Yuanbiao Wang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Yuanbiao Wang has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
- Chi Ma
School of Mechanical and Electrical Engineering, Shaanxi University of Science and Technology, Xi’an 710021, China
1 shared publication - Gongchang Ren
Shannxi University of Science & Technology
1 shared publication - Haitao Li
School of Mechanical and Electrical Engineering, Shaanxi University of Science and Technology, Xi’an 710021, China
1 shared publication - Jiangong Sun
School of Mechanical and Electrical Engineering, Shaanxi University of Science and Technology, Xi’an 710021, China
1 shared publication - Jiaxuan Yang
School of Mechanical and Electrical Engineering, Shaanxi University of Science and Technology, Xi’an 710021, China
1 shared publication - Jie Li
School of Mechanical and Electrical Engineering, Shaanxi University of Science and Technology, Xi’an 710021, China
1 shared publication
Latest Publications
- Open Access
- 20 August 2026
- Published by MDPI AG in Electronics
- Vol. 15 (16) , 3742
High-Precision Detection of Leather Creases via Dynamic, Cross-Calibrated, and Edge-Enhanced YOLOv8n-Pose
Residual creases generated during the leather spreading process exhibit highly variable morphologies and irregular feature distributions, causing significant challenges for feature extraction and leading to low localization accuracy. To address these issues, this paper proposes the Dynamic, Cross-Calibrated, and Edge-Enhanced YOLOv8n-Pose (DCE-YOLOv8n-Pose) algorithm. Instead of providing regional approximations, this framework outputs precise spatial coordinates for robotic grasping by integrating three synergistic components in a progressive network flow. First, dynamic snake convolution adaptively perceives the continuous geometric features of elongated creases; subsequently, an efficient multi-scale attention mechanism provides cross-dimensional weight calibration to suppress highly homochromatic background interference and correct spatial misalignments; finally, an edge-enhanced content-aware reassembly of features module preserves high-frequency gradients and prevents feature fracturing during multi-scale fusion. For comprehensive evaluation, a dataset comprising 700 original laboratory images was constructed. To prevent data leakage, the dataset was partitioned into training and validation sets based on individual leather specimens, ensuring that images of the same leather piece do not appear in both sets. Additionally, an independent test set of 500 images collected from an actual processing plant was designed for industrial validation. Experimental results indicate that, at an Intersection over Union (IoU) threshold of 0.5, the DCE-YOLOv8n-Pose model achieves a bounding box mean average precision (mAP@0.5) of 91.8% and a keypoint mAP@0.5 of 85.1%, with a keypoint precision of 87.9%. The computational load is maintained at 9.2 GFLOPs, alongside an inference speed of 114.3 FPS. Furthermore, consistent convergence across four independent training runs substantiates the model’s reliability in reducing missed detection rates and localization deviations. In conclusion, the proposed algorithm demonstrates practical applicability for the visual guidance of automated leather spreading equipment by balancing detection precision and inference speed, thereby offering an effective coordinate reference for subsequent robotic stretching operations.
- 20 August 2026
- Published by MDPI AG in Electronics
- Vol. 15 (16) , 3742
Open AccessHigh-Precision Detection of Leather Creases via Dynamic, Cross-Calibrated, and Edge-Enhanced YOLOv8n-Pose
Residual creases generated during the leather spreading process exhibit highly variable morphologies and irregular feature distributions, causing significant challenges for feature extraction and leading to low localization accuracy. To address these issues, this paper proposes the Dynamic, Cross-Calibrated, and Edge-Enhanced YOLOv8n-Pose (DCE-YOLOv8n-Pose) algorithm. Instead of providing regional approximations, this framework outputs precise spatial coordinates for robotic grasping by integrating three synergistic components in a progressive network flow. First, dynamic snake convolution adaptively perceives the continuous geometric features of elongated creases; subsequently, an efficient multi-scale attention mechanism provides cross-dimensional weight calibration to suppress highly homochromatic background interference and correct spatial misalignments; finally, an edge-enhanced content-aware reassembly of features module preserves high-frequency gradients and prevents feature fracturing during multi-scale fusion. For comprehensive evaluation, a dataset comprising 700 original laboratory images was constructed. To prevent data leakage, the dataset was partitioned into training and validation sets based on individual leather specimens, ensuring that images of the same leather piece do not appear in both sets. Additionally, an independent test set of 500 images collected from an actual processing plant was designed for industrial validation. Experimental results indicate that, at an Intersection over Union (IoU) threshold of 0.5, the DCE-YOLOv8n-Pose model achieves a bounding box mean average precision (mAP@0.5) of 91.8% and a keypoint mAP@0.5 of 85.1%, with a keypoint precision of 87.9%. The computational load is maintained at 9.2 GFLOPs, alongside an inference speed of 114.3 FPS. Furthermore, consistent convergence across four independent training runs substantiates the model’s reliability in reducing missed detection rates and localization deviations. In conclusion, the proposed algorithm demonstrates practical applicability for the visual guidance of automated leather spreading equipment by balancing detection precision and inference speed, thereby offering an effective coordinate reference for subsequent robotic stretching operations.
- Open Access
Principle and Method of Base Station Calibration Based on a Physical Standard for Multi-Station Laser Tracking Measurement
In the measurement of volumetric errors in CNC machine tools using multi-station laser tracking technology, the coordinate calibration accuracy of external measurement base stations is a key factor determining the system’s final accuracy. Traditional calibration approaches typically use the commanded positions of the machine tool directly to inversely determine base station coordinates, which results in strong coupling between inherent geometric errors and base station parameters. Consequently, the measurement accuracy cannot be properly evaluated, and metrological traceability of the results remains difficult to achieve. To address this issue, this paper proposes a novel calibration principle based on an independent external physical standard and develops a base station calibrator independently. This device employs a precision turntable, G5-grade precision spheres, and electromagnet groups to construct an equivalent target with four feature points at the spindle end. Verified by a high-precision coordinate measuring machine (CMM), the maximum difference in repeated calibrations of the device is 1.4 µm, indicating its excellent positioning repeatability. The calibrator was further applied to measure the positioning errors of a CNC milling machine, and comparative experiments were performed with a Renishaw XL-80 laser interferometer. The results indicate that the error variation trends obtained from the two measurement principles are highly consistent. In both the X-axis and Y-axis directions, the maximum deviations of linear errors are controlled within 3.7 µm, while the maximum deviations of angular errors remain within 4.6 µrad. Furthermore, the reliability of the system data was confirmed through an uncertainty analysis. The external physical standard developed in this study ensures that base station calibration accuracy is not affected by the inherent errors of the machine tool, providing a novel and reliable scheme for high-precision calibration and metrological traceability of machine tool spatial errors.
Open AccessPrinciple and Method of Base Station Calibration Based on a Physical Standard for Multi-Station Laser Tracking Measurement
In the measurement of volumetric errors in CNC machine tools using multi-station laser tracking technology, the coordinate calibration accuracy of external measurement base stations is a key factor determining the system’s final accuracy. Traditional calibration approaches typically use the commanded positions of the machine tool directly to inversely determine base station coordinates, which results in strong coupling between inherent geometric errors and base station parameters. Consequently, the measurement accuracy cannot be properly evaluated, and metrological traceability of the results remains difficult to achieve. To address this issue, this paper proposes a novel calibration principle based on an independent external physical standard and develops a base station calibrator independently. This device employs a precision turntable, G5-grade precision spheres, and electromagnet groups to construct an equivalent target with four feature points at the spindle end. Verified by a high-precision coordinate measuring machine (CMM), the maximum difference in repeated calibrations of the device is 1.4 µm, indicating its excellent positioning repeatability. The calibrator was further applied to measure the positioning errors of a CNC milling machine, and comparative experiments were performed with a Renishaw XL-80 laser interferometer. The results indicate that the error variation trends obtained from the two measurement principles are highly consistent. In both the X-axis and Y-axis directions, the maximum deviations of linear errors are controlled within 3.7 µm, while the maximum deviations of angular errors remain within 4.6 µrad. Furthermore, the reliability of the system data was confirmed through an uncertainty analysis. The external physical standard developed in this study ensures that base station calibration accuracy is not affected by the inherent errors of the machine tool, providing a novel and reliable scheme for high-precision calibration and metrological traceability of machine tool spatial errors.