RYRamil S. Yagfarov

Ramil S. Yagfarov

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Ramil S. Yagfarov has a total of 11 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Novel osteosynthesis technique for post-traumatic impression deformities of the posterior aspect of the lateral tibial condyle

    by Ramil S. Yagfarov, Ягфаров Рамиль Салаватович, Igor A. Voronkevich, Воронкевич Игорь Алексеевич, Alexander Y. Kochish, Кочиш Александр Юрьевич, Dmitry V. Stafeev, Стафеев Дмитрий Викторович

    Background. Post-traumatic deformities of the posterolateral tibial plateau are associated with poor surgical outcomes, largely due to the technical difficulty of achieving anatomical reduction because of limited access to the damaged articular surface. Traditional osteosynthesis using buttress plates carries a certain complication rate and often necessitates implant removal. The aim of the study — to compare the anatomical and functional outcomes of the novel osteosynthesis technique versus the conventional technique for post-traumatic impression deformities of the posterior aspect of the lateral tibial condyle. Methods. A prospective cohort study with retrospective control was conducted. The prospective group included 25 patients with post-traumatic deformities of the posterolateral tibial condyle who were operated on using a newly developed technique. The retrospective group comprised 40 patients with similar pathology who underwent conventional surgery via an anterolateral approach with a proximal lateral tibial plate. Outcomes were assessed using the KSS, WOMAC, and VAS scores, as well as radiography and computed tomography (CT) at 3, 6, and 12 months postoperatively. Results. In the prospective group, all functional scores improved significantly: the median KSS increased from 50.0 to 92.0, the WOMAC score decreased from 40.0 to 6.0, and the VAS score dropped to 0.0 (p 0.001). The median residual impression on CT was 0.0 mm (complete reduction achieved in 72% of patients). Compared with the retrospective group, the prospective group showed significantly better outcomes: KSS — 92.0 vs. 69.5, WOMAC — 6.0 vs. 37.0, VAS — 0.0 vs. 2.0 (p 0.001), and residual impression on CT — 0.0 vs. 4.0 mm (p 0.001). The complication rate was 8.0% in the prospective group versus 25.0% in the retrospective group (p = 0.109). Conclusion. The proposed novel technique proved to be a safe and effective alternative to plate osteosynthesis for post-traumatic impression deformities of the posterior aspect of the lateral tibial condyle, providing complete impression reduction, favorable functional outcomes, and a trend toward fewer complications.

  • Topographic and anatomical basis of a novel surgical technique for the treatment of depression fractures and deformities of the proximal tibial epiphysis

    by Ramil S. Yagfarov, Igor A. Voronkevich, Dmitry A. Starchik, Alexander Yu. Kochish

    Objective: to provide a topographical-anatomical rationale for the safety and efficacy of a new surgical technique for treating patients with impression fractures and deformities of the posterolateral aspect of the proximal tibial epiphysis. Material and methods. The study was conducted on 11 non-fixed preparations of the lower extremities, obtained from 6 corpses that died at the age of 52 to 64 years. The experimental study was conducted in two series. In the first series, the proposed surgical technique was simulated on 3 cadaveric specimens, followed by dissection to assess the risk of damage to anatomical structures. In the second series, the procedure was performed on 8 specimens, after which horizontal sections were made and processed using epoxy plastination according to the established method, followed by morphometric analysis. Results. In the first experimental series, the technique of the proposed treatment method was refined, confirming the absence of risk to major neurovascular structures. In the second series, the shortest distances from the fixation screw to the neurovascular structures were determined. The popliteal vein was located at a distance of 20.1–24.8 mm, the popliteal artery at 16.2–23.2 mm, the tibial nerve at 17.8–24.5 mm, and the common peroneal nerve at 13.2–24.1 mm. Conclusion. An effective technique for the proposed method was experimentally developed. The anatomical safety of the intervention was confirmed: the tibial nerve and popliteal vessels are situated outside the risk zone. The identified risk of injury to the common peroneal nerve during mobilization of the fibular head is minimized by the correct execution of the technique.


  • Topographic and anatomical substantiation of a novel surgical technique for treating impression fractures and deformities of the proximal tibial epiphysis

    by Ramil S. Yagfarov, Igor A. Voronkevich, Dmitry A. Starchik, Aleksandr Yu. Kochish

    Objective: to substantiate the feasibility and safety of a new surgical treatment method for patients with impression fractures and deformities of the posterolateral proximal tibial epiphysis from a topographic and anatomical standpoint. Materials and Methods. The study was conducted on 11 unfixed lower limb specimens obtained from six deceased individuals aged 52 to 64 years. The experiment was performed in two series. In the first series, the proposed surgery was simulated on three specimens, followed by dissection to assess the risk of damage to anatomical structures. In the second series, horizontal cuts with epoxy plastination (according to the method by D.A. Starchik) were made on eight specimens after the operation, and morphometry was performed. Results. In the first series of experiments, the technique of the proposed treatment method was tested, and nonexistent risk of damage to important neurovascular structures was confirmed. In the second series, the shortest distances from the fixation screw to the neurovascular structures were determined. The popliteal vein, popliteal artery, tibial nerve, and common peroneal nerve were located at a distance of 20.1–24.8 mm, 16.2–23.2 mm, 17.8–24.5 mm, and 13.2–24.1 mm, correspondingly. Conclusion. The effective technique of the proposed method was experimentally developed. The anatomical safety of the intervention was confirmed: the tibial nerve and popliteal vessels were located outside the risk area. The identified risk of injury to the common peroneal nerve during fibular head mobilization is minimized by correct execution of the technique.

  • Mechanical justification of a new method of reconstruction of the posterolateral tibial plateau

    by Ramil S. Yagfarov, Igor A. Voronkevich, Oleg G. Zotov, Nikita A. Golubkov, Dmitry V. Stafeev, Alexandr I. Avdeev

    Introduction. Incorrect restoration of the articular surface of the tibial plateau and the limb axis leads to disruption of joint relationships and angular deformities in 19–26% of cases. Currently, numerous treatment options exist for deformities and impression fractures of the posterolateral tibial condyle (PLF), but there is no consensus on the optimal surgical strategy for treating the posterolateral tibial condyle. Objective: to evaluate and compare our proposed technique with two modern fixation methods in a mechanical test on plastic models: a lateral condylar plate and a volar palmar plate for distal radius metaphysis. Materials and Methods.The mechanical experiment was conducted at the Peter the Great St. Petersburg Polytechnical University using a Zwick/Roell Z100 universal testing machine. Uniaxial static compression of the posterolateral condyle of a plastic tibial model was performed after corrective osteotomy with simulated bone grafting and fixation using three methods, until a PLF deformation of 5 mm or damage (destruction) of the structure was achieved. Descriptive and comparative statistical methods were applied to the data obtained. Results. The mechanical study revealed that the original method yielded the highest strength values, with an average value of 1562 N (max — 1812 N; min — 1406 N) at an average deformation of 10.16 mm. This was comparable to the previous method. The volar plate yielded an average strength of 1182 N (max — 1285 N; min — 1091 N) at an average deformation of 10.56 mm, while the lateral condylar plate yielded slightly lower average values, at 1155 N (max — 1366 N; min — 893 N) at an average deformation of 9.12 mm. Conclusion.A mechanical study showed that the axial stiffness of the original tibial plateau fracture treatment, without the use of traditional plates, was comparable to that of volar plate fixation for the radius and superior to that of a lateral condylar plate.