Bo Li
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Bo Li has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Wenxi Zhang
Aerospace Information Research Institute, Chinese Academy of Sciences, Beijing 100094, China
2 shared publications Xinxin Kong
University of Chinese Academy of Sciences
2 shared publicationsZhou Wu
University of Chinese Academy of Sciences
2 shared publicationsHanlin Zhu
1 shared publication- Hanlin Zhu
Aerospace Information Research Institute, Chinese Academy of Sciences, Beijing 100190, China
1 shared publication Wenxi Zhang
1 shared publication
Latest Publications
- 14 October 2026
- Published by Optica Publishing Group in Optics Letters
- Vol. 51 (20) , 5886-5889
Removal algorithm for crosstalk in dual-beam point-diffraction interferometry based on a four-beam interference model
We introduce what we believe to be a novel crosstalk-removal algorithm to eliminate phase errors in dual-beam point-diffraction interferometry. The method establishes a generalized four-beam interference error model. By using Fourier-carrier least-squares fitting and an iterative optimization based on micro-perturbation, crosstalk-induced error can be effectively eliminated. To the best of our knowledge, no relevant study on mitigating such four-beam interference errors has been previously reported.
- 14 October 2026
- Published by Optica Publishing Group in Optics Letters
- Vol. 51 (20) , 5886-5889
Removal algorithm for crosstalk in dual-beam point-diffraction interferometry based on a four-beam interference model
We introduce what we believe to be a novel crosstalk-removal algorithm to eliminate phase errors in dual-beam point-diffraction interferometry. The method establishes a generalized four-beam interference error model. By using Fourier-carrier least-squares fitting and an iterative optimization based on micro-perturbation, crosstalk-induced error can be effectively eliminated. To the best of our knowledge, no relevant study on mitigating such four-beam interference errors has been previously reported.
- Open Access
- 20 August 2026
- Published by MDPI AG in Applied Sciences
- Vol. 16 (16) , 8299
Compact Heterodyne Pinhole Point-Diffraction Interferometer with High Repeatability and Adjustable Contrast Based on Dual-Cascaded Acousto-Optic Modulators
Conventional pinhole point-diffraction interferometers (PPDIs) owe their popularity to a simple configuration, but that same configuration limits both the usable measurement aperture and the load the phase shifter can carry. Here, we propose a heterodyne phase-shifting point-diffraction interferometer (HPDI) based on dual-cascaded acousto-optic modulators (AOMs), which removes both limitations while keeping the configuration compact. The dual-cascaded AOM module integrates the functions of frequency shifting, beam splitting, and contrast modulation. By modulating its input RF power, the interference contrast can be flexibly adjusted. Simulation and experimental results verify the feasibility of the proposed HPDI, which achieves a measurement repeatability of 0.045 nm (RMS, with piston, tilt, and defocus removed) and agrees with an absolute shift-rotation calibration to within 3.3 nm (RMS).
- 20 August 2026
- Published by MDPI AG in Applied Sciences
- Vol. 16 (16) , 8299
Open AccessCompact Heterodyne Pinhole Point-Diffraction Interferometer with High Repeatability and Adjustable Contrast Based on Dual-Cascaded Acousto-Optic Modulators
Conventional pinhole point-diffraction interferometers (PPDIs) owe their popularity to a simple configuration, but that same configuration limits both the usable measurement aperture and the load the phase shifter can carry. Here, we propose a heterodyne phase-shifting point-diffraction interferometer (HPDI) based on dual-cascaded acousto-optic modulators (AOMs), which removes both limitations while keeping the configuration compact. The dual-cascaded AOM module integrates the functions of frequency shifting, beam splitting, and contrast modulation. By modulating its input RF power, the interference contrast can be flexibly adjusted. Simulation and experimental results verify the feasibility of the proposed HPDI, which achieves a measurement repeatability of 0.045 nm (RMS, with piston, tilt, and defocus removed) and agrees with an absolute shift-rotation calibration to within 3.3 nm (RMS).
- Open Access
- 27 April 2026
- Published by Elsevier in SSRN Electronic Journal
Compact heterodyne pinhole point-diffraction interferometer with high repeatability and adjustable contrast based on dual-cascaded acousto-optic modulators
We propose a compact heterodyne point-diffraction interferometer (PDI) based on dual-cascaded acousto-optic modulators (AOM), that featuring adjustable contrast and high repeatability. The novel dual-cascaded AOM module integrates the functions of frequency shifting, beam splitting, and contrast modulation. The incident beam is split into two parallel beam pairs with a frequency difference. Beams are evenly arranged around the optical axis of a focusing lens so they enter the diffraction pinhole together. By modulating the AOMs' input RF power, the interference contrast can be flexibly adjusted. Compared with traditional configurations, this system is not only more compact but also capable of measuring larger-aperture and higher-mass components. Simulation and experimental results verify the feasibility of the proposed PDI, achieving a measurement repeatability of less than 0.6 nm (RMS).
- 27 April 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessCompact heterodyne pinhole point-diffraction interferometer with high repeatability and adjustable contrast based on dual-cascaded acousto-optic modulators
We propose a compact heterodyne point-diffraction interferometer (PDI) based on dual-cascaded acousto-optic modulators (AOM), that featuring adjustable contrast and high repeatability. The novel dual-cascaded AOM module integrates the functions of frequency shifting, beam splitting, and contrast modulation. The incident beam is split into two parallel beam pairs with a frequency difference. Beams are evenly arranged around the optical axis of a focusing lens so they enter the diffraction pinhole together. By modulating the AOMs' input RF power, the interference contrast can be flexibly adjusted. Compared with traditional configurations, this system is not only more compact but also capable of measuring larger-aperture and higher-mass components. Simulation and experimental results verify the feasibility of the proposed PDI, achieving a measurement repeatability of less than 0.6 nm (RMS).