SDShubo Dai

Shubo Dai

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Shubo Dai has a total of 11 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Blast Resistance of RC Slabs Strengthened with Concrete-Based Protective Layers Under Contact Explosion

    by Meili Meng, Shubo Dai, Jinlei Zheng, Ran Song, Kelei Cao, Changhui Zhang

    This study investigates the blast-protective performance of RC slab strengthened on the blast face with various concrete protective layers under contact-detonation loading. The research focuses on analyzing shock wave propagation characteristics, peak pressures at measurement points, energy absorption capacities of the protective layers, the development of damage, and the governing failure mechanisms of the RC slab. The protective layers used for structural reinforcement include Steel Fiber-Reinforced Cellular Concrete (SFR-CC), Asphalt Concrete (AC), Rubberized Concrete (RBC), and Foamed Concrete (FC). Among these, the maximum support rotation angle of the structure strengthened with the SFR-CC concrete layer (T-1) is 0.20°, indicating significantly less damage and deformation compared to other protective schemes. Based on the damage coefficient calculated from the remaining sectional moment of inertia of the protected RC slabs, the destruction grades of the structures at different concrete protective schemes were classified. Among these, the SFR-CC layer exhibits the most effective attenuation of shock wave peak pressure. Additionally, the maximum support rotation angle of the structure strengthened with the SFR-CC concrete layer is 0.20°, indicating significantly less damage and deformation compared to other protective schemes. Damage grades were assigned according to a coefficient derived from the residual sectional moment of inertia of the protected RC slabs. The SFR-CC configuration (T-1) gives the lowest damage index, 0.178, approximately 64.5% below that of the NC scheme, and is classified as slight damage. In contrast to the severe damage sustained by the protected RC slabs strengthened with the NC concrete scheme, those strengthened with the AC, RBC, and FC protective layer schemes exhibit only a moderate damage grade. Empirical formulas predicting the damage index of protected structures under the combined effects of varying blast charges and concrete layer thicknesses were further developed for rapid damage assessment.

  • Open Access

    Study on Damage Behavior and Anti-Explosion Performance of Steel Fiber-Reinforced Cellular Concrete Under Underwater Contact Explosion

    by Hu Huang, Shubo Dai, Kelei Cao, Changxing Tang, Xiancai Zhang, Changhui Zhang, Qingming Qiu

    To explore the damage mitigation mechanism of steel fiber-reinforced cellular concrete (SFR-CC) under underwater explosion loading, this study systematically analyzes two key variables: steel fiber volume fraction (0.5%, 1.0%, 1.5%, and 2.0%) and protective layer thickness (100 mm, 125 mm, 150 mm, 175 mm, and 200 mm). Based on underwater explosion numerical simulation, the influences of different variable combinations on damage evolution process, structural failure characteristics, dynamic mechanical response behavior, and energy dissipation capacity are investigated. The research results reveal that SFR-CC can effectively mitigate the energy of explosion shock waves. Both the steel fiber volume fraction and protective layer thickness exert significant influences on its underwater anti-explosion performance. The SAP20S15 protective layer exhibits excellent underwater protection performance. Under this specific engineering configuration, it achieves a remarkable attenuation of shock wave pressure acting on the protected structure. Increasing the thickness of the protective layer can substantially enhance its energy absorption capacity and markedly reduce the shock wave energy imposed on the protected structure. In addition, the energy dissipation sharing ratio, structural spalling angle, and peak velocity vector sum (PVS) were employed to conduct a systematic evaluation on the protective performance of the structure under various protective schemes. When the volume fraction of steel fibers is 1.5%, the energy dissipation ratio of the protective layer accounts for 80.49%, with the corresponding structural spalling angle and PVS of the protected plate being 59.5° and 21.4 m/s, respectively. When the protective layer thickness increases to 200 mm, the energy dissipation sharing rate rises by 54.8%, while the spalling angle and PVS of the RC slab decrease by 33.1% and 33.6%, respectively. This further verifies the superior underwater protection performance of the SAP20S15 protective layer under the same parametric conditions. Prediction curves for the damage grade of protected structures with different steel fiber volume fractions and protective layer thicknesses were established. The predicted values of the curves are in good agreement with the numerical simulation results, which can provide a theoretical reference for the rapid evaluation of the underwater anti-explosion performance of SFR-CC protective layers. The research findings can offer theoretical support for the engineering application of SFR-CC protective layers under identical parameter conditions in underwater explosion scenarios.