Ali Bebboukha
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Ali Bebboukha has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
- Redha Meneceur
UDERZA Unit, Department of Mechanical Engineering, Faculty of Technology, University of El Oued, El Oued, Algeria
2 shared publications A. Hechifa
1 shared publication- Abdelaziz Lakehal
University of Souk Ahras
1 shared publication - Abdelmoumene Hechifa
Department of Mechanical Engineering, LGMM Laboratory, University of 20 August 1955, Skikda, Algeria
1 shared publication - Ahmed Elsanabary
Interdisciplinary Research Center for Sustainable Energy Systems (IRC-SES), King Fahd University of Petroleum and Minerals (KFUPM), Dhahran, Saudi Arabia
1 shared publication - Ali Boukhari1 shared publication
Latest Publications
- Open Access
- 25 June 2026
- Published by Elsevier in Energy Reports
- Vol. 16
ANN-enhanced deadbeat predictive current controller for robust voltage source inverter performance
- 25 June 2026
- Published by Elsevier in Energy Reports
- Vol. 16
Open AccessANN-enhanced deadbeat predictive current controller for robust voltage source inverter performance
- 27 May 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. PP (10709878) , 1
Enhanced Circle Method for Discriminating Incipient Faults in Power Transformers Using Dissolved Gas Analysis
Power transformers are essential components in electrical power systems, ensuring the continuous transmission and distribution of electricity. Dissolved Gas Analysis (DGA) has become a widely accepted method for monitoring the condition of transformers and detecting incipient faults. Among the various DGA methods, graphical techniques have gained significant popularity in recent years. In this study, an Improved Circle Method is proposed as an enhanced extension of the Circle 1 and Circle 2 methods to address the limitations of traditional DGA methods in distinguishing overlapping fault types. The method employs a sigmoid activation function to control the convergence and divergence distances between fault samples, significantly improving the separation of electrical and thermal faults. By utilizing Gray Wolf Optimization (GWO), optimal angles are determined for the best fault separation. Experimental validation using the IEC TC10 database demonstrated that the Improved Circle Method achieves an overall accuracy of 79.49%, which can be considered an improvement over both Circle 1 and Circle 2 methods. The results confirm that the proposed method serves as a reliable alternative to other conventional graphical techniques.
- 27 May 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. PP (10709878) , 1
Enhanced Circle Method for Discriminating Incipient Faults in Power Transformers Using Dissolved Gas Analysis
Power transformers are essential components in electrical power systems, ensuring the continuous transmission and distribution of electricity. Dissolved Gas Analysis (DGA) has become a widely accepted method for monitoring the condition of transformers and detecting incipient faults. Among the various DGA methods, graphical techniques have gained significant popularity in recent years. In this study, an Improved Circle Method is proposed as an enhanced extension of the Circle 1 and Circle 2 methods to address the limitations of traditional DGA methods in distinguishing overlapping fault types. The method employs a sigmoid activation function to control the convergence and divergence distances between fault samples, significantly improving the separation of electrical and thermal faults. By utilizing Gray Wolf Optimization (GWO), optimal angles are determined for the best fault separation. Experimental validation using the IEC TC10 database demonstrated that the Improved Circle Method achieves an overall accuracy of 79.49%, which can be considered an improvement over both Circle 1 and Circle 2 methods. The results confirm that the proposed method serves as a reliable alternative to other conventional graphical techniques.