Aldona Nowicka
Research Subjects
Aldona Nowicka has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
Aldona Kubala-Kukuś
1 shared publication- Andrzej Sierakowski
Institute of Microelectronics and Photonics, Łukasiewicz Research Network
1 shared publication Dariusz Banaś
1 shared publication- Dariusz Czułek
Central Office of Measures (GUM), ul. Elektoralna 2, 00-139 Warszawa, Poland
1 shared publication - Ilona Stabrawa
Institute of Physics, Jan Kochanowski University, Świętokrzyska 15, 25-406 Kielce, Poland
1 shared publication - Janusz D. Fidelus
Institute of Physics, Jan Kochanowski University, Uniwersytecka 7, 25-406 Kielce, Poland
1 shared publication
Latest Publications
- Open Access
- 5 June 2026
- Published by Elsevier in SSRN Electronic Journal
Fabrication and Metrological Validation of a Candidate AFM Calibration Standard Based on Silicon Nanostructures
This study presents the design, fabrication, and the AFM technique characterization of novel silicon-based periodic nanostructures intended as advanced calibration references for SPM lateral and vertical scaling. The samples were fabricated using electron beam lithography (EBL) to produce sub-micrometer structures (critical dimension: 250 nm half-pitch), resulting in raised (islands) or recessed (pits) SiO2 square arrays in silicon, with controlled height (depth) of 40 nm. The resulting structures were thoroughly characterized using the AFM technique. AFM measurements were preceded by an characterization of the commercial TGQ1 calibration sample (nominal values: period of 3.0 μm, structure size 1.5 μm and height 20 nm), which confirmed proper operation of the AFM system and demonstrated reliable measurement performance. The AFM analysis of the fabricated samples facilitated determining the X and Y spectral periods as well as its height (depth). The fabricated structures are characterized by very high repeatability of the periodic patterns, both the in the X and Y directions (standard deviation of the mean on the level 0.3-0.6 nm (island structure) and 0.3-3 nm (pit structure), as well as in height/depth (0.06-0.08 nm/0.02-0.05 nm). The AFM results applied to determine structural periodicity of the fabricated samples were further confirmed by the Scanning Electron Microscopy (SEM) measurements. These custom nanostructures demonstrate excellent dimensional stability, cleanability, and compatibility with the AFM technique, addressing key limitations of commercial standards. Furthermore, they offer a promising pathway toward more versatile, SI-traceable calibration artifacts for emerging high-resolution SPM applications in nanotechnology, materials science, and nanometrology.
- 5 June 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessFabrication and Metrological Validation of a Candidate AFM Calibration Standard Based on Silicon Nanostructures
This study presents the design, fabrication, and the AFM technique characterization of novel silicon-based periodic nanostructures intended as advanced calibration references for SPM lateral and vertical scaling. The samples were fabricated using electron beam lithography (EBL) to produce sub-micrometer structures (critical dimension: 250 nm half-pitch), resulting in raised (islands) or recessed (pits) SiO2 square arrays in silicon, with controlled height (depth) of 40 nm. The resulting structures were thoroughly characterized using the AFM technique. AFM measurements were preceded by an characterization of the commercial TGQ1 calibration sample (nominal values: period of 3.0 μm, structure size 1.5 μm and height 20 nm), which confirmed proper operation of the AFM system and demonstrated reliable measurement performance. The AFM analysis of the fabricated samples facilitated determining the X and Y spectral periods as well as its height (depth). The fabricated structures are characterized by very high repeatability of the periodic patterns, both the in the X and Y directions (standard deviation of the mean on the level 0.3-0.6 nm (island structure) and 0.3-3 nm (pit structure), as well as in height/depth (0.06-0.08 nm/0.02-0.05 nm). The AFM results applied to determine structural periodicity of the fabricated samples were further confirmed by the Scanning Electron Microscopy (SEM) measurements. These custom nanostructures demonstrate excellent dimensional stability, cleanability, and compatibility with the AFM technique, addressing key limitations of commercial standards. Furthermore, they offer a promising pathway toward more versatile, SI-traceable calibration artifacts for emerging high-resolution SPM applications in nanotechnology, materials science, and nanometrology.