Takuto Hatakeyama
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Takuto Hatakeyama has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Daisuke Nakashima
Department of Orthopaedic Surgery Keio University School of Medicine Tokyo Japan
1 shared publication - Katsuhiro Mikami
Kindai University
1 shared publication - Mitsutaka Nemoto
Kindai University
1 shared publication Shogo Hashimoto
Graduate School of Biology-Oriented Science and Technology, Kindai University, 930 Nishi-mitani, Kinokawa, Wakayama 649-6493, Japan
1 shared publication- Takashi Nagaoka
Kindai University
1 shared publication - Takeo Nagura
Department of Clinical Biomechanics, Keio University School of Medicine, Tokyo, Japan
1 shared publication
Latest Publications
- 20 May 2026
- Published by Fuji Technology Press Ltd. in Journal of Advanced Computational Intelligence and Intelligent Informatics
- Vol. 30 (3) , 718-726
Evaluation Using AI-Based Approach of Pedicle Screw Stability Using Laser Resonance Frequency Analysis Prior to Surgical Insertion
In orthopedics, assessing the initial stability of pedicle screws is crucial for preventing failure after implantation. Traditional methods for determining stability are applicable only to post-screw insertion, complicating recovery in cases of inadequate strength. This study aimed to predict implant stability at the tapping stage prior to screw placement. Artificial bones with five distinct densities were utilized to measure tapping and screw insertion torques, facilitating a statistical evaluation of bone density and placement strength. A laser resonance frequency analysis (L-RFA) was conducted to obtain the vibration frequency spectra of the tap. Furthermore, linear approximation and support vector regression (SVR) were employed, utilizing spectral data and a 95% confidence interval to predict bone density. Significant differences in tapping and screw insertion torques were observed relative to bone density ( p R 2 of 0.843. The acquisition of bone density data at the tapping stage enables the prediction of expected screw stability. Bone density prediction using L-RFA has the potential to provide stability indicators prior to pedicle screw insertion.
- 20 May 2026
- Published by Fuji Technology Press Ltd. in Journal of Advanced Computational Intelligence and Intelligent Informatics
- Vol. 30 (3) , 718-726
Evaluation Using AI-Based Approach of Pedicle Screw Stability Using Laser Resonance Frequency Analysis Prior to Surgical Insertion
In orthopedics, assessing the initial stability of pedicle screws is crucial for preventing failure after implantation. Traditional methods for determining stability are applicable only to post-screw insertion, complicating recovery in cases of inadequate strength. This study aimed to predict implant stability at the tapping stage prior to screw placement. Artificial bones with five distinct densities were utilized to measure tapping and screw insertion torques, facilitating a statistical evaluation of bone density and placement strength. A laser resonance frequency analysis (L-RFA) was conducted to obtain the vibration frequency spectra of the tap. Furthermore, linear approximation and support vector regression (SVR) were employed, utilizing spectral data and a 95% confidence interval to predict bone density. Significant differences in tapping and screw insertion torques were observed relative to bone density ( p R 2 of 0.843. The acquisition of bone density data at the tapping stage enables the prediction of expected screw stability. Bone density prediction using L-RFA has the potential to provide stability indicators prior to pedicle screw insertion.