Fupeng Zhang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Fupeng Zhang has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Biao Wang
School of Architecture, Soochow University, Suzhou 215123, China
1 shared publication - Dong Yan
Architecture College, Nanyang Institute of Technology, Nanyang 473004, China
1 shared publication - Jingxin Zhao
Architecture College, Nanyang Institute of Technology, Nanyang 473004, China
1 shared publication Lei Shi
School of Architecture and Art, Central South University, Changsha, China
1 shared publication- Lei Shi
School of Architecture and Art, Central South University, Changsha 410075, China
1 shared publication - Meizhen Long
School of Architecture and Art, Central South University, Changsha 410075, China
1 shared publication
Latest Publications
- Open Access
- 11 November 2026
- Published by Springer Nature in Humanities and Social Sciences Communications
Embodiment of Tao in artifacts: a philosophical comparison of Chinese and Western perspectives on Changsha Kiln ware
- 11 November 2026
- Published by Springer Nature in Humanities and Social Sciences Communications
Open AccessEmbodiment of Tao in artifacts: a philosophical comparison of Chinese and Western perspectives on Changsha Kiln ware
- Open Access
Study on Summer Indoor Thermal Comfort and Thermal Adaptation of Resettlers Under Different Relocation Modes in the South-to-North Water Diversion Project
The South-to-North Water Diversion Project (SNWDP) in China involves a vast number of resettlers with far-reaching impacts. As a crucial carrier of resettlers’ daily lives, the indoor thermal comfort of resettlement housing directly affects their physical and mental health. However, existing empirical and field studies have paid limited attention to the thermal comfort and thermal adaptation of the resettlers. This study focuses on resettlers of the SNWDP, employing a combination of questionnaires and on-site measurements to analyze thermal benchmarks and thermal adaptation behavior data. The study introduces the concept of relative deprivation theory from social psychology, compares the correlations between vertical and horizontal deprivation and thermal perception across different relocation modes, and validates the predictive performance of commonly used thermal comfort models. The results show that as the relocation distance increases, the summer indoor thermal neutral temperature rises sequentially, and both the sensitivity to temperature changes and the width of the comfort zone also increase. Regarding thermal adaptation behaviors, the short-distance group primarily relies on passive adjustments such as using electric fans and reducing clothing, while the long-distance group significantly shifts toward active mechanical cooling like air conditioning. The sense of relative deprivation has a significant impact on the thermal comfort of medium- and long-distance resettlers, and its correlation even exceeds that of physical factors such as air temperature and black globe temperature. Among all groups, the ePMV and ePTS models modified by the expectancy factor exhibit the best predictive performance, with the smallest average deviation from the actual Thermal Sensation Vote (TSV), making them the optimal evaluation models for indoor thermal comfort of resettlers in the SNWDP. The findings provide theoretical guidance for creating healthy and comfortable indoor thermal environments in resettlement areas and for the sustainable development of subsequent phases of the SNWDP.
Open AccessStudy on Summer Indoor Thermal Comfort and Thermal Adaptation of Resettlers Under Different Relocation Modes in the South-to-North Water Diversion Project
The South-to-North Water Diversion Project (SNWDP) in China involves a vast number of resettlers with far-reaching impacts. As a crucial carrier of resettlers’ daily lives, the indoor thermal comfort of resettlement housing directly affects their physical and mental health. However, existing empirical and field studies have paid limited attention to the thermal comfort and thermal adaptation of the resettlers. This study focuses on resettlers of the SNWDP, employing a combination of questionnaires and on-site measurements to analyze thermal benchmarks and thermal adaptation behavior data. The study introduces the concept of relative deprivation theory from social psychology, compares the correlations between vertical and horizontal deprivation and thermal perception across different relocation modes, and validates the predictive performance of commonly used thermal comfort models. The results show that as the relocation distance increases, the summer indoor thermal neutral temperature rises sequentially, and both the sensitivity to temperature changes and the width of the comfort zone also increase. Regarding thermal adaptation behaviors, the short-distance group primarily relies on passive adjustments such as using electric fans and reducing clothing, while the long-distance group significantly shifts toward active mechanical cooling like air conditioning. The sense of relative deprivation has a significant impact on the thermal comfort of medium- and long-distance resettlers, and its correlation even exceeds that of physical factors such as air temperature and black globe temperature. Among all groups, the ePMV and ePTS models modified by the expectancy factor exhibit the best predictive performance, with the smallest average deviation from the actual Thermal Sensation Vote (TSV), making them the optimal evaluation models for indoor thermal comfort of resettlers in the SNWDP. The findings provide theoretical guidance for creating healthy and comfortable indoor thermal environments in resettlement areas and for the sustainable development of subsequent phases of the SNWDP.
- Open Access
A Study on Indoor Air Quality in Traditional Earthen Residences of Western Hunan: Field Survey and Passive Mitigation Strategies
In the western Hunan region, the fire pit serves as the primary space for heating, receiving guests, and sacrificial ceremonies. However, the prolonged use of wood as the main fuel for the fire pit poses a significant threat to indoor air quality and the health of residents. This study conducts field monitoring and evaluation of indoor air quality in traditional earthen residences in Western Hunan during winter. It employs software simulation to analyze the concentration of indoor pollutants in typical earthen dwellings. Three passive mitigation strategies—adjusting window size, installing interior partitions, and setting up passive smoke exhaust systems—are proposed, and their effectiveness is validated through simulation. The results indicate that the best air circulation performance occurs when the window sill height is between 0.9 and 1.5 m, and the window sill length is between 1.5 and 2.1 m. Installing partitions increases the average concentration of indoor pollutants in the fire pit and master bedroom areas by 2.33 and 3.05 times, respectively. Installing smoke exhaust systems above the fireplace can decrease indoor pollutant concentrations by more than 70%. The findings provide effective strategies for controlling health risks caused by indoor pollutants in winter without affecting local residents’ living habits and traditional customs.
Open AccessA Study on Indoor Air Quality in Traditional Earthen Residences of Western Hunan: Field Survey and Passive Mitigation Strategies
In the western Hunan region, the fire pit serves as the primary space for heating, receiving guests, and sacrificial ceremonies. However, the prolonged use of wood as the main fuel for the fire pit poses a significant threat to indoor air quality and the health of residents. This study conducts field monitoring and evaluation of indoor air quality in traditional earthen residences in Western Hunan during winter. It employs software simulation to analyze the concentration of indoor pollutants in typical earthen dwellings. Three passive mitigation strategies—adjusting window size, installing interior partitions, and setting up passive smoke exhaust systems—are proposed, and their effectiveness is validated through simulation. The results indicate that the best air circulation performance occurs when the window sill height is between 0.9 and 1.5 m, and the window sill length is between 1.5 and 2.1 m. Installing partitions increases the average concentration of indoor pollutants in the fire pit and master bedroom areas by 2.33 and 3.05 times, respectively. Installing smoke exhaust systems above the fireplace can decrease indoor pollutant concentrations by more than 70%. The findings provide effective strategies for controlling health risks caused by indoor pollutants in winter without affecting local residents’ living habits and traditional customs.