript evaluates the electrochemical corrosion resistance of diamond-like car-bon (DLC) coatings deposited via High-Power Impulse Magnetron Sputtering (HiPIMS) on AISI 52100 steel in synthetic seawater. While AISI 52100 steel is valued for its hardness, it is highly susceptible to localized and uniform corrosion in chloride-rich marine environ-ments. In this study, samples were characterized using Raman spectroscopy to analyze sp2/sp3 bonding, and their corrosion behavior was assessed through potentiodynamic po-larization, linear polarization resistance (LPR), and electrochemical impedance spectros-copy (EIS) over 24 hours of immersion. Results demonstrated that the DLC coatings signif-icantly enhanced electrochemical stability, shifting corrosion potentials toward more no-ble values and reducing corrosion current densities by several orders of magnitude com-pared to the uncoated substrate. EIS data revealed high polarization resistance and effec-tive barrier properties, despite a calculated total porosity of 3.06% resulting from intrinsic micro-defects. Although localized subsurface degradation and minor flaking were ob-served at defect sites, the HiPIMS-deposited DLC coatings effectively mitigated the corro-sive impact of synthetic seawater, providing a robust protective barrier for high-precision steel components.
- 30 April 2026
- Published by MDPI AG in Preprints.org
Open AccessElectrochemical Corrosion Behavior of HiPIMS‑Deposited Diamond‑Like Carbon (DLC) Coatings on AISI 52100 Steel in Synthetic Seawater
This manuscript evaluates the electrochemical corrosion resistance of diamond-like car-bon (DLC) coatings deposited via High-Power Impulse Magnetron Sputtering (HiPIMS) on AISI 52100 steel in synthetic seawater. While AISI 52100 steel is valued for its hardness, it is highly susceptible to localized and uniform corrosion in chloride-rich marine environ-ments. In this study, samples were characterized using Raman spectroscopy to analyze sp2/sp3 bonding, and their corrosion behavior was assessed through potentiodynamic po-larization, linear polarization resistance (LPR), and electrochemical impedance spectros-copy (EIS) over 24 hours of immersion. Results demonstrated that the DLC coatings signif-icantly enhanced electrochemical stability, shifting corrosion potentials toward more no-ble values and reducing corrosion current densities by several orders of magnitude com-pared to the uncoated substrate. EIS data revealed high polarization resistance and effec-tive barrier properties, despite a calculated total porosity of 3.06% resulting from intrinsic micro-defects. Although localized subsurface degradation and minor flaking were ob-served at defect sites, the HiPIMS-deposited DLC coatings effectively mitigated the corro-sive impact of synthetic seawater, providing a robust protective barrier for high-precision steel components.