Umit Ali Karabag
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Umit Ali Karabag has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Eren Akin
Department of Orthopaedics and Traumatology, Faculty of Medicine Dokuz Eylul University Izmir Turkey
3 shared publications - Onur Hapa
Department of Orthopedics, Dokuz Eylül University Faculty of Medicine, Izmir, Turkey
3 shared publications - Selahaddin Aydemir
Department of Orthopaedics and Traumatology, Dokuz Eylul University, Izmir, Turkey
3 shared publications - Mazen Mohamed Ibrahim
Department of Orthopaedics and Traumatology, Faculty of Medicine, Helwan University, Cairo, Egypt; Orthopedic Consultant, Steadman Clinic, Vail, Colorado, USA
2 shared publications Cagri Havitcioglu
Department of Orthopedics and Traumatology, Ankara Etlik City Hospital, Ankara, Türkiye
1 shared publication- Cihangir Turemis
Department of Orthopaedics and Traumatology, Çeşme Alper Çizgenakat State Hospital, 35930 İzmir, Turkey
1 shared publication
Latest Publications
- Open Access
- 22 June 2026
- Published by SAGE Publications in Orthopaedic Journal of Sports Medicine
- Vol. 14 (6)
Graft Height and Labral Integrity as Key Determinants of Suction Seal Restoration in Hip Labral Augmentation: Findings From an Ovine Model
Background: The acetabular labrum plays a critical role in maintaining the hip suction seal, joint stability, and load distribution. When primary repair is not feasible, augmentation is preferred if the chondrolabral junction can be preserved, whereas reconstruction is performed when it cannot. However, biomechanical studies evaluating the effects of graft geometry and labral preservation strategies on suction seal restoration remain limited. Hypothesis/Purpose: It was hypothesized that augmentation using an extended graft combined with partial labral preservation would restore femoroacetabular suction seal strength more effectively than standard reconstruction after labrum excision. This study compared the biomechanical outcomes of different graft labral height and preservation width configurations in an ovine hip model. Study Design: Controlled laboratory study. Methods: A total of 48 fresh-frozen ovine hemipelvises were randomized into 6 groups (n = 8) according to labral preservation width, excision pattern, and graft radial height. Autologous extensor tendon grafts with standard or extended labral height were fixed to standardized segmental defects using suture anchors. The suction seal force was defined as the linear distraction force required to disrupt the femoroacetabular seal and measured in intact, excised, and reconstructed states. Restoration was defined as deviation from the intact condition and improvement relative to the excised state. Intergroup comparisons were performed using nonparametric tests with Bonferroni correction ( P < .003). Results: The configuration combining one-third native labral preservation with an extended graft demonstrated the smallest deviation from the intact condition (3.8 N) and the greatest improvement relative to the excised state (18 N), showing significant superiority compared with the total excision plus standard graft construct ( P ≤ .002). The configuration involving one-half labral preservation with a standard graft did not differ significantly from the extended graft group in terms of improvement ( P = .115) and exhibited a relatively small deviation from the intact condition (6.6 N). Rim trimming performed within anatomical boundaries did not compromise suction seal integrity. Conclusion/Clinical Relevance: Partial labral preservation combined with increased graft labral height provided the most favorable biomechanical restoration of femoroacetabular suction seal strength.
- 22 June 2026
- Published by SAGE Publications in Orthopaedic Journal of Sports Medicine
- Vol. 14 (6)
Open AccessGraft Height and Labral Integrity as Key Determinants of Suction Seal Restoration in Hip Labral Augmentation: Findings From an Ovine Model
Background: The acetabular labrum plays a critical role in maintaining the hip suction seal, joint stability, and load distribution. When primary repair is not feasible, augmentation is preferred if the chondrolabral junction can be preserved, whereas reconstruction is performed when it cannot. However, biomechanical studies evaluating the effects of graft geometry and labral preservation strategies on suction seal restoration remain limited. Hypothesis/Purpose: It was hypothesized that augmentation using an extended graft combined with partial labral preservation would restore femoroacetabular suction seal strength more effectively than standard reconstruction after labrum excision. This study compared the biomechanical outcomes of different graft labral height and preservation width configurations in an ovine hip model. Study Design: Controlled laboratory study. Methods: A total of 48 fresh-frozen ovine hemipelvises were randomized into 6 groups (n = 8) according to labral preservation width, excision pattern, and graft radial height. Autologous extensor tendon grafts with standard or extended labral height were fixed to standardized segmental defects using suture anchors. The suction seal force was defined as the linear distraction force required to disrupt the femoroacetabular seal and measured in intact, excised, and reconstructed states. Restoration was defined as deviation from the intact condition and improvement relative to the excised state. Intergroup comparisons were performed using nonparametric tests with Bonferroni correction ( P < .003). Results: The configuration combining one-third native labral preservation with an extended graft demonstrated the smallest deviation from the intact condition (3.8 N) and the greatest improvement relative to the excised state (18 N), showing significant superiority compared with the total excision plus standard graft construct ( P ≤ .002). The configuration involving one-half labral preservation with a standard graft did not differ significantly from the extended graft group in terms of improvement ( P = .115) and exhibited a relatively small deviation from the intact condition (6.6 N). Rim trimming performed within anatomical boundaries did not compromise suction seal integrity. Conclusion/Clinical Relevance: Partial labral preservation combined with increased graft labral height provided the most favorable biomechanical restoration of femoroacetabular suction seal strength.
- 13 May 2026
- Published by SAGE Publications in The American Journal of Sports Medicine
- Vol. 54 (8) , 1954-1960
Rat Model of Gluteus Medius Tendon Tear: Biomechanical and Histological Effects of Autologous Fascia Lata Augmentation
Background: Primary repair of full-thickness gluteus medius tears is challenging, particularly in retracted tears with poor tissue quality. Augmentation with autologous fascia lata may enhance repair strength and biologic healing. Purpose: To establish a gluteus medius tear detachment model in rats and to evaluate whether acute repair augmented with autologous fascia lata results in higher failure load and improved tendon-bone interface organization as compared with primary repair. Study Design: Controlled laboratory study. Methods: Forty adult female Sprague-Dawley rats were randomly assigned to 4 groups: intact control (group C), unrepaired tear (group 1), primary repair (group 2), and augmented repair with autologous fascia lata (group 3) (n = 6 for biomechanical testing, n = 4 for histological analysis per group). In groups 1 to 3, the gluteus medius tendon was detached from the greater trochanter. Group 1 underwent no repair. In groups 2 and 3, repair was performed acutely during the index procedure immediately after tendon detachment, using intraosseous tunnels and 5-0 Prolene sutures; in group 3, an autologous fascia lata graft was incorporated as an onlay augmentation. At 4 weeks, animals were euthanized for biomechanical and histological evaluation. Results: All tendons failed at the tendon-bone interface. Failure load was lower in group 1 (mean ± SD, 15 ± 6 N; P = .01) and group 2 (20 ± 4 N; P = .03) than in group C (29 ± 7 N), while group 3 (30 ± 7 N) did not differ from group C ( P = .60). Group 3 had higher strength than groups 2 ( P = .01) and 1 ( P = .004). Histological scores were lowest in group 1 (3 ± 0.5) as compared with group C (8 ± 1; P = .01), group 2 (12 ± 2; P < .001), and group 3 (11 ± 1; P = .001), with no difference among groups C, 2, and 3 ( P > .05). Conclusion: In a rat gluteus medius tendon detachment model, unrepaired detachment resulted in inferior biomechanical strength and histological healing at 4 weeks. Augmentation with autologous fascia lata improved biomechanical strength as compared with primary repair. Clinical Relevance: This rat model may be useful for preclinical evaluation of repair strategies for gluteus medius tears. Autologous fascia lata augmentation may offer biomechanical advantages over primary repair alone.
- 13 May 2026
- Published by SAGE Publications in The American Journal of Sports Medicine
- Vol. 54 (8) , 1954-1960
Rat Model of Gluteus Medius Tendon Tear: Biomechanical and Histological Effects of Autologous Fascia Lata Augmentation
Background: Primary repair of full-thickness gluteus medius tears is challenging, particularly in retracted tears with poor tissue quality. Augmentation with autologous fascia lata may enhance repair strength and biologic healing. Purpose: To establish a gluteus medius tear detachment model in rats and to evaluate whether acute repair augmented with autologous fascia lata results in higher failure load and improved tendon-bone interface organization as compared with primary repair. Study Design: Controlled laboratory study. Methods: Forty adult female Sprague-Dawley rats were randomly assigned to 4 groups: intact control (group C), unrepaired tear (group 1), primary repair (group 2), and augmented repair with autologous fascia lata (group 3) (n = 6 for biomechanical testing, n = 4 for histological analysis per group). In groups 1 to 3, the gluteus medius tendon was detached from the greater trochanter. Group 1 underwent no repair. In groups 2 and 3, repair was performed acutely during the index procedure immediately after tendon detachment, using intraosseous tunnels and 5-0 Prolene sutures; in group 3, an autologous fascia lata graft was incorporated as an onlay augmentation. At 4 weeks, animals were euthanized for biomechanical and histological evaluation. Results: All tendons failed at the tendon-bone interface. Failure load was lower in group 1 (mean ± SD, 15 ± 6 N; P = .01) and group 2 (20 ± 4 N; P = .03) than in group C (29 ± 7 N), while group 3 (30 ± 7 N) did not differ from group C ( P = .60). Group 3 had higher strength than groups 2 ( P = .01) and 1 ( P = .004). Histological scores were lowest in group 1 (3 ± 0.5) as compared with group C (8 ± 1; P = .01), group 2 (12 ± 2; P < .001), and group 3 (11 ± 1; P = .001), with no difference among groups C, 2, and 3 ( P > .05). Conclusion: In a rat gluteus medius tendon detachment model, unrepaired detachment resulted in inferior biomechanical strength and histological healing at 4 weeks. Augmentation with autologous fascia lata improved biomechanical strength as compared with primary repair. Clinical Relevance: This rat model may be useful for preclinical evaluation of repair strategies for gluteus medius tears. Autologous fascia lata augmentation may offer biomechanical advantages over primary repair alone.
- Open Access
- 5 May 2026
- Published by Oxford University Press (OUP) in Journal of Hip Preservation Surgery
Is the transverse screw really necessary? Biomechanical comparison of fixation strategies in periasetabular osteotomy
This study aims to compare the biomechanical stability of different screw and plate configurations used in the fixation of acetabular fragments after periacetabular osteotomy (PAO). A total of 42 synthetic hemipelvis models were categorized into six fixation groups: three iliac screws (3 V), four iliac screws (4 V), three screws + lateral compression (LC) screw (3 V + LC), locking three-screw plate (3P), plate + LC screw (3P + LC), and eight-screw plate (4P). All samples were evaluated for stiffness under a constant load of 700 N and for stiffness under maximum load. The greatest failure load was observed in the 3 V group (1249.4 N), whereas the 3P group demonstrated the lowest (658.5 N). In terms of maximum force, both the 3 V and 4 V groups were significantly superior to the 3P (P = .003 and P = .018, respectively) and 3P + LC (P = .006 and P = .021, respectively) groups. Although the 4P configuration showed the highest fracture stiffness (155.1 N/mm), this did not differ significantly among groups. Stiffness at a constant load of 700 N, the 3 V and 3 V + LC groups demonstrated higher stiffness than the 3P and 3P + LC groups, with comparisons to the 3P group approaching statistical significance (P = .064 and P = .063, respectively). Traditional iliac screw structures (especially 3 V and 4 V) provide effective fixation in terms of load-bearing and stiffness, while plate-based systems require a high number of screws and optimal placement to provide adequate stability. Although the LC screw increases stiffness, it provides only a limited contribution to breaking strength.
- 5 May 2026
- Published by Oxford University Press (OUP) in Journal of Hip Preservation Surgery
Open AccessIs the transverse screw really necessary? Biomechanical comparison of fixation strategies in periasetabular osteotomy
This study aims to compare the biomechanical stability of different screw and plate configurations used in the fixation of acetabular fragments after periacetabular osteotomy (PAO). A total of 42 synthetic hemipelvis models were categorized into six fixation groups: three iliac screws (3 V), four iliac screws (4 V), three screws + lateral compression (LC) screw (3 V + LC), locking three-screw plate (3P), plate + LC screw (3P + LC), and eight-screw plate (4P). All samples were evaluated for stiffness under a constant load of 700 N and for stiffness under maximum load. The greatest failure load was observed in the 3 V group (1249.4 N), whereas the 3P group demonstrated the lowest (658.5 N). In terms of maximum force, both the 3 V and 4 V groups were significantly superior to the 3P (P = .003 and P = .018, respectively) and 3P + LC (P = .006 and P = .021, respectively) groups. Although the 4P configuration showed the highest fracture stiffness (155.1 N/mm), this did not differ significantly among groups. Stiffness at a constant load of 700 N, the 3 V and 3 V + LC groups demonstrated higher stiffness than the 3P and 3P + LC groups, with comparisons to the 3P group approaching statistical significance (P = .064 and P = .063, respectively). Traditional iliac screw structures (especially 3 V and 4 V) provide effective fixation in terms of load-bearing and stiffness, while plate-based systems require a high number of screws and optimal placement to provide adequate stability. Although the LC screw increases stiffness, it provides only a limited contribution to breaking strength.