Harmonic Distortion and Distribution Transformer Thermal Risk in Low-Voltage Networks: Feeder Impedance Sensitivity for Sustainable Renewable Energy Integration
The increasing penetration of distributed energy resources (DERs) in low-voltage networks is central to the clean energy transition but introduces coupled challenges in voltage regulation, harmonic distortion, and distribution-transformer operation that impact grid sustainability and asset longevity. This paper isolates feeder impedance as a controlled variable and evaluates whether remote-network power-quality severity and transformer consequence follow the same sensitivity trend. A time-domain model used a factory-matched 200 kVA, 11 kV/420 V Dyn11 transformer with 40% DER connected at remote Node S3. The DER current contained prescribed fifth, seventh, eleventh, and thirteenth harmonics, while the LV feeder resistance and inductance were co-scaled from 0.5 to 2.0 pu. Across the DER-connected sweep, Node S3 line-to-line RMS voltage increased from 420.45 V to 428.95 V, and the voltage-rise magnitude increased from 3.03 V to 11.55 V. Selected-order Node S3 VTHD increased monotonically from 1.104% to 1.395%. Baseline-corrected harmonic transfer impedance also increased at every assessed harmonic, supporting a feeder-impedance-driven voltage-response mechanism. In contrast, transformer loading remained within 14.44–14.52%, total transformer loss within 350.26–350.93 W, hot-spot temperature within 38.229–38.246 °C, and common-baseline relative aging within 0.2863–0.2871. The results demonstrate that feeder weakness can materially increase remote-node voltage and harmonic sensitivity without producing a corresponding increase in transformer thermal severity. Network voltage response and transformer consequence should therefore be assessed as related but non-equivalent engineering domains. By separating power quality management from transformer thermal risk, distribution utilities can avoid premature asset replacement, enabling targeted, resource-efficient investments that support sustainable grid planning and long-term renewable integration (SDG 7 and SDG 9).
- 15 October 2026
- Published by MDPI AG in Sustainability
- Vol. 18 (20) , 10503
Open AccessHarmonic Distortion and Distribution Transformer Thermal Risk in Low-Voltage Networks: Feeder Impedance Sensitivity for Sustainable Renewable Energy Integration
The increasing penetration of distributed energy resources (DERs) in low-voltage networks is central to the clean energy transition but introduces coupled challenges in voltage regulation, harmonic distortion, and distribution-transformer operation that impact grid sustainability and asset longevity. This paper isolates feeder impedance as a controlled variable and evaluates whether remote-network power-quality severity and transformer consequence follow the same sensitivity trend. A time-domain model used a factory-matched 200 kVA, 11 kV/420 V Dyn11 transformer with 40% DER connected at remote Node S3. The DER current contained prescribed fifth, seventh, eleventh, and thirteenth harmonics, while the LV feeder resistance and inductance were co-scaled from 0.5 to 2.0 pu. Across the DER-connected sweep, Node S3 line-to-line RMS voltage increased from 420.45 V to 428.95 V, and the voltage-rise magnitude increased from 3.03 V to 11.55 V. Selected-order Node S3 VTHD increased monotonically from 1.104% to 1.395%. Baseline-corrected harmonic transfer impedance also increased at every assessed harmonic, supporting a feeder-impedance-driven voltage-response mechanism. In contrast, transformer loading remained within 14.44–14.52%, total transformer loss within 350.26–350.93 W, hot-spot temperature within 38.229–38.246 °C, and common-baseline relative aging within 0.2863–0.2871. The results demonstrate that feeder weakness can materially increase remote-node voltage and harmonic sensitivity without producing a corresponding increase in transformer thermal severity. Network voltage response and transformer consequence should therefore be assessed as related but non-equivalent engineering domains. By separating power quality management from transformer thermal risk, distribution utilities can avoid premature asset replacement, enabling targeted, resource-efficient investments that support sustainable grid planning and long-term renewable integration (SDG 7 and SDG 9).
- Open Access
- 28 May 2026
- Published by MDPI AG in Engineering Proceedings
- Vol. 140 (1) , 40
Assessment of Harmonic Distortion Compliance in South African Distribution Networks Under Increasing Penetration of Distributed Energy Resources
The increasing penetration of inverter-based distributed energy resources (DERs) within distribution networks has resulted in harmonic distortion risks that can affect transformer thermal loading, service life, and network hosting capacity. This study assesses harmonic behaviour under increasing DER penetration using a detailed MATLAB 2025b/Simulink model of the CIGRÉ low-voltage benchmark feeder, adapted to reflect representative network parameters and run at a 400 V point of common coupling (PCC). DER penetration is incrementally increased from 0% to 195% of feeder load, and for each penetration level the PCC currents and voltages are examined using FFT-based spectrum extraction. The short-circuit strength is first calculated (I_SC/I_L = 14.1), and harmonic current and voltage distortion thresholds are benchmarked against IEEE 519:2022 and NRS 048-2:2025 respectively. Results show that while DER inverters introduce increasing odd-order harmonics, mainly the 3rd, 5th, 7th and 11th, the feeder’s moderate short-circuit capacity suppresses PCC voltage distortion, keeping voltage THD below 3% across all scenarios. As the inverter-based DER penetration increases, so does the harmonic current distortion. At 180%, Total Demand Distortion (TDD) nears the IEEE limit of 5%.
- 28 May 2026
- Published by MDPI AG in Engineering Proceedings
- Vol. 140 (1) , 40
Open AccessAssessment of Harmonic Distortion Compliance in South African Distribution Networks Under Increasing Penetration of Distributed Energy Resources
The increasing penetration of inverter-based distributed energy resources (DERs) within distribution networks has resulted in harmonic distortion risks that can affect transformer thermal loading, service life, and network hosting capacity. This study assesses harmonic behaviour under increasing DER penetration using a detailed MATLAB 2025b/Simulink model of the CIGRÉ low-voltage benchmark feeder, adapted to reflect representative network parameters and run at a 400 V point of common coupling (PCC). DER penetration is incrementally increased from 0% to 195% of feeder load, and for each penetration level the PCC currents and voltages are examined using FFT-based spectrum extraction. The short-circuit strength is first calculated (I_SC/I_L = 14.1), and harmonic current and voltage distortion thresholds are benchmarked against IEEE 519:2022 and NRS 048-2:2025 respectively. Results show that while DER inverters introduce increasing odd-order harmonics, mainly the 3rd, 5th, 7th and 11th, the feeder’s moderate short-circuit capacity suppresses PCC voltage distortion, keeping voltage THD below 3% across all scenarios. As the inverter-based DER penetration increases, so does the harmonic current distortion. At 180%, Total Demand Distortion (TDD) nears the IEEE limit of 5%.