XFXuyang Feng

Xuyang Feng

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Xuyang Feng has a total of 33 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Ultraflexible Multimodal Sensors with Stable Physical Sensing and Disposable Electrochemical Calibration for Long-Term Glucose Prediction

    by Xuyang Feng, Jiahe Zhou, Xianyu Wang, Binghao Wang

    Wearable electrochemical biosensors offer direct biochemical readouts but often suffer from enzyme deactivation, biofluid fluctuation, fouling, and calibration drift during prolonged on-body use. Here, we report an ultrathin (∼1.3 μm thick) multimodal sensing system that decouples whole-day physical monitoring from short-term disposable electrochemical calibration. The system integrates stable physical sensors for electrocardiogram, pulse, and temperature acquisition with a detachable electrochemical glucose module that provides personalized calibration labels during initial use. At the material level, the pulse sensor combines an embedded Ag nanowire network with a cracked Cr/MoO3/Cr/Au layer in an ultrathin polyimide matrix, enabling both strain sensitivity and cyclic stability. The resulting strain sensor shows a gauge factor of 5.49 in the 0–4% strain range, a response time of 55 ms, and durability over 15,000 stretching cycles. The detachable glucose sensor employs a co-crosslinked porous enzymatic matrix to delay active-site saturation, achieving a broad linear range of 0–20 mM. After three days of personalized calibration, a random-forest model using 60 s recordings of electrocardiogram, pulse, and temperature signals yields an overall tolerance-based accuracy of 81.36% and a mean absolute relative difference (MARD) of 9.12%. Furthermore, in individual on-body tracking over one day and 15 days, the glucose predictions achieved an accuracy of at least 80%. This stable-physical-sensing/disposable-electrochemical-calibration architecture provides a practical strategy for personalized glucose prediction while mitigating the long-term instability of wearable electrochemical biosensors.

  • Reusable Modular Wearable Bioelectronics for Low-Carbon Task-Adaptive Health Monitoring

    by Xianyu Wang, Xuyang Feng, Haoyang Wang, Yujie Cui, Limei Liu, Binghao Wang

    Wearable bioelectronics are increasingly expected to support personalized, multiparametric, and closed-loop health monitoring, yet most systems rely on monolithic integration that limits task adaptability and increases hardware redundancy and environmental burden. Here, we present a reusable modular wearable platform that decouples a common digital back end from interchangeable analog front-end and sensing modules. This architecture enables on-demand reconfiguration across electrophysiological, mechanical, thermal, and electrochemical monitoring tasks without redesigning the complete system. Manufacturing-stage carbon-footprint analysis shows that selective reuse of carbon-intensive back-end electronics reduces emissions compared with monolithic integration, with greater benefits as task complexity increases. The platform captures muscle activity, heart-rate dynamics, electroencephalogram α-band features, body temperature, tactile, and glucose levels and wirelessly links physiological sensing to a stretchable chip-on-array LED display for real-time on-skin visualization and threshold-triggered alerts. This work provides a reusable, task-adaptive, and low-carbon hardware framework for scalable personalized wearable bioelectronics.


  • Open Access

    Highly flexible vertical electrolyte-gated metal oxide transistors for neuromorphic electronics

    by Qing Ma, Xuyang Feng, Haoyang Wang, Shisheng Chen, Di Xue, Xianyu Wang, Chen Li, Yao Yao, Limei Liu, Enbo Xue, et al.

    Metal oxide-based electrolyte-gated transistors (EGTs) are attractive for low-power biosensors and neuromorphic systems, but their electrical characteristics has been constrained by a fundamental trade-off between channel downscaling and electrical double layer (EDL) capacitance, resulting in limited transconductance and metrics inferior to that of organic counterparts. Here, we report high-performance and ultraflexible indium gallium zinc oxide (IGZO) EGTs enabled by a vertical device architecture and a nanoscale channel length. We systematically examined how device geometries—including the IGZO-electrode contact area, IGZO thickness, and semiconductor-electrode interface—affect the electrical properties and EDL capacitance, thereby revealing how the vertical structure decouples the channel length from the EDL formation area. Optimized vertical EGTs (vEGTs) exhibit a transconductance of up to 22.5 mS, an on/off current ratio of ~10 5 , ultralow operating voltages below 0.5 V, and pronounced ultraflexibility, maintaining stable performance when bent to a radius of 0.3 mm. Furthermore, vEGTs were integrated into inverter, NOR, and NAND logic circuits operating at voltages as low as 0.1 V. Finally, we demonstrate a closed-loop neuromorphic system in which the slow attenuation of the paired-pulse facilitation index enables adaptive and wireless control of a wearable display in response to a skin-interfaced sensor.


  • Bottom-Up Absorptive and Stretchable Plasmonic Tape for Field-Deployable In Vivo Fruit Safety Surveillance

    by Limei Liu, Ziyang Hu, Xuyang Feng, Weifan Pan, Tingfeng Dai, Taimin Sun, Hao Wang, Kuo Yang, Ting-Hui Xiao, Yasutaka Kitahama, et al.

    Food safety surveillance for fresh produce requires analytical tools that operate directly on wet, curved plant and fruit surfaces, yet gold-standard methods and flexible surface-enhanced Raman scattering (SERS) substrates are often destructive or unsuitable for in vivo use. Here, we present a bottom-up absorptive ultrathin plasmonic tape—SERS-active functional elastomeric (SAFE) tape—that conforms to wet surfaces and absorbs/transports analytes to plasmonic hotspots for quantitative, multiplex in vivo SERS readouts without substrate inversion. SAFE tape swells within seconds and achieves detection limits of 1 nM for pesticides and 1 μM for plant hormones, while maintaining high signal uniformity, mechanical durability, and long-term stability. Predictive models accurately quantify mixtures across a broad range (1 μM to 1 mM). The tape also detects Penicillium spp. up to two days before visible symptoms and enables real-time monitoring of pesticide and preservative degradation during growth and storage, providing a low-cost, field-deployable platform for food safety monitoring.