WSWeihao Su

Weihao Su

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Weihao Su has a total of 10 co-authors. Here are the top co-authors by number of shared publications:

  • Chi Ma

    School of Mechanical and Electrical Engineering, Shaanxi University of Science and Technology, Xi’an 710021, China

    1 shared publication
  • Haitao Li

    School of Mechanical and Electrical Engineering, Shaanxi University of Science and Technology, Xi’an 710021, China

    1 shared publication
  • Jie Li

    School of Mechanical and Electrical Engineering, Shaanxi University of Science and Technology, Xi’an 710021, China

    1 shared publication
  • Lijun Yang

    School of Mechanical and Electrical Engineering, Shaanxi University of Science and Technology, Xi’an 710021, China

    1 shared publication
  • Meng Zhang

    College of Mechanical and Electrical Engineering, Shaanxi University of Science & Technology, Xi’an 710021, People’s Republic of China

    1 shared publication
  • Yawen Wang

    School of Mechanical and Electrical Engineering, Shaanxi University of Science and Technology, Xi’an 710021, China

    1 shared publication

Latest Publications

  • Open Access

    Principle and Method of Base Station Calibration Based on a Physical Standard for Multi-Station Laser Tracking Measurement

    by Haitao Li, Yuanbiao Wang, Yawen Wang, Yunlong Yu, Zehao Wang, Weihao Su, Yehao Zhu, Lijun Yang, Chi Ma, Jie Li, et al.

    In the measurement of volumetric errors in CNC machine tools using multi-station laser tracking technology, the coordinate calibration accuracy of external measurement base stations is a key factor determining the system’s final accuracy. Traditional calibration approaches typically use the commanded positions of the machine tool directly to inversely determine base station coordinates, which results in strong coupling between inherent geometric errors and base station parameters. Consequently, the measurement accuracy cannot be properly evaluated, and metrological traceability of the results remains difficult to achieve. To address this issue, this paper proposes a novel calibration principle based on an independent external physical standard and develops a base station calibrator independently. This device employs a precision turntable, G5-grade precision spheres, and electromagnet groups to construct an equivalent target with four feature points at the spindle end. Verified by a high-precision coordinate measuring machine (CMM), the maximum difference in repeated calibrations of the device is 1.4 µm, indicating its excellent positioning repeatability. The calibrator was further applied to measure the positioning errors of a CNC milling machine, and comparative experiments were performed with a Renishaw XL-80 laser interferometer. The results indicate that the error variation trends obtained from the two measurement principles are highly consistent. In both the X-axis and Y-axis directions, the maximum deviations of linear errors are controlled within 3.7 µm, while the maximum deviations of angular errors remain within 4.6 µrad. Furthermore, the reliability of the system data was confirmed through an uncertainty analysis. The external physical standard developed in this study ensures that base station calibration accuracy is not affected by the inherent errors of the machine tool, providing a novel and reliable scheme for high-precision calibration and metrological traceability of machine tool spatial errors.