Anahita Azinfar
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Anahita Azinfar has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
Amir Behforouz
Department of Radiology, Faculty of Medicine, Mashhad University of Medical Sciences, Mashhad, Iran
1 shared publication- Amir Mahmoud Ahmadzadeh
Department of Radiology, School of Medicine, Mashhad University of Medical Sciences, Mashhad, Iran
1 shared publication - Hourieh Soleimani
Department of Radiology, Faculty of Medicine Mashhad University of Medical Sciences Mashhad Iran
1 shared publication - Lida Jarahi
Department of Community Medicine, Faculty of Medicine, Mashhad University of Medical Sciences, Mashhad, Iran
1 shared publication - Mahsa Akbari Oryani
Department of Pathology, Faculty of Medicine, Mashhad University of Medical Sciences, Mashhad. Iran
1 shared publication - Maryam Ghandhari
Student Research Committee, Faculty of Medicine, Mashhad University of Medical Sciences, Mashhad, Iran
1 shared publication
Latest Publications
- Open Access
- 1 August 2026
- Published by Brieflands in International Journal of Cancer Management
- Vol. 19 (1) , e168427
Association Between Computed Tomography Characteristics and Ultrasound-Based Risk Stratification in Incidental Thyroid Nodules of Oncologic Patients
Background: Incidental thyroid nodules (ITNs) are frequently detected in oncologic patients undergoing computed tomography (CT). However, the diagnostic accuracy of CT for these nodules, particularly in comparison with ultrasound-based Thyroid Imaging Reporting and Data System (TIRADS) and Korean Thyroid Imaging Reporting and Data System (K-TIRADS) classifications, remains unclear. Objectives: We evaluated the diagnostic accuracy of CT for characterizing high-risk sonographic patterns in ITNs in oncologic patients by comparing CT findings with ultrasound-based classifications. Methods: This retrospective study analyzed 420 oncologic patients who underwent contrast-enhanced chest CT. Of the 65 patients with ITNs, 55 were included in the final analysis, comprising 81 nodules. CT findings, including density, enhancement, calcification, and size, were compared with the TIRADS and K-TIRADS ultrasound classifications. Fine-needle aspiration (FNA) was performed when indicated according to the K-TIRADS criteria. Statistical analyses included the intraclass correlation coefficient (ICC), chi-squared tests, logistic regression, and receiver operating characteristic (ROC) curve analysis. Results: ROC analysis of enhancement-based prediction yielded an area under the curve of 0.86 (95% CI, 0.78 - 0.94) for K-TIRADS and 0.88 (95% CI, 0.80 - 0.94) for TIRADS. The optimal enhancement threshold for high-risk sonographic patterns was 38.8 Hounsfield units (HU). Diagnostic accuracy was 80.0% (95% CI, 69.0%-88.0%) for K-TIRADS and 78.0% (95% CI, 68.0%-87.0%) for TIRADS. Calcification was significantly associated with both TIRADS (P < 0.01) and K-TIRADS (P = 0.04). CT and ultrasound measurements of nodule size were strongly correlated (ICC = 0.96; P < 0.001). Follicular adenoma was the most common final diagnosis after FNA (63.2%). Conclusions: CT enhancement and calcification patterns provide complementary diagnostic value for ITNs in oncologic patients and may facilitate more targeted management. However, ultrasound remains essential for evaluating high-risk patterns. These findings suggest that CT may serve as a useful adjunct in ITN triage.
- 1 August 2026
- Published by Brieflands in International Journal of Cancer Management
- Vol. 19 (1) , e168427
Open AccessAssociation Between Computed Tomography Characteristics and Ultrasound-Based Risk Stratification in Incidental Thyroid Nodules of Oncologic Patients
Background: Incidental thyroid nodules (ITNs) are frequently detected in oncologic patients undergoing computed tomography (CT). However, the diagnostic accuracy of CT for these nodules, particularly in comparison with ultrasound-based Thyroid Imaging Reporting and Data System (TIRADS) and Korean Thyroid Imaging Reporting and Data System (K-TIRADS) classifications, remains unclear. Objectives: We evaluated the diagnostic accuracy of CT for characterizing high-risk sonographic patterns in ITNs in oncologic patients by comparing CT findings with ultrasound-based classifications. Methods: This retrospective study analyzed 420 oncologic patients who underwent contrast-enhanced chest CT. Of the 65 patients with ITNs, 55 were included in the final analysis, comprising 81 nodules. CT findings, including density, enhancement, calcification, and size, were compared with the TIRADS and K-TIRADS ultrasound classifications. Fine-needle aspiration (FNA) was performed when indicated according to the K-TIRADS criteria. Statistical analyses included the intraclass correlation coefficient (ICC), chi-squared tests, logistic regression, and receiver operating characteristic (ROC) curve analysis. Results: ROC analysis of enhancement-based prediction yielded an area under the curve of 0.86 (95% CI, 0.78 - 0.94) for K-TIRADS and 0.88 (95% CI, 0.80 - 0.94) for TIRADS. The optimal enhancement threshold for high-risk sonographic patterns was 38.8 Hounsfield units (HU). Diagnostic accuracy was 80.0% (95% CI, 69.0%-88.0%) for K-TIRADS and 78.0% (95% CI, 68.0%-87.0%) for TIRADS. Calcification was significantly associated with both TIRADS (P < 0.01) and K-TIRADS (P = 0.04). CT and ultrasound measurements of nodule size were strongly correlated (ICC = 0.96; P < 0.001). Follicular adenoma was the most common final diagnosis after FNA (63.2%). Conclusions: CT enhancement and calcification patterns provide complementary diagnostic value for ITNs in oncologic patients and may facilitate more targeted management. However, ultrasound remains essential for evaluating high-risk patterns. These findings suggest that CT may serve as a useful adjunct in ITN triage.
- 7 July 2026
- Published by SAGE Publications in Acta Radiologica
- Vol. 67 (8) , 692-704
Preoperative differentiation of adrenal pheochromocytoma and lipid-poor adenoma using CT-based radiomics: a systematic review and meta-analysis
Differentiating pheochromocytoma from lipid-poor adenoma (LPA) on conventional CT remains challenging because of overlapping imaging features. Radiomics captures relevant quantitative imaging information that maybe useful for this differentiation. We aimed to evaluate the diagnostic performance of CT-based radiomics for the preoperative differentiation of pheochromocytoma from LPA. PubMed, Scopus, Embase, and Web of Science were comprehensively searched from inception through October 13, 2025. Eligible studies applied CT-based radiomics to differentiate pheochromocytoma from LPA. Pooled sensitivity, specificity, likelihood ratios, diagnostic odds ratio, and area under the curve (AUC) were estimated. Statistical heterogeneity was assessed using I2 statistic and subgroup analyses were conducted to find their potential sources. Publication bias was assessed using Deek's funnel plot asymmetry test. After deduplication and thorough screening process, seven studies encompassing 1,272 patients met the inclusion criteria. Six studies were included in the meta-analysis, yielding a pooled sensitivity of 0.92 (95% CI, 0.83–0.97), specificity of 0.89 (95% CI, 0.79–0.94), and AUC of 0.85 (95% CI, 0.81–0.94). Subgroup analyses showed higher sensitivity in studies reporting image preprocessing (0.97 vs 0.83, P < 0.01). No considerable publication bias was detected ( P = 0.12). Nomogram models integrating radiomics with clinicoradiological features achieved significantly higher AUCs than radiomics-only models (0.95 vs 0.87, P = 0.004). In conclusion, CT-based radiomics demonstrated high accuracy for distinguishing pheochromocytoma from LPA, with unenhanced CT providing the strongest discrimination. Integration of radiomics with clinicoradiological variables further enhances performance. However, multicenter validation with standardized pipelines is needed for clinical translation.
- 7 July 2026
- Published by SAGE Publications in Acta Radiologica
- Vol. 67 (8) , 692-704
Preoperative differentiation of adrenal pheochromocytoma and lipid-poor adenoma using CT-based radiomics: a systematic review and meta-analysis
Differentiating pheochromocytoma from lipid-poor adenoma (LPA) on conventional CT remains challenging because of overlapping imaging features. Radiomics captures relevant quantitative imaging information that maybe useful for this differentiation. We aimed to evaluate the diagnostic performance of CT-based radiomics for the preoperative differentiation of pheochromocytoma from LPA. PubMed, Scopus, Embase, and Web of Science were comprehensively searched from inception through October 13, 2025. Eligible studies applied CT-based radiomics to differentiate pheochromocytoma from LPA. Pooled sensitivity, specificity, likelihood ratios, diagnostic odds ratio, and area under the curve (AUC) were estimated. Statistical heterogeneity was assessed using I2 statistic and subgroup analyses were conducted to find their potential sources. Publication bias was assessed using Deek's funnel plot asymmetry test. After deduplication and thorough screening process, seven studies encompassing 1,272 patients met the inclusion criteria. Six studies were included in the meta-analysis, yielding a pooled sensitivity of 0.92 (95% CI, 0.83–0.97), specificity of 0.89 (95% CI, 0.79–0.94), and AUC of 0.85 (95% CI, 0.81–0.94). Subgroup analyses showed higher sensitivity in studies reporting image preprocessing (0.97 vs 0.83, P < 0.01). No considerable publication bias was detected ( P = 0.12). Nomogram models integrating radiomics with clinicoradiological features achieved significantly higher AUCs than radiomics-only models (0.95 vs 0.87, P = 0.004). In conclusion, CT-based radiomics demonstrated high accuracy for distinguishing pheochromocytoma from LPA, with unenhanced CT providing the strongest discrimination. Integration of radiomics with clinicoradiological variables further enhances performance. However, multicenter validation with standardized pipelines is needed for clinical translation.
- 30 April 2026
- Published by SAGE Publications in Ultrasound
Diagnostic value of subcostal liver margin diameter measured by ultrasonography for identifying paediatric hepatomegaly
Introduction: Liver size varies with age, sex and body size. Ultrasonography is a widely used modality to evaluate liver size. While craniocaudal diameter diagnoses hepatomegaly, measuring liver diameter below the costal margin in the midclavicular line may offer a simpler alternative. This study evaluated the diagnostic value of subcostal liver margin diameter for identifying hepatomegaly. Methods: In this cross-sectional study, 42 patients with hepatomegaly and 42 healthy individuals under 18 years underwent liver measurements by ultrasonography at two radiology centres. Liver diameter below the costal margin through the midclavicular was obtained, and the statistical analysis using the receiver operating characteristic (ROC) curve analysis was made. Results: Mean subcostal diameter in patients with hepatomegaly was 44.05 ± 12.84 mm and was 11.65 ± 7.89 mm in controls. ROC curve analysis demonstrated a cut-off of 20.5 to 22.5 mm for the diagnosis of hepatomegaly. Considering 2 cm as the cut-off was great for diagnosing hepatomegaly in paediatric patients without considering age. Conclusion: The study demonstrated liver diameter below the costal margin as an alternative method for identifying hepatomegaly in paediatric patients. This simpler, potentially faster measurement approach may serve as a reliable diagnostic tool.
- 30 April 2026
- Published by SAGE Publications in Ultrasound
Diagnostic value of subcostal liver margin diameter measured by ultrasonography for identifying paediatric hepatomegaly
Introduction: Liver size varies with age, sex and body size. Ultrasonography is a widely used modality to evaluate liver size. While craniocaudal diameter diagnoses hepatomegaly, measuring liver diameter below the costal margin in the midclavicular line may offer a simpler alternative. This study evaluated the diagnostic value of subcostal liver margin diameter for identifying hepatomegaly. Methods: In this cross-sectional study, 42 patients with hepatomegaly and 42 healthy individuals under 18 years underwent liver measurements by ultrasonography at two radiology centres. Liver diameter below the costal margin through the midclavicular was obtained, and the statistical analysis using the receiver operating characteristic (ROC) curve analysis was made. Results: Mean subcostal diameter in patients with hepatomegaly was 44.05 ± 12.84 mm and was 11.65 ± 7.89 mm in controls. ROC curve analysis demonstrated a cut-off of 20.5 to 22.5 mm for the diagnosis of hepatomegaly. Considering 2 cm as the cut-off was great for diagnosing hepatomegaly in paediatric patients without considering age. Conclusion: The study demonstrated liver diameter below the costal margin as an alternative method for identifying hepatomegaly in paediatric patients. This simpler, potentially faster measurement approach may serve as a reliable diagnostic tool.