Meizhen Long
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Meizhen Long has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Lei Shi
School of Architecture and Art, Central South University, Changsha 410075, China
2 shared publications - Simian Liu
School of Architecture and Art, Central South University, Changsha 410075, China
2 shared publications - Fupeng Zhang
School of Architecture and Art, Central South University, Changsha, China
1 shared publication - Gaocheng Liang
School of Architecture and Art, Central South University, Changsha 410075, China
1 shared publication - Ming Luo
Hunan Key Laboratory of Low-Carbon Healthy Buildings, Central South University, Changsha 410083, China
1 shared publication - Ying Zhang
School of Architecture and Art, Central South University
1 shared publication
Latest Publications
- Open Access
A Study on Indoor Air Quality in Traditional Earthen Residences of Western Hunan: Field Survey and Passive Mitigation Strategies
In the western Hunan region, the fire pit serves as the primary space for heating, receiving guests, and sacrificial ceremonies. However, the prolonged use of wood as the main fuel for the fire pit poses a significant threat to indoor air quality and the health of residents. This study conducts field monitoring and evaluation of indoor air quality in traditional earthen residences in Western Hunan during winter. It employs software simulation to analyze the concentration of indoor pollutants in typical earthen dwellings. Three passive mitigation strategies—adjusting window size, installing interior partitions, and setting up passive smoke exhaust systems—are proposed, and their effectiveness is validated through simulation. The results indicate that the best air circulation performance occurs when the window sill height is between 0.9 and 1.5 m, and the window sill length is between 1.5 and 2.1 m. Installing partitions increases the average concentration of indoor pollutants in the fire pit and master bedroom areas by 2.33 and 3.05 times, respectively. Installing smoke exhaust systems above the fireplace can decrease indoor pollutant concentrations by more than 70%. The findings provide effective strategies for controlling health risks caused by indoor pollutants in winter without affecting local residents’ living habits and traditional customs.
Open AccessA Study on Indoor Air Quality in Traditional Earthen Residences of Western Hunan: Field Survey and Passive Mitigation Strategies
In the western Hunan region, the fire pit serves as the primary space for heating, receiving guests, and sacrificial ceremonies. However, the prolonged use of wood as the main fuel for the fire pit poses a significant threat to indoor air quality and the health of residents. This study conducts field monitoring and evaluation of indoor air quality in traditional earthen residences in Western Hunan during winter. It employs software simulation to analyze the concentration of indoor pollutants in typical earthen dwellings. Three passive mitigation strategies—adjusting window size, installing interior partitions, and setting up passive smoke exhaust systems—are proposed, and their effectiveness is validated through simulation. The results indicate that the best air circulation performance occurs when the window sill height is between 0.9 and 1.5 m, and the window sill length is between 1.5 and 2.1 m. Installing partitions increases the average concentration of indoor pollutants in the fire pit and master bedroom areas by 2.33 and 3.05 times, respectively. Installing smoke exhaust systems above the fireplace can decrease indoor pollutant concentrations by more than 70%. The findings provide effective strategies for controlling health risks caused by indoor pollutants in winter without affecting local residents’ living habits and traditional customs.
- Open Access
- 25 July 2025
- Published by MDPI AG in Sustainability
- Vol. 17 (15) , 6773
FDS-Based Study on Fire Spread and Control in Modern Brick-Timber Architectural Heritage: A Case Study of Faculty House at a University in Changsha
The modern Chinese architectural heritage combines sturdy Western materials with delicate Chinese styling, mainly adopting brick-timber structural systems that are highly vulnerable to fire damage. The study assesses the fire spread characteristics of the First Faculty House, a 20th-century architectural heritage located at a university in China. The assessment is carried out by analyzing building materials, structural configuration, and fire load. By using FDS (Fire Dynamics Simulator (PyroSim version 2022)) and SketchUp software (version 2023) for architectural reconstruction and fire spread simulation, explores preventive measures to reduce fire risks. The result show that the total fire load of the building amounts to 1,976,246 MJ. After ignition, flashover occurs at 700 s, accompanied by a sharp increase in the heat release rate (HRR). The peak ceiling temperature reaches 750 °C. The roof trusses have critical structural weaknesses when approaching flashover conditions, indicating a high potential for collapse. Three targeted fire protection strategies are proposed in line with the heritage conservation principle of minimal visual and functional intervention: fire sprinkler systems, fire retardant coating, and fire barrier. Simulations of different strategies demonstrate their effectiveness in mitigating fire spread in elongated architectural heritages with enclosed ceiling-level ignition points. The efficacy hierarchy follows: fire sprinkler system > fire retardant coating > fire barrier. Additionally, because of chimney effect, for fire sources located above the ceiling and other hidden locations need to be warned in a timely manner to prevent the thermal plume from invading other sides of the ceiling through the access hole. This research can serve as a reference framework for other Modern Chinese Architectural Heritage to develop appropriate fire mitigation strategies and to provide a methodology for sustainable development of the Chinese architectural heritage.
- 25 July 2025
- Published by MDPI AG in Sustainability
- Vol. 17 (15) , 6773
Open AccessFDS-Based Study on Fire Spread and Control in Modern Brick-Timber Architectural Heritage: A Case Study of Faculty House at a University in Changsha
The modern Chinese architectural heritage combines sturdy Western materials with delicate Chinese styling, mainly adopting brick-timber structural systems that are highly vulnerable to fire damage. The study assesses the fire spread characteristics of the First Faculty House, a 20th-century architectural heritage located at a university in China. The assessment is carried out by analyzing building materials, structural configuration, and fire load. By using FDS (Fire Dynamics Simulator (PyroSim version 2022)) and SketchUp software (version 2023) for architectural reconstruction and fire spread simulation, explores preventive measures to reduce fire risks. The result show that the total fire load of the building amounts to 1,976,246 MJ. After ignition, flashover occurs at 700 s, accompanied by a sharp increase in the heat release rate (HRR). The peak ceiling temperature reaches 750 °C. The roof trusses have critical structural weaknesses when approaching flashover conditions, indicating a high potential for collapse. Three targeted fire protection strategies are proposed in line with the heritage conservation principle of minimal visual and functional intervention: fire sprinkler systems, fire retardant coating, and fire barrier. Simulations of different strategies demonstrate their effectiveness in mitigating fire spread in elongated architectural heritages with enclosed ceiling-level ignition points. The efficacy hierarchy follows: fire sprinkler system > fire retardant coating > fire barrier. Additionally, because of chimney effect, for fire sources located above the ceiling and other hidden locations need to be warned in a timely manner to prevent the thermal plume from invading other sides of the ceiling through the access hole. This research can serve as a reference framework for other Modern Chinese Architectural Heritage to develop appropriate fire mitigation strategies and to provide a methodology for sustainable development of the Chinese architectural heritage.