Aarti Notnani
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Aarti Notnani has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Arshad Khan
Radiological Physics and Advisory Division, Bhabha Atomic Research Centre (BARC), Mumbai, India
2 shared publications - Nagesh Nagabhushana Bhat
Radiological Physics and Advisory Division, Bhabha Atomic Research Centre (BARC), Mumbai, India
2 shared publications - Rajesh Kumar Chaurasia
Radiological Physics and Advisory Division, Bhabha Atomic Research Centre (BARC), Mumbai, India
2 shared publications - Balvinder Kaur Sapra
Radiological Physics and Advisory Division, Bhabha Atomic Research Centre (BARC), Mumbai, India
1 shared publication Kapil B. Shirsath
Radiological Physics and Advisory Division, Bhabha Atomic Research Centre (BARC), Mumbai, India
1 shared publication- Kapil B. Shirsath
Radiological Physics and Advisory Division, Bhabha Atomic Research Centre (BARC), Mumbai, India
1 shared publication
Latest Publications
- Open Access
A Rare Constitutional Centromeric Expansion of Chromosome 1 in a Phenotypically Normal Individual: A Comprehensive Cytogenetic Study
Constitutional centromeric heteromorphisms are uncommon chromosomal variants that may complicate cytogenetic interpretation. We report a constitutional enlargement of the centromeric region of one chromosome 1 homologue identified incidentally during biological dose estimation in a suspected occupationally exposed individual. Conventional cytogenetics, pan-centromeric fluorescence in situ hybridization (FISH), and multiplex FISH confirmed the variant and excluded cryptic chromosomal rearrangements. Analysis of 500 metaphases revealed no dicentric chromosomes. Quantitative assessment demonstrated a centromere-to-chromosome length ratio of 0.314 ± 0.019 for the enlarged homologue compared with 0.169 ± 0.019 for the unaffected homologue and 0.161–0.186 in controls, representing an approximately 1.86-fold increase (t = 28.4, p < 0.0001). The findings establish a benign constitutional centromeric heteromorphism of chromosome 1 and highlight the importance of distinguishing such variants from structural chromosomal abnormalities during routine cytogenetic evaluation.
Open AccessA Rare Constitutional Centromeric Expansion of Chromosome 1 in a Phenotypically Normal Individual: A Comprehensive Cytogenetic Study
Constitutional centromeric heteromorphisms are uncommon chromosomal variants that may complicate cytogenetic interpretation. We report a constitutional enlargement of the centromeric region of one chromosome 1 homologue identified incidentally during biological dose estimation in a suspected occupationally exposed individual. Conventional cytogenetics, pan-centromeric fluorescence in situ hybridization (FISH), and multiplex FISH confirmed the variant and excluded cryptic chromosomal rearrangements. Analysis of 500 metaphases revealed no dicentric chromosomes. Quantitative assessment demonstrated a centromere-to-chromosome length ratio of 0.314 ± 0.019 for the enlarged homologue compared with 0.169 ± 0.019 for the unaffected homologue and 0.161–0.186 in controls, representing an approximately 1.86-fold increase (t = 28.4, p < 0.0001). The findings establish a benign constitutional centromeric heteromorphism of chromosome 1 and highlight the importance of distinguishing such variants from structural chromosomal abnormalities during routine cytogenetic evaluation.
- Open Access
- 2 June 2026
- Published by Springer Nature in Research Square
Establishment of a Dose-Response Curve for ⁶⁰Co γ-radiation-Induced Dicentric plus Ring Chromosomes: An Activity of the Indian Biodosimetry Network (IN-BioDoS)
Background: For precise biological dose measurement during radiation crises, a consistent dose-response curve for dicentric plus ring chromosomes caused by ionizing radiation must be established. This program, which is a part of the Indian Biodosimetry Network (IN-BioDoS), seeks to improve national capability for quick radiation dose estimation, strengthen interlaboratory readiness, and standardize cytogenetic biodosimetry procedures. Purpose: To construct a consistent cytogenetic dose–response curve for ⁶⁰Co γ-radiation utilizing dicentric plus ring chromosomes for reliable biodosimetry and emergency radiation dose assessment. Methods: , as the central coordinating laboratory, performed controlled irradiations (n = 4), followed by whole blood culture and metaphase slide preparation. The prepared slides were then transferred in a blinded manner to Nitte (Deemed to be University) for independent manual scoring under bright-field microscopy. Results: The resulting data were used to construct a dose-response calibration curve [Y = (0.029 ± 0.0006) *D + (0.043 ± 0.003) *D 2 + (0.0001 ± 0.0008)], with the derived coefficients falling within previously reported ranges. Validation using five blinded samples (0.1 - 4 Gy) demonstrated good agreement between estimated and delivered doses. All true doses fell within their respective 95% confidence intervals. Absolute deviations ranged from 0.039 to 0.366 Gy, with all estimates lying within ±0.5 Gy of the true dose. Relative accuracy analysis showed that 80% of estimates are within ±25% of the delivered dose, with the only larger deviation observed at 0.1 Gy (+39.0%), reflecting inherent limitations at very low dose levels. The overall mean absolute deviation was 0.174 Gy, indicating satisfactory accuracy for practical biodosimetry applications. These findings demonstrate the reliability of the established calibration curve for retrospective dose estimation, particularly in clinically relevant dose ranges. Conclusions: The study highlights the importance of methodological harmonization and collaborative frameworks within the IN-BioDoS network to strengthen national preparedness for radiation emergency response and to support informed decision-making in public health and radiation protection.
- 2 June 2026
- Published by Springer Nature in Research Square
Open AccessEstablishment of a Dose-Response Curve for ⁶⁰Co γ-radiation-Induced Dicentric plus Ring Chromosomes: An Activity of the Indian Biodosimetry Network (IN-BioDoS)
Background: For precise biological dose measurement during radiation crises, a consistent dose-response curve for dicentric plus ring chromosomes caused by ionizing radiation must be established. This program, which is a part of the Indian Biodosimetry Network (IN-BioDoS), seeks to improve national capability for quick radiation dose estimation, strengthen interlaboratory readiness, and standardize cytogenetic biodosimetry procedures. Purpose: To construct a consistent cytogenetic dose–response curve for ⁶⁰Co γ-radiation utilizing dicentric plus ring chromosomes for reliable biodosimetry and emergency radiation dose assessment. Methods: , as the central coordinating laboratory, performed controlled irradiations (n = 4), followed by whole blood culture and metaphase slide preparation. The prepared slides were then transferred in a blinded manner to Nitte (Deemed to be University) for independent manual scoring under bright-field microscopy. Results: The resulting data were used to construct a dose-response calibration curve [Y = (0.029 ± 0.0006) *D + (0.043 ± 0.003) *D 2 + (0.0001 ± 0.0008)], with the derived coefficients falling within previously reported ranges. Validation using five blinded samples (0.1 - 4 Gy) demonstrated good agreement between estimated and delivered doses. All true doses fell within their respective 95% confidence intervals. Absolute deviations ranged from 0.039 to 0.366 Gy, with all estimates lying within ±0.5 Gy of the true dose. Relative accuracy analysis showed that 80% of estimates are within ±25% of the delivered dose, with the only larger deviation observed at 0.1 Gy (+39.0%), reflecting inherent limitations at very low dose levels. The overall mean absolute deviation was 0.174 Gy, indicating satisfactory accuracy for practical biodosimetry applications. These findings demonstrate the reliability of the established calibration curve for retrospective dose estimation, particularly in clinically relevant dose ranges. Conclusions: The study highlights the importance of methodological harmonization and collaborative frameworks within the IN-BioDoS network to strengthen national preparedness for radiation emergency response and to support informed decision-making in public health and radiation protection.