Shiyi Shao
Research Subjects
Research Interests
Shiyi Shao has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
- Hui Zhao
College of Intelligent Robotics and Advanced Manufacturing, Fudan University, Shanghai 200433, China
2 shared publications - Rongrong Zhang
College of Intelligent Robotics and Advanced Manufacturing, Fudan University, Shanghai 200433, China
2 shared publications - Atif Iqbal
Department of Electrical Engineering, Qatar University, Doha, Qatar
1 shared publication - Cheng Wang
School of Automation, Nanjing University of Science and Technology, Nanjing 210094, China
1 shared publication - Dachuan Chen
Department of Electrical Engineering, Shanghai Jiao Tong University, Shanghai, China
1 shared publication - Jian Qiu
College of Intelligent Robotics and Advanced Manufacturing, Fudan University, Shanghai 200433, China
1 shared publication
Latest Publications
- Open Access
- 13 November 2026
- Published by MDPI AG in Electronics
- Vol. 15 (22) , 5283
An H-Bridge-Based Battery ACIR Measurement System with Energy Recovery
Conventional battery alternating current internal resistance (ACIR) measurement faces challenges in generating adjustable high-current excitation with low energy dissipation and accurately acquiring weak alternating current (AC) voltage responses. This paper proposes an H-bridge-based battery ACIR measurement system with energy recovery. The battery under test directly supplies the excitation energy, enabling bidirectional energy transfer through the H-bridge and an energy-storage inductor. Fixed-frequency phase-shift modulation generates amplitude-adjustable bidirectional test currents at 1 kHz. An active direct current (DC) offset-cancelation sensing architecture improves analog-to-digital converter (ADC) input-range utilization for millivolt-level AC voltage responses, while a single-bin discrete Fourier transform (DFT) extracts the 1 kHz fundamental components for ACIR calculation. At measured peak test currents of 20, 100, and 400 mA, the charge return ratios were 8.53%, 9.81%, and 12.49%, respectively. Under the constant-terminal-voltage approximation, these values also estimate the fraction of energy drawn from the battery that was returned to it during the same excitation cycle. During 15 min repeated measurements, the proposed system exhibited lower apparent temperatures than the comparison instruments under the respective test conditions, with no detectable change in battery open-circuit voltage at the reported resolution. For the same conditioned signal, the 1 kHz fundamental voltage amplitude obtained from the ADC samples was 2.34% lower than the oscilloscope result. After channel calibration, the proposed system measured the 1 kHz ACIR of seven lithium-ion cells using the 20 and 100 mA excitation settings. Across the seven cells, the maximum and mean absolute relative deviations were 3.50% and 1.60%, respectively, relative to the VICTOR 3540, and 2.65% and 1.26%, respectively, relative to the FNIRSI HRM-10.
- 13 November 2026
- Published by MDPI AG in Electronics
- Vol. 15 (22) , 5283
Open AccessAn H-Bridge-Based Battery ACIR Measurement System with Energy Recovery
Conventional battery alternating current internal resistance (ACIR) measurement faces challenges in generating adjustable high-current excitation with low energy dissipation and accurately acquiring weak alternating current (AC) voltage responses. This paper proposes an H-bridge-based battery ACIR measurement system with energy recovery. The battery under test directly supplies the excitation energy, enabling bidirectional energy transfer through the H-bridge and an energy-storage inductor. Fixed-frequency phase-shift modulation generates amplitude-adjustable bidirectional test currents at 1 kHz. An active direct current (DC) offset-cancelation sensing architecture improves analog-to-digital converter (ADC) input-range utilization for millivolt-level AC voltage responses, while a single-bin discrete Fourier transform (DFT) extracts the 1 kHz fundamental components for ACIR calculation. At measured peak test currents of 20, 100, and 400 mA, the charge return ratios were 8.53%, 9.81%, and 12.49%, respectively. Under the constant-terminal-voltage approximation, these values also estimate the fraction of energy drawn from the battery that was returned to it during the same excitation cycle. During 15 min repeated measurements, the proposed system exhibited lower apparent temperatures than the comparison instruments under the respective test conditions, with no detectable change in battery open-circuit voltage at the reported resolution. For the same conditioned signal, the 1 kHz fundamental voltage amplitude obtained from the ADC samples was 2.34% lower than the oscilloscope result. After channel calibration, the proposed system measured the 1 kHz ACIR of seven lithium-ion cells using the 20 and 100 mA excitation settings. Across the seven cells, the maximum and mean absolute relative deviations were 3.50% and 1.60%, respectively, relative to the VICTOR 3540, and 2.65% and 1.26%, respectively, relative to the FNIRSI HRM-10.
- Open Access
- 27 May 2026
- Published by MDPI AG in Electronics
- Vol. 15 (11) , 2329
Using Eddy Current Effect to Mitigate Near-Field Magnetic Radiation in SiC-MOSFETs Half-Bridge
SiC MOSFETs suffer from severe EMI issues due to their high dv/dt and di/dt values as well as the reduced coupling length resulting from their compact design. Conventional magnetic shielding suffers from three major limitations: susceptibility to magnetic saturation, restrictions at high frequencies, and extra parasitic inductance introduced by the shielding material itself. This paper proposes a method that uses eddy currents to mitigate the near-field magnetic radiation. By wrapping the system in an external copper layer without affecting system layout or wiring, external radiation is reduced by 10 times, removing the possibility of magnetic saturation, and reducing parasitic inductance by 10 percent. Compared to traditional magnetic shielding, this solution is cost-effective, and offers enhanced reliability and performance.
- 27 May 2026
- Published by MDPI AG in Electronics
- Vol. 15 (11) , 2329
Open AccessUsing Eddy Current Effect to Mitigate Near-Field Magnetic Radiation in SiC-MOSFETs Half-Bridge
SiC MOSFETs suffer from severe EMI issues due to their high dv/dt and di/dt values as well as the reduced coupling length resulting from their compact design. Conventional magnetic shielding suffers from three major limitations: susceptibility to magnetic saturation, restrictions at high frequencies, and extra parasitic inductance introduced by the shielding material itself. This paper proposes a method that uses eddy currents to mitigate the near-field magnetic radiation. By wrapping the system in an external copper layer without affecting system layout or wiring, external radiation is reduced by 10 times, removing the possibility of magnetic saturation, and reducing parasitic inductance by 10 percent. Compared to traditional magnetic shielding, this solution is cost-effective, and offers enhanced reliability and performance.